Background: External rotation (ER) strengthening of the shoulder is an integral component of rehabilitative and preventative programs for overhead athletes. A variety of shoulder ER strengthening exercises are reported, including those intended to integrate the core musculature. The purpose of this study was to examine ER torque and electromyographic (EMG) activation of shoulder and trunk muscles while performing resisted isometric shoulder ER in 3 positions (standing, side lying, and side plank). Hypothesis: Significantly greater force and shoulder muscle activation would be generated while side lying given the inherent stability of the position, and greater trunk muscle activation would be generated in the less stable plank position. Study Design: Quasi-experimental repeated-measures study. Level of Evidence: Level 5. Methods: A convenience sample of 25 healthy overhead recreational athletes (9 men, 16 women) participated in this study. EMG electrodes were placed on the infraspinatus, posterior deltoid, middle trapezius, multifidi, internal obliques, and external obliques. EMG signals were normalized to a maximal isometric contraction. Participants performed resisted isometric ER in standing, side-lying, and side plank positions. Results were analyzed using a repeated-measures analysis of variance with post hoc Bonferroni corrections (α = 0.05). Results: There was no significant difference in ER torque between positions (α = 0.05). A significant difference in EMG activity of shoulder and trunk musculature between positions was found in 7 of the 8 muscles monitored. Significantly greater EMG activity in the infraspinatus, middle trapezius, and the nondominant external and internal obliques was found in the side plank position as compared with standing and side lying. Conclusion: While there was no difference in ER torque between the 3 exercise positions, EMG activity of the shoulder and trunk muscles was dependent on body position. Clinical Relevance: If a clinician is seeking to integrate trunk muscle activation while performing shoulder ER strengthening, the side plank position is preferred as compared with standing or side lying.
Interpreting oblique impact data from an accelerometer-instrumented ice hockey helmet
Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology | April 7, 2017 | Volume: 231 | Issue: 4 | Pages: 307-316
The purpose of this study was to assess the correlations of acceleration measurements between an instrumented hockey helmet and the Hybrid III headform and to determine whether collision with a broad surface affects the correlations between these data. A CCM Vector hockey helmet, instrumented with the Head Impact Telemetry System, was fitted onto an instrumented Hybrid III headform and dropped onto an inclined plate to simulate impacts in hockey. The helmet and headform were dropped from 0.15, 0.30, and 0.60 m at different orientations to create impacts to the vertex, occipital, right, left, and forehead surfaces. Peak linear and rotational acceleration magnitudes and head injury criteria were assessed for each system. Correlations were assessed with the Pearson correlation coefficient, and linear regression models were generated. Relative error was assessed, and results were compared with the Wilcoxon signed rank test. Peak acceleration magnitudes generally had strong mathematical correlations, although a 1:1 linear relationship for rotational acceleration data was not observed. Differences between helmet and head peak acceleration magnitudes were significant. The linear relationship varied according to the impact direction. Instrumented helmet and head data demonstrated a strong mathematical correlation, but measures of linear acceleration generally had better 1:1 agreement than rotational acceleration measures. There is some dependence in the relationship between the helmet and head data on the impact direction, with vertex strikes showing the weakest correlation. Although data generated from the helmet may be useful for interpreting head accelerations experienced by on-ice players, additional analysis of the time-series data should be performed to understand its full utility.
