Back to Authors

Haas, Garrie J.

https://orcid.org/0000-0002-4189-6136

Mayo Clinic

The Ohio State University

Citations 2

A Phase 2A Dose-Escalation Study of the Safety, Tolerability, Pharmacokinetics and Haemodynamic Effects of BMS-986231 in Hospitalized Patients with Heart Failure with Reduced Ejection Fraction
Tita, Cristina , Gilbert, Edward M. , Bakel, Adrian B. Van , Grzybowski, Jacek , Haas, Garrie J. , Dunlap, Stephanie H., Klapholz, Marc, Patel, Parag C. , Pfister, Roman , Seidler, Tim , Shah, Keyur B. , Zieliński, Tomasz , Venuti, Robert, Cowart, Douglas, Foo, Shi Yin, Vishnevsky, A. A., Jarrah, Mohammad , Gottlieb, Stephen S. , Mitrović, Veselin L.

European Journal of Heart Failure | July 5, 2017 | Volume: 19 | Issue: 10 | Pages: 1321-1332

10.1002/ejhf.897 Get It

Abstract Aims This study was designed to evaluate the safety, tolerability and haemodynamic effects of BMS-986231, a novel second-generation nitroxyl donor with potential inotropic, lusitropic and vasodilatory effects in patients hospitalized with decompensated heart failure and reduced ejection fraction (HFrEF). Methods and results Forty-six patients hospitalized with decompensated HFrEF were enrolled into four sequential dose-escalation cohorts in this double-blind, randomized, placebo-controlled Phase 2a study. Patients with baseline pulmonary capillary wedge pressure (PCWP) of ≥20 mmHg and a cardiac index of ≤2.5 L/min/m2 received one 6-h i.v. infusion of BMS-986231 (at 3, 5, 7 or 12 µg/kg/min) or placebo. BMS-986231 produced rapid and sustained reductions in PCWP, as well as consistent reductions in time-averaged pulmonary arterial systolic pressure, pulmonary arterial diastolic pressure and right atrial pressure. BMS-986231 increased non-invasively measured time-averaged stroke volume index, cardiac index and cardiac power index values, and decreased total peripheral vascular resistance. There was no evidence of increased heart rate, drug-related arrhythmia or symptomatic hypotension with BMS-986231. Analyses of adverse events throughout the 30-day follow-up did not identify any toxicities specific to BMS-986231, with the potential exception of infrequent mild-to-moderate headaches during infusion. There were no treatment-related serious adverse events. Conclusions BMS-986231 demonstrated a favourable safety and haemodynamic profile in patients hospitalized with advanced heart failure. Based on preclinical data and these study's findings, it is possible that the haemodynamic benefits may be mediated by inotropic and/or lusitropic as well as vasodilatory effects. The therapeutic potential of BMS-986231 should be further assessed in patients with heart failure.
Secular Trends in Cardiac Transplant Recipient and Donor Management in the United States, 1990 to 1994
Rodeheffer, Richard J. , Naftel, David C., Stevenson, Lynne W. , Porter, Charles , Miller, Leslie W., Kenzora, Joseph L., Haas, Garrie J. , Bourge, Robert C. , Mehra, Mandeep R. , Young, James B. , Kirklin, James K. , Mehra, Mandeep R

Circulation | June 12, 2012 | Volume: 94 | Issue: 11 | Pages: 2883-2889

10.1161/01.cir.94.11.2883 Get It

Background The growth of the US cardiac transplant waiting list has outpaced the increase in donors, resulting in a widening gap between the number of waiting recipients and available donors. These trends have generated concern that longer waiting times may result in more patients deteriorating to urgent status and that transplanting only patients who are in an advanced state of decompensation will reduce posttransplant survival. Furthermore, the shortage of donors may result in extending the guidelines for donor acceptability to a degree that increases graft failure and posttransplant mortality. We measured these secular trends in the Cardiac Transplant Research Database to provide current data on time-dependent changes in US cardiac transplant practice and survival. Methods and Results At the time of this analysis, the Cardiac Transplant Research Database included all 2749 patients transplanted from January 1, 1990, to June 30, 1994, in the 25 participating transplant centers. During this 4.5-year period, the median waiting time for recipients who received a transplant increased from 2.7 to 3.5 months ( P <.0001), and the proportion of recipients whose status was urgent at transplantation increased from 41% to 60% ( P <.0001). Donor ischemic time increased from 150 to 166 minutes ( P <.0001), and the proportion of donors requiring pressor support increased from 68% to 85% ( P <.0001). Despite these changes in practice, the 1-year survival rate remained constant at 84% during this 4.5-year interval. There was no significant difference in 1-year survival rate between urgent status patients (83%) and nonurgent status patients (85%) ( P =.08). Conclusions The widening gap between the number of waiting recipients and the number of donors has resulted in a continuing trend toward transplanting urgent status recipients and to a liberalization of donor acceptance criteria. Despite these changes, posttransplant survival has remained constant.