Back to Authors

Banerjee, Imon

Mayo Clinic

Mayo Clinic Hospital

Citations 1

Beyond Doppler: Scalable AI Detection of LVOT Obstruction in HCM
Crystal, Owen , Farina, Juan Maria M, Scalia, Isabel G. , Ayoub, C A, Park, H B, Arsanjani, R A, Lester, Steven J, Banerjee, Imon, Arsanjani, Reza , Park, Hyung‐Bok , Arsanjani, Reza , Scalia, Isabel G , Park, Hyung Bok , Farina, Juan M. , Etchegoyen, Cecilia Villa , Chollet, Laurève , Kim, Kyung An , Lester, Steven J., Banerjee, Imon

No container title available | April 20, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.17.26351151 Get It

Abstract Background Accurate assessment of left ventricular outflow tract (LVOT) gradients is critical for hypertrophic cardiomyopathy (HCM) management, yet Doppler-based measurements are technically demanding and require expertise. Objective To develop a multi-view deep learning model capable of classifying LVOT obstruction (> 20mmHg) using routine 2D echocardiographic windows without reliance on Doppler imaging. Methods We trained and externally validated a cross-attention-based video-to-video fusion framework that integrated EchoPrime-derived video representations from three standard transthoracic echocardiographic views to classify LVOT gradients. Results Training was performed on a derivation cohort (N = 1833) from a tertiary care system in the United States, with model performance evaluated on an internal held-out test set (N = 275) and a Korean external validation cohort (N = 46). Single-view baselines showed limited discrimination (external AUROCs 0.47–0.70). Conversely, domain-specific foundational model (EchoPrime) achieved superior single-view performance (AUROCs 0.75–0.80 internal; 0.79–0.83 external), highlighting the importance of echo-specific pretraining and temporal modeling. The proposed multi-view fusion further enhanced predictive performance, with the late fusion model reaching an AUROC of 0.84 on the external cohort with significant population-shift. Conclusions These results suggest LVOT physiology is encoded in routine 2D imaging and can be leveraged for clinically relevant gradient classification without Doppler input- proposed AI-guided strategy demonstrates substantial cost savings compared with the screen-all approach. By integrating complementary spatial-temporal information across multiple views, our approach generalizes robustly across populations and may enable real-time decision support, extend LVOT assessment to portable or resource-limited settings, and complement Doppler-based evaluation for longitudinal HCM management.