Transapical versus transfemoral approach and risk of acute kidney injury following transcatheter aortic valve replacement: a propensity-adjusted analysis
Background— Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. Methods and Results— We retrospectively screened 794 transvenous lead extraction procedures, between September 1, 2001 and August 31, 2012, at Mayo Clinic to identify patients with prosthetic valves who underwent lead extraction for infection. Demographic, clinical, and follow-up characteristics were analyzed. In total, 51 patients (6%) met the study inclusion criteria, of whom 20 had pocket infection and 31 had lead-related or valve-related, or both, endocarditis or bloodstream infection (mean age, 67 [18] years). Staphylococcal species were the most common pathogens, including Staphylococcus aureus in 20 cases (39%) and coagulase-negative staphylococci in 19 cases (37%). Overall, 127 transvenous leads (median lead age, 52 months) were extracted. Of these leads, 123 (97%) were removed completely. The in-hospital mortality rate was 9.8%; no deaths were attributable to the extraction procedure. Ninety-five percent of patients who survived had no evidence of recurrent device-related or valve-related infection. Conclusions— Transvenous lead extraction seems safe and curative in patients with CIED infection and prosthetic valves. Cure of infection can be achieved in the majority of patients with complete CIED removal and antimicrobial therapy and without valve surgery.
One-Year Clinical Outcomes With SAPIEN 3 Transcatheter Aortic Valve Replacement in High-Risk and Inoperable Patients With Severe Aortic Stenosis
Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.
The effects of contrast media volume on acute kidney injury after transcatheter aortic valve replacement: a systematic review and meta‐analysis
AbstractObjectiveThe goal of this systematic review was to assess the effects of contrast media volume on transcatheter aortic valve replacement‐related acute kidney injury.MethodsA literature search was performed using Medline, EMbase, the Cochrane Database of Systematic Reviews, and clinicaltrials.gov from the inception of these databases through December 2015. Studies that reported relative risk, odds ratio, or hazard ratio comparing the risks of acute kidney injury following transcatheter aortic valve replacement in patients who received high contrast media volume were included. Pooled risk ratio (RR) and 95% confidence intervals (95% CI) were calculated using a random‐effect, generic inverse variance method.ResultsFour cohort studies composed of 891 patients were included in the analyses to assess the risk of acute kidney injury after transcatheter aortic valve replacement in patients who received high contrast media volume. The pooled RR of acute kidney injury after transcatheter aortic valve replacement in patients who received a large volume of contrast media was 1.41 (95% CI, 0.87 to 2.28) compared with low contrast media volume. The meta‐analysis was limited to studies using standard acute kidney injury definitions, and the pooled RR of acute kidney injury in patients who received high contrast media volume is 1.12 (95% CI, 0.78 to 1.62).ConclusionOur meta‐analysis shows no significant association between contrast media volume and risk of acute kidney injury after transcatheter aortic valve replacement.
Assisted care as a baseline patient risk characteristic affecting the outcome of transcatheter aortic valve insertion
AbstractAimThis study aimed to determine the incidence and risk factors of acute kidney injury (AKI) following transcatheter aortic valve replacement (TAVR).MethodsWe included all adult patients undergoing TAVR for aortic stenosis from 1 January 2008 to 30 June 2014 at a tertiary referral hospital. AKI was defined based on Kidney Disease: Improving Global Outcomes criteria. We performed a multivariate logistic regression to identify factors associated with post‐procedural AKI occurrence.ResultsThree hundred eighty‐six patients met the inclusion criteria, of which 106 (28%) developed AKI. In multivariate analysis, AKI development was independently associated with a transapical approach (odds ratio (OR), 2.81; 95% confidence interval (CI), 1.72–4.65 compared with transfemoral approach) and the need for an intra‐aortic balloon pump (OR, 9.11; 95% CI, 1.77–68.29). Higher baseline renal function (OR, 0.78 per 10 mL/min per 1.73 m2 increment in glomerular filtration rate; 95% CI, 0.68–0.87) was significantly associated with a decreased risk of AKI. After adjustment for the Society of Thoracic Surgeons' risk score, post‐procedural AKI development remained significantly associated with an increased in‐hospital (OR, 4.74; 95% CI, 1.39–18.48) and 6‐month mortality (OR, 4.66; 95% CI, 2.32–9.63).ConclusionIn a cohort of patients undergoing TAVR for aortic stenosis, AKI commonly occurred and was significantly associated with increased mortality. Baseline renal function, procedure approach and the need for circulatory support were important predictive factors for post‐procedural AKI occurrence.
AKI after Transcatheter or Surgical Aortic Valve Replacement
Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) for patients with symptomatic severe aortic stenosis who are at high risk of perioperative mortality. Previous studies showed increased risk of postoperative AKI with TAVR, but it is unclear whether differences in patient risk profiles confounded the results. To conduct a propensity-matched study, we identified all adult patients undergoing isolated aortic valve replacement for aortic stenosis at Mayo Clinic Hospital in Rochester, Minnesota from January 1, 2008 to June 30, 2014. Using propensity score matching on the basis of clinical characteristics and preoperative variables, we compared the postoperative incidence of AKI, defined by Kidney Disease Improving Global Outcomes guidelines, and major adverse kidney events in patients treated with TAVR with that in patients treated with SAVR. Major adverse kidney events were the composite of in-hospital mortality, use of RRT, and persistent elevated serum creatinine ≥200% from baseline at hospital discharge. Of 1563 eligible patients, 195 matched pairs (390 patients) were created. In the matched cohort, baseline characteristics, including Society of Thoracic Surgeons risk score and eGFR, were comparable between the two groups. Furthermore, no significant differences existed between the TAVR and SAVR groups in postoperative AKI (24.1% versus 29.7%; P =0.21), major adverse kidney events (2.1% versus 1.5%; P =0.70), or mortality >6 months after surgery (6.0% versus 8.3%; P =0.51). Thus, TAVR did not affect postoperative AKI risk. Because it is less invasive than SAVR, TAVR may be preferred in high-risk individuals.
Learning curves for transfemoral transcatheter aortic valve replacement in the PARTNER‐I trial: Success and safety