Does fair play reduce concussions? A prospective, comparative analysis of competitive youth hockey tournaments
Background/aim To determine if Boys Bantam and Peewee and Girls U14 sustain fewer concussions, head hits, ‘other injuries’ and penalties in hockey tournaments governed by intensified fair play (IFP) than non-intensified fair play (NIFP). Methods A prospective comparison of IFP, a behaviour modification programme that promotes sportsmanship, versus control (non-intensified, NIFP) effects on numbers of diagnosed concussions, head hits without diagnosed concussion (HHWDC), ‘other injuries’, number of penalties and fair play points (FPPs). 1514 players, ages 11–14 years, in 6 IFP (N=950) and 5 NIFP (N=564) tournaments were studied. Results Two diagnosed concussions, four HHWDC, and six ‘other injuries’ occurred in IFP tournaments compared to one concussion, eight HHWDC and five ‘other injuries’ in NIFP. There were significantly fewer HHWDC in IFP than NIFP (p=0.018). However, diagnosed concussions, ‘other injuries’, penalties and FPPs did not differ significantly between conditions. In IFP, a minority of teams forfeited the majority of FPPs. Most diagnosed concussions, HHWDC, and other injuries occurred to Bantam B players and usually in penalised teams that forfeited their FPPs. Conclusions In response to significant differences in HHWDC between IFP and NIFP tournaments, the following considerations are encouraged: mandatory implementation of fair play in regular season and tournaments, empowering tournament directors to not accept heavily penalised teams, and introducing ‘no body checking’ in Bantam.
Long‐term effect of a short interprofessional education interaction between medical and physical therapy students
AbstractPurposeAssessment of hip internal rotation (IR) is a critical element in the evaluation of a painful hip, yet there currently exists no consistent method of determining this measurement. The purpose of this study is to report the intra‐rater and inter‐rater reliability of active and passive hip IR measurement using a digital inclinometer.MethodsTwenty‐five subjects (8 men, 17 women) with asymptomatic hip joints, and no known pathology between the ages of 22 and 42 participated. Two examiners measured hip IR for each subject using a digital inclinometer while visually monitoring pelvic motion. Measurements included passive IR, active IR, and active IR while internally rotating both legs simultaneously. Statistical analysis was performed including intra‐rater and inter‐rater reliability.ResultsThere was no significant difference in measured IR values. Mean range of motion values for all techniques and both examiners ranged from 30.7° to 32.8°. Intra‐rater reliability for examiner 1 ranged from 0.84 to 0.92. Inter‐rater reliability ranged from 0.89 to 0.93. Of the methods utilized, active IR of a single leg was the most responsive technique with a minimal detectable change value of 5.4°.ConclusionsClinical assessment of hip IR range of motion can be performed efficiently and reliably with a digital inclinometer along with visual monitoring of the pelvis for unwanted motion. Findings from this study support unilateral active hip IR in a seated position as a reliable and responsive technique for obtaining hip IR measurements.Level of evidenceIII.
Use of individual feedback during human gross anatomy course for enhancing professional behaviors in doctor of physical therapy students
AbstractPurposeThe primary purpose of this study was to investigate the intra‐tester and inter‐tester reliability of the dial test using a handheld digital inclinometer. Additionally, we examined the responsiveness of the test, and side‐to‐side differences for meaningful comparison.Materials/methodsTwenty‐four healthy subjects (22.5 ± 2.8 years) participated in the study. The dial test was performed on both knees at 30° and 90° of knee flexion with the subject supine. While maintaining a neutral position of the ankle, an inclinometer was positioned parallel to the medial border of the foot to quantify external rotation of the tibia. Two examiners performed the dial test in a blinded manner. The minimal detectable change across repeated measures and side‐to‐side difference was calculated.ResultsIntra‐tester reliability for examiner 1 (E1) was 0.83 at 30° knee flexion and 0.89 at 90° knee flexion. Reliability values for examiner 2 (E2) were 0.86 at 30° and 0.87 at 90° knee flexion. Inter‐tester reliability was 0.74 at 30° and 0.83 at 90°. The minimal detectable change (MDC) for E1 at 30° was ±9.4° and ±7.4° at 90°. For E2, the MDC value was ±9.1° at 30° and ±8.3° at 90°. Ninety‐five percent limits of agreement for side‐to‐side difference was 16.1° and 11.3° ° for E1 at 30° and 90° and for E2 13.9° at 30° and 14.1° at 90°.ConclusionsThis instrumented dial test using a handheld digital inclinometer to measure external rotation can be performed with acceptable reliability in the clinical setting. A difference of 10° between two measurements on the same knee suggests that a meaningful change has occurred. For right to left comparison, differences greater than 15° suggest clinical significance.Level of evidenceIII.