Distal Access to Wide-Necked Aneurysms—‘Around the World’ Technique: 2-Dimensional Operative Video
Ringer, Andrew J. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael R. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Ogilvy, Christopher S. , Levitt, Michael R , Schirmer, Clemens M , Ogilvy, Christopher S , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E39-E40

10.1093/ons/opaa369 Get It

Abstract Wide-necked aneurysms often pose challenges for distal access to the distal vasculature. This 64-yr-old woman without neurological deficits presented with atypical headaches of gradual onset. MRI revealed a large, symptomatic, unruptured carotid terminus aneurysm incorporating the origin of both the middle (MCA) and anterior cerebral arteries (ACA). Its wide neck created significant risks to coil prolapse and parent vessel compromise, risking stroke. With other options of higher risks, we recommended an around-the-world technique. Standard transfemoral access was used to the right internal carotid artery (ICA) with a 6F-Shuttle sheath and intracranial carotid with a 6F-Sofia distal access catheter. With dual-microcatheter access, 1 catheter was placed in the aneurysm dome, a second in the MCA for stent placement. Advancing the wire around the aneurysm first formed a loop from the lateral to medial wall for access to the MCA. The microcatheter was then advanced around the wire into the MCA, keeping the loop within the dome. With the loop's distal tip anchored, the distal end of the stent was deployed and anchored into the MCA. Both pitfalls (ie, lack of sufficient distal access, collapse of stent device during deployment) were resolved using a balloon catheter. With the balloon positioned and inflated as the anchor, the wire and catheter were pulled together. The loop in the aneurysm's dome straightened out across the neck, the stent was advanced into the MCA, and coiling proceeded. A large neck remnant had partially closed on 6-mo follow-up angiogram. Patient consented to undergo the procedure. Illustrations in video published/printed with permission from Mayfield Clinic.
Stent-Assisted Coiling of a Sidewall Aneurysm of the Distal Middle Cerebral Artery: 2-Dimensional Operative Video
Cavalcanti, Daniel D. , Delavari, Nader , Riina, Howard A. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levy, Elad, Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Schirmer, Clemens M , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael R. , Levy, E, Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E37-E38

10.1093/ons/opaa332 Get It

Abstract Sidewall aneurysm treatment often requires complex management strategies. These can include advanced clipping techniques or stent-assisted coiling techniques. Endovascular coiling alone has been associated with high recurrence rates and is often not feasible. 1-4 Flow-diversion embolization has recently become a standard of care for many aneurysms, demonstrating high occlusion rates. 4,5 However, the third generation of coil-assist stents can be delivered with 0.0165” microcatheters, being an ideal adjunct to manage this group of aneurysms in more distal locations. In this video, a 16-yr-old teenager with Parry-Romberg syndrome and congenital adrenal hyperplasia had an incidental finding of a 6.5-mm sidewall aneurysm arising off the angular branch of the left middle cerebral artery, found during the work-up of complex partial seizures. The patient consented to the procedure. Due to his young age and aneurysm size, a decision was made to treat the aneurysm through an endovascular approach. Under general anesthesia, a transfemoral approach was carried out using a 6-French short sheath. A 6-French guiding catheter was left in the distal cervical left internal carotid artery; a 0.0165” microcatheter was used to first deploy a 3.0 × 15 mm Neuroform Atlas stent, completely covering the length of the aneurysm. Then, the stent was traversed with the microcatheter to coil the aneurysm. Follow-up cerebral angiogram confirmed complete occlusion of the aneurysm.
Preserving Olfactory Function in Anterior Craniofacial Surgery through Cribriform Plate Osteotomy Applied in Selected Patients
Feiz‐Erfan, Iman , Han, Patrick P., Spetzler, Robert F., Horn, Eric M., Klopfenstein, Jeffrey D., Kim, Louis J. , Porter, Randall W., Beals, Stephen P., Lettieri, Salvatore C. , Joganic, Edward F., Kim, Louis J.

Operative Neurosurgery | July 13, 2005 | Volume: 57 | Issue: suppl_1 | Pages: 86-93

10.1227/01.neu.0000163487.94463.4a Get It

AbstractOBJECTIVE:Olfaction is often sacrificed to gain access to the cranial base in anterior craniofacial surgery. We describe the long-term results of olfactory function in patients who underwent anterior craniofacial surgery and a cribriform plate osteotomy to preserve olfaction.METHODS:Between 1992 and 2004, 28 patients underwent 29 cribriform plate osteotomies in an attempt to preserve olfaction during anterior craniofacial surgery performed through modified extended transbasal approaches. Patients' charts and office notes were reviewed retrospectively. Formal olfactory testing was available in 5 patients, but most data were based on patients' subjective reports of olfaction. Olfactory preservation was defined by the subjective ability to detect fumes such as coffee, chocolate, roses, and orange juice regardless of the intensity of the sensation. Follow-up was based on phone calls to patients.RESULTS:Four patients were lost to follow-up and excluded. Therefore, follow-up was available in 24 patients after 25 procedures. On the basis of patients' subjective reports, olfaction was spared in 22 patients after 23 procedures (92%) and was confirmed objectively in the five patients formally tested. After surgery, only two patients were anosmic.CONCLUSION:Olfaction can be preserved in selected patients undergoing anterior craniofacial surgery. At least 1 cm of nasal mucosa should remain attached to the cribriform plate, which can be achieved by including the nasal bone in the osteotomy of the orbital bar. A medial orbital canthopexy is therefore necessary after these procedures.