Back to Authors

Sorajja, Paul

0000-0001-6401-854X

Mayo Clinic

Abbott Northwestern Hospital

Citations 42

Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention
Waterbury, Thomas M. , Sorajja, Paul , Bell, Malcolm R. , Lennon, Ryan J. , Mathew, Verghese, Sandhu, Gurpreet S. , Gulati, Rajiv , Sorajja, Paul , Singh, Mandeep

Catheterization and Cardiovascular Interventions | December 23, 2015 | Volume: 88 | Issue: 7 | Pages: 1057-1065

10.1002/ccd.26329 Get It

ObjectivesTo investigate the utility and safety of the GuideLiner “mother‐and‐child” catheter system during transradial and transfemoral percutaneous coronary intervention (PCI).BackgroundIn patients with complex coronary anatomy, stent delivery can be challenging and result in procedural failure and complications. The GuideLiner is a coaxial guide extension system designed to enable deep vessel engagement and facilitate device delivery. The purpose of this study was to evaluate procedural success and safety in a series of GuideLiner‐facilitated PCI.MethodsSingle center retrospective study of PCI utilizing the GuideLiner catheter between February 2010 and October 2014. Patients who underwent PCI without GuideLiner use during the same time period were used as controls for comparison.ResultsA total of 363 cases of GuideLiner‐facilitated PCI were identified from 6,088 unique PCI procedures performed during this same time period. Patients in the GuideLiner group were older (mean age 71.5 vs. 67.8, P < 0.001) and had more multivessel disease (72% vs. 63%, P = 0.001) compared with controls. Type C lesions were present in 78% of GuideLiner cases. Procedural success resulting in successful device delivery with the GuideLiner catheter was 80.2%. Stent deformation associated with GuideLiner use occurred in 2.2% (8/363), with the incidence of this complication decreasing over device iterations. Coronary dissection attributed to GuideLiner occurred in 3.3% (12/363) and became less frequent over the study period.ConclusionsIn this consecutive series of GuideLiner supported PCI, the guide extension system enabled procedural success in the majority. A decline in device‐associated complications over time may be attributed to operator learning curve, patient selection, and improvement in catheter design. © 2015 Wiley Periodicals, Inc.
Response to Letter Regarding Article, “Flow-Gradient Patterns in Severe Aortic Stenosis With Preserved Ejection Fraction: Clinical Characteristics and Predictors of Survival”
Eleid, Mackram F. , Sorajja, Paul , Malouf, Joseph F., Scott, C.G., Pellikka, Patricia A. , Scott, Chrisopher G, Sorajja, Paul , Michelena, Héctor I. , Pellikka, Patricia A

Circulation | July 28, 2014 | Volume: 130 | Issue: 5 | Pages: No page available

10.1161/circulationaha.114.009358 Get It

Response to Letters Regarding Article, “Systemic Hypertension in Low-Gradient Severe Aortic Stenosis With Preserved Ejection Fraction”
Eleid, Mackram F. , Sorajja, Paul , Borlaug, Barry A. , Nishimura, Rick A. , Sorajja, Paul , Borlaug, Barry A

Circulation | July 1, 2014 | Volume: 130 | Issue: 1 | Pages: No page available

10.1161/circulationaha.114.009350 Get It

Symptomatic Obstructive Hypertrophic Cardiomyopathy
Sorajja, Paul , Ommen, Steve R. , Sorajja, Paul , Nishimura, Rick A.

Circulation: Cardiovascular Interventions | October 16, 2013 | Volume: 6 | Issue: 5 | Pages: 586-591

10.1161/circinterventions.113.000581 Get It

Flow-Gradient Patterns in Severe Aortic Stenosis With Preserved Ejection Fraction
Eleid, Mackram F. , Sorajja, Paul , Malouf, Joseph F., Scott, Christopher G. , Pellikka, Patricia A. , Sorajja, Paul , Michelena, Héctor I. , Scott, Christopher , Pellikka, Patricia A

