Back to Authors

Medero, Ramon Correa

Mayo Clinic

Mayo Clinic in Arizona

Citations 2

Abstract 2779: Development and evaluation of a MIRAI 5-year risk model with a breast cancer polygenic risk score.
Scott, C, Kraft, Peter, Banerjee, Imon, Medero, Ramon Correa, Couch, Fergus J., Vachon, Celine M., Scott, Christopher G. , Banerjee, Imon , Correa, Ramón , Norman, Aaron D. , Couch, Fergus J. , Kerlikowske, Karla , Winham, Stacey J.

Cancer Research | April 3, 2026 | Volume: 86 | Issue: 7_Supplement | Pages: 2779-2779

10.1158/1538-7445.am2026-2779 Get It

Abstract Artificial intelligence (AI)-scores estimated from digital mammograms predict future breast cancer (BC) risk. MIRAI is a deep learning BC risk model that provides a continuous 5-year risk of overall BC from four screening full field digital mammograms. Common germline genetic variation in the form of a polygenic risk score (BC-PRS) is associated with increased BC risk and may improve MIRAI’s 5-year risk prediction. Our goal was to develop an updated MIRAI 5-year risk model that incorporates the BC-PRS (MIRAI+PRS) and to evaluate its discriminatory accuracy and calibration for both overall and invasive BC compared to MIRAI alone. We developed the MIRAI+PRS model by multiplying each woman’s 5-year MIRAI risk estimate by their relative risk based on their BC-PRS relative to the population mean. We evaluated the models within the Mayo Clinic Biobank mammography cohort, comprised of 12,307 women without a prior history of BC; 176 invasive and 250 overall BC were diagnosed within 5 years. MIRAI was estimated on screening mammograms closest to enrollment but at least 6 months prior to BC. Discriminatory accuracy, assessed by C-statistic, was high and similar for MIRAI+PRS vs. MIRAI models, for overall BC and invasive BC (Table). Calibration assessed by observed to expected (O/E) ratios was also similar for MIRAI+PRS compared to MIRAI predictions for BC outcomes (Table), although there was improvement in decile-specific O/E ratios across the lowest risk deciles (<1.67%) for MIRAI+PRS. Calibration for invasive cancer was poor for MIRAI with or without PRS. In summary, the MIRAI+PRS risk model did not result in significant difference of discriminatory accuracy or overall calibration compared to the MIRAI model, but there was evidence for improved calibration for women with 5-year risk below 1.67%. For invasive BC, the model had poor calibration regardless of whether PRS was included, underscoring the importance of training AI models for BC outcomes that are associated with a clinical intervention. Citation Format: Christopher G. Scott, Peter Kraft, Imon Banerjee, Ramon Correa Medero, Aaron D. Norman, Fergus J. Couch, Karla Kerlikowske, Stacey J. Winham, Celine M. Vachon. Development and evaluation of a MIRAI 5-year risk model with a breast cancer polygenic risk score [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 2779.
Performance of clinical breast cancer risk prediction models vs a mammography-based artificial intelligence risk model
Kaul, M., Scott, C., Wadzinske, Alena , Banerjee, Imon, Hursh, Dan, Norman, Aaron, Wu, Fang-Fang, Medero, Ramon Correa, Couch, Fergus, Pruthi, Sandhya , Olson, JA, Kerlikowske, Karla, Vachon, Celine M, Scott, Christopher G. , Couch, Fergus J. , Norman, Aaron D. , Banerjee, Imon , Correa, Ramón , Couch, Fergus J. , Kaul, Medha , Scott, Christopher , Banerjee, Imon , Norman, Aaron D , Correa-Medero, Ramon Luis , Kontos, Despina , McCarthy, Anne Marie , Winham, Stacey J , Kerlikowske, Karla M , Vachon, Celine M. , Pruthi, Sandhya , Hursh, Dan, Winham, Stacey J. , Kerlikowske, Karla

JNCI: Journal of the National Cancer Institute | March 24, 2026 | Volume: 118 | Issue: 8 | Pages: 1485-1495

10.1093/jnci/djag083 Get It

Abstract Background Artificial intelligence (AI)–based, mammography breast cancer risk prediction models show improved discriminatory accuracy relative to clinical risk models. However, data on their calibration are limited. This study compared model performance of 3 clinical breast cancer risk models: Gail, Tyrer–Cuzick v8, and Breast Cancer Surveillance Consortium v3 with the MIRAI AI-risk model. Methods Digital mammograms were ascertained from a screening mammography cohort of 12 308 women within the Mayo Clinic Biobank with 250 incident breast cancers (176 invasive) within 5 years. We predicted 5-year breast cancer risk, estimated discriminatory accuracy (C-index), and calibration (observed-to-expected ratio) of both overall and invasive breast cancer and compared estimates using bootstrapping approaches. Results MIRAI demonstrated similar or improved discriminatory accuracy of overall breast cancer (C-index = 0.71, 95% confidence interval [CI] = 0.68 to 0.74) and invasive breast cancer (C-index = 0.71, 95% CI = 0.67 to 0.75) compared with clinical models (overall breast cancer: C-index = 0.59-0.68; invasive breast cancer: C-index = 0.60-0.68). MIRAI’s calibration for risk of overall breast cancer (observed-to-expected ratio = 0.96, 95% CI = 0.85 to 1.08) was improved compared with Gail (observed-to-expected ratio = 1.22, 95% CI = 1.07 to 1.38) and Breast Cancer Surveillance Consortium (observed-to-expected ratio = 1.38, 95% CI = 1.22 to 1.56) but similar to TC with volumetric percent density and polygenic risk score (observed-to-expected ratio = 0.99, 95% CI = 0.87 to 1.13). However, for low-risk women (approximately 50%), MIRAI overestimated risk of overall breast cancer. MIRAI also overestimated risk of invasive breast cancer across the risk spectrum (observed-to-expected ratio = 0.68, 95% CI = 0.58 to 0.78), whereas clinical models had good calibration (observed-to-expected ratio = 0.86–0.99). Conclusion MIRAI demonstrated stronger discriminatory accuracy than clinical models for 5-year overall and invasive breast cancer risk prediction but overestimated risk for both breast cancer endpoints. AI-based risk models should consider discriminatory accuracy and calibration for invasive cancer before implementation.