Circulation | September 19, 2013 | Volume: 128 | Issue: 16 | Pages: 1781-1789

10.1161/circulationaha.113.003695 Get It

Background— Among patients with severe aortic stenosis (AS) and preserved ejection fraction, those with low gradient (LG) and reduced stroke volume may have an adverse prognosis. We investigated the prognostic impact of stroke volume using the recently proposed flow-gradient classification. Methods and Results— We examined 1704 consecutive patients with severe AS (aortic valve area <1.0 cm 2 ) and preserved ejection fraction (≥50%) using 2-dimensional and Doppler echocardiography. Patients were stratified by stroke volume index (<35 mL/m 2 [low flow, LF] versus ≥35 mL/m 2 [normal flow, NF]) and aortic gradient (<40 mm Hg [LG] versus ≥40 mm Hg [high gradient, HG]) into 4 groups: NF/HG, NF/LG, LF/HG, and LF/LG. NF/LG (n=352, 21%), was associated with favorable survival with medical management (2-year estimate, 82% versus 67% in NF/HG; P <0.0001). LF/LG severe AS (n=53, 3%) was characterized by lower ejection fraction, more prevalent atrial fibrillation and heart failure, reduced arterial compliance, and reduced survival (2-year estimate, 60% versus 82% in NF/HG; P <0.001). In multivariable analysis, the LF/LG pattern was the strongest predictor of mortality (hazard ratio, 3.26; 95% confidence interval, 1.71–6.22; P <0.001 versus NF/LG). Aortic valve replacement was associated with a 69% mortality reduction (hazard ratio, 0.31; 95% confidence interval, 0.25–0.39; P <0.0001) in LF/LG and NF/HG, with no survival benefit associated with aortic valve replacement in NF/LG and LF/HG. Conclusions— NF/LG severe AS with preserved ejection fraction exhibits favorable survival with medical management, and the impact of aortic valve replacement on survival was neutral. LF/LG severe AS is characterized by a high prevalence of atrial fibrillation, heart failure, and reduced survival, and aortic valve replacement was associated with improved survival. These findings have implications for the evaluation and subsequent management of AS severity.
Systemic Hypertension in Low-Gradient Severe Aortic Stenosis With Preserved Ejection Fraction
Eleid, Mackram F. , Sorajja, Paul , Nishimura, Rick A. , Sorajja, Paul , Borlaug, Barry A.

Circulation | August 17, 2013 | Volume: 128 | Issue: 12 | Pages: 1349-1353

10.1161/circulationaha.113.003071 Get It

Background— Low-gradient severe aortic stenosis with preserved ejection fraction is an increasingly recognized entity, and symptomatic patients may benefit from aortic valve replacement. However, systemic hypertension frequently coexists with low-gradient severe aortic stenosis, which itself may cause elevated left ventricular (LV) filling pressures with resultant symptoms of dyspnea. Methods and Results— Symptomatic patients with hypertension (aortic systolic pressure >140 mm Hg) and low-gradient (mean gradient <40 mm Hg) severe aortic stenosis (aortic valve area <1 cm 2 ) with preserved ejection fraction (ejection fraction >50%) who underwent invasive hemodynamic catheterization of the left and right sides of the heart received infusion of intravenous sodium nitroprusside to reduce blood pressure and arterial afterload. At baseline, patients had severe hypertension (aortic systolic pressure, 176±26 mm Hg), pulmonary hypertension (mean pressure, 39±12 mm Hg), elevated LV end-diastolic pressure (19±5 mm Hg), and reduced stroke volume (33±8 mL/m 2 ). All measures of afterload were reduced with nitroprusside ( P <0.001 for all). Nitroprusside reduced mean pulmonary artery pressure (25±10 mm Hg) and LV end-diastolic pressure (11±5 mm Hg; P <0.001 for both compared with baseline). Aortic valve area (0.86±0.11 to 1.02±0.16 cm 2 ; P =0.001) and mean gradient (27±5 to 29±6 mm Hg; P =0.02) increased with nitroprusside. Conclusions— Systemic hypertension in low-gradient severe aortic stenosis with preserved ejection fraction is associated with elevated LV filling pressures and pulmonary hypertension. Treatment of hypertension with vasodilator therapy results in a lowering of the total LV afterload, with a decrease in LV filling pressures and pulmonary artery pressures. These findings have important implications for the management of patients with low-gradient severe aortic stenosis with preserved ejection fraction and hypertension.
Invasive Measures of Afterload in Low Gradient Severe Aortic Stenosis With Preserved Ejection Fraction
Eleid, Mackram F. , Sorajja, Paul , Nishimura, Rick A. , Borlaug, Barry A. , Sorajja, Paul

Circulation: Heart Failure | May 25, 2013 | Volume: 6 | Issue: 4 | Pages: 703-710

10.1161/circheartfailure.112.000164 Get It

Background— The pathophysiology of low flow, low gradient severe aortic stenosis (LGSAS) with preserved ejection fraction is poorly understood. It has been proposed that abnormalities of arterial circulation are a major contributor to this syndrome. Methods and Results— We invasively examined systemic arterial afterload (effective arterial elastance, Ea; total arterial compliance, Ca; and systemic vascular resistance index) in patients with LGSAS (mean gradient, <40 mm Hg; aortic valve area, <1.0 cm 2 ) and preserved ejection fraction (≥50%), and compared these findings with patients with high gradient (≥40 mm Hg) severe aortic stenosis (HGSAS) and moderate AS (mean gradient, <40 mm Hg; aortic valve area, >1.0 cm 2 ). Patients with LGSAS (n=36), HGSAS (n=31), and moderate AS (n=19) were similar with respect to age, sex, body size, symptoms, comorbidities, and ejection fraction. Aortic valve area was similar between groups with LGSAS and HGSAS, but the patients with LGSAS had reduced stroke volume index and cardiac index ( P =0.003 for both). In comparison with patients with HGSAS and moderate AS, measures of afterload, including Ea (4.02±0.98 versus 3.13±0.81 and 3.06±0.79 mm Hg·m 2 /mL; P <0.0001) and systemic vascular resistance index (3116±799 versus 2515±645 and 2380±546 dyn·s·m 2 /cm 5 ; P =0.001), were significantly higher in LGSAS, whereas Ca was lower (0.46±0.16 versus 0.57±0.13 and 0.59±0.19 mL/m 2 per mm Hg; P =0.002). All invasive measures of arterial afterload were related to stroke volume index. Conclusions— Patients with LGSAS and preserved ejection fraction display elevated arterial afterload compared with patients with HGSAS and moderate AS. These findings identify systemic arterial effects that contribute to the hemodynamic presentation in patients with LGSAS and help to further define this entity.
Transcatheter Aortic Valve Insertion Catastrophe in Inoperable Patients: Should Aortic Valve Replacement Be Denied?
Greason, Kevin L. , Bresnahan, John F., Sorajja, Paul , Suri, Rakesh M. , Rihal, Charanjit S. , Mathew, Verghese, Sorajja, Paul , Rihal, Charanjit S.

Journal of Cardiac Surgery | May 16, 2013 | Volume: 28 | Issue: 4 | Pages: 336-338

10.1111/jocs.12127 Get It

A percutaneous solution for a percutaneous problem
Sorajja, Paul , Sorajja, Paul

Catheterization and Cardiovascular Interventions | March 23, 2013 | Volume: 81 | Issue: 5 | Pages: 906-907

10.1002/ccd.24900 Get It

High Sensitivity C-Reactive Protein and Outcomes Following Percutaneous Coronary Intervention in Contemporary Practice
Herrmann, Joerg , Lennon, Ryan J. , Barsness, Gregory W. , Sandhu, Gurpreet S. , Gulati, Rajiv , Best, Patricia J.M. , Sorajja, Paul , Bresnahan, John F., Mathew, Verghese, Bell, Malcolm R. , Prasad, Abhiram , Sorajja, Paul , Prasad, Abhiram

Circulation: Cardiovascular Interventions | December 5, 2012 | Volume: 5 | Issue: 6 | Pages: 783-790

10.1161/circinterventions.112.972182 Get It

Background— High sensitivity C-reactive protein (hsCRP) has been identified as a predictor of adverse cardiovascular outcomes. Whether hsCRP is a useful biomarker for risk stratification in contemporary percutaneous coronary intervention remains unknown. Methods and Results— We conducted a prospective study among 513 patients undergoing non-emergency percutaneous coronary intervention and examined the relationship between pre- and postprocedural hsCRP levels and outcomes. The patients were divided according to the median preprocedural hsCRP level (0.3 mg/dL). Patients with high hsCRP had significantly more adverse clinical characteristics. Preprocedural hsCRP level was an independent predictor of periprocedural myocardial infarction (odds ratio per doubling of hsCRP 1.15 [95% confidence interval, 1.01–1.31]; P =0.038). Unadjusted mortality (29.7% versus 9.9%; P <0.001) and the combined end point of death or myocardial infarction (36.5% versus 16.0%, P <0.001) during a follow-up of 5 years were markedly greater in patients with high preprocedural hsCRP. Similar relationships existed for postprocedural hsCRP. However, after multivariable adjustment, neither preprocedural hsCRP levels (hazard ratio per doubling 0.96 [0.92, 1.00]; P =0.066) nor postprocedural hsCRP levels (hazard ratio 0.98 [0.94, 1.02]; P =0.27) were significantly associated with mortality. Conclusions— High hsCRP is associated with a greater independent risk of periprocedural myocardial infarction, as defined by the universal definition, but is not an independent determinant of mortality after percutaneous coronary intervention. Our findings suggest that routine measurement of hsCRP in patients undergoing percutaneous coronary intervention in contemporary practice is unlikely to be beneficial.