Back to Authors

Erwin, William D.

https://orcid.org/0000-0003-2533-5838

Mayo Clinic

The University of Texas MD Anderson Cancer Center

Citations 6

AAPM Task Group No. 249.B—Essentials and guidelines for clinical medical physics residency training programs
Nye, Jonathon A. , Dugas, Joseph P., Erwin, William D. , Gierga, David P., Kaurin, D.G., Leon, Stephanie , Liu, Ho‐Ling , Lu, Zheng Feng , Magri, Alphonso, Rill, Lynn, Schubert, Leah , Schueler, Beth A. , Vergalasova, Irina , Vetter, John, Wichman, Brian, Yu, Amy S. , Leon, Stephanie M , Liu, Ho-Ling Anthony , Yu, Amy Shu-Jung , Zheng, Dandan , Zheng, Dandan

Journal of Applied Clinical Medical Physics | May 19, 2025 | Volume: 26 | Issue: 6 | Pages: No page available

10.1002/acm2.70111 Get It

Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies. The rapid growth of medical physics requires periodic review of the curriculum to remove outdated approaches, update established knowledge, and add emerging technologies. The goal of this document is to provide a reference standard for residency training program directors, training mentors, and residents to guide creation and/or optimization of their program's curriculum. The document is intentionally forward‐looking to capture emerging technological advances including hybrid diagnostic and therapeutic delivery systems and applications of image processing. This document is an update of the current residency training curriculum. Version history of residency training guidelines Publication Title Date 2013 Essentials and Guidelines for Clinical Medical Physics Residency Training Programs—AAPM Report No. 249 2006 Essentials and Guidelines for Hospital‐Based Medical Physics Residency Training Programs—Report No. 90 1992 Essentials and Guidelines for Hospital‐Based Medical Physics Residency Training Programs—Report No. 36 The Work Group on Periodic Review of Medical Physics Residency Training (WGMPRT) would like to acknowledge the authors of past versions of this document as they form the basis for this update. It is the sincere hope of the WGMPRT that this report will continue to be used by the medical physics community to guide training in the profession.
Understanding entrance‐air‐kerma as a quality‐control metric for dual‐energy x‐ray absorptiometry
Jimenez, Jorge E. , Fahrenholtz, Samuel J. , Hamdani, Khushnood, Erwin, William D. , Fahrenholtz, Samuel John, Thomas, Matthew Allan

Journal of Applied Clinical Medical Physics | September 4, 2022 | Volume: 23 | Issue: 10 | Pages: No page available

10.1002/acm2.13779 Get It

AbstractPurposeThe low exposures, unique x‐ray beam geometry, and scanning design in dual‐energy x‐ray absorptiometry (DXA) make measurement and quality‐control strategies different from traditional x‐ray equipment. This study examines the dependence of measured entrance‐air‐kerma (EAK) on both dose sensor type and scan length. The feasibility of using EAK to compare scanner output between different scan modes, individual scanners, and scanner platforms was also established. Finally, the congruence between measured and vendor‐reported EAK was analyzed.MethodsFour Hologic DXA scanners at two institutions and all four available scan modes were tested. EAK was measured directly by three types of Radcal dose sensors: 60‐cc pancake ion‐chamber (IC), 180‐cc pancake IC, and solid‐state detector. The coefficient of variation (COV) was used to assess the dependence of EAK on scan length. Variations in EAK between the types of dose sensors as well as measured versus vendor‐reported values were evaluated using Bland–Altman analysis: mean ±95% prediction interval (PI): 1.96σ.ResultsDose sensor variations in EAK were minimal, with a −3.5 ± 3.5% (mean ±95% PI) percent difference between the two sizes of IC's. The solid‐state detector produced highly similar measurements to the 180‐cc IC. These small differences were consistent across all scanners and all scan modes tested. Neither measured nor vendor‐reported EAK values were found to show relevant dependence on scan length, with all COV values ≤4%. Differences between measured and reported EAK were higher at −6 ± 48%. Likely errors in vendor‐reported EAK calculations were also identified.ConclusionIt is feasible to quantify DXA scanner stability using EAK as a quality‐control metric with a variety of solid‐state and IC dose sensors, and the scan length used is not critical. Although vendor‐reported EAK was consistent among scanners of the same platform, measured EAK varied significantly from scanner to scanner. As a result, measured and reported EAK may not always be comparable.
90Y Ibritumomab Tiuxetan (Zevalin®; 90YZ) Doses Higher Than .4 mCi/kg May Be Safely Combined with High-Dose Beam and Autotransplant: The Role for Dosimetry.
Inwards, David J. , Spies, Stewart, Wiseman, Gregory A., Erwin, William D. , Rademaker, Alfred , Williams, Stephanie , Tallman, Martin S. , Micallef, Ivana N. , Mehta, Jayesh, Zimmer, Michael, Molina, Arturo , Winter, Jane N. , Patton, David R. , Singhal, Seema , Zimmer, Michael, White, Christine, Gordon, Leo I.

Blood | April 18, 2020 | Volume: 104 | Issue: 11 | Pages: 1162-1162

10.1182/blood.v104.11.1162.1162 Get It

Abstract Twenty-eight patients with relapsed or refractory CD20+ NHL have been enrolled in an ongoing phase I trial of dose-escalated 90YZ followed by high-dose BEAM and autotransplant in which the 90YZ dose is patient-specific based on dosimetry. 90YZ doses are calculated to deliver cohort-defined radiation doses (100, 300, 500, ... cGy) to critical organs (liver, lung or kidney), with 3–6 patients per group. On D -22, rituximab (R) 250 mg/m2 is infused followed by the imaging dose of 111In Zevalin® (5 mCi). Imaging is performed immediately post-injection and at 4, 24, 72, and 144 hours; dosimetry is performed on D -15. On D -14, R 250 mg/m2 is administered followed immediately by 90YZ at the dose calculated to deliver the cohort-prescribed absorbed radiation dose to the critical organ. On D -6 through -1, patients receive high-dose BEAM. On D0, a minimum of 2.0 X 106 CD34+ cells/kg is infused and G-CSF 5 μg/kg SQ daily begun. The median age was 54 (range: 25–72) years. NHL histologic subtypes were as follows: mantle cell 5, diffuse aggressive 13, low grade 5, and transformed 5. Most had received 3 or more treatment regimens, including R. The toxicity profile was similar to that associated with high-dose BEAM and included a decrease in DLCO for most patients with one patient at the 500 cGy dose level experiencing a transient decline to below 50% of the predicted value corrected for hemoglobin. The most common grade III/IV toxicities were infection, fever, stomatitis, nausea, vomiting, diarrhea, hemorrhage, and edema. One patient experienced transient veno-occlusive disease at the 700 cGy dose level. Engraftment occurred at a median of 10 days (range:8–18) to granulocytes ≥ 500/μL, and 21 days (range:13–40days) to platelets ≥20,000/μL . With a median follow-up of one year, the 3 year overall and progression-free survivals are 60% and 50%, respectively. Figure Figure 90-Y Zevalin Dosing by Cohort (median; range) Cohort (cGy) Total Dose (mCi) mCi/kg 100 (n=3) 5 (2–14) .06(.05–.12) 300 (n=7) 22(14–57) .25(.18–.63) 500 (n=6) 31(16–48) .40(.14–.63) 700 (n=6) 37(26–55) .38(.27–.73) 900 (n=3) 28(27–37) .32(.27–.44) 1100 (n=3) 48(29–65) .57(.50–.75) The liver was the critical organ in nearly all cases. Patient-specific doses calculated to deliver a cohort-prescribed absorbed radiation dose to the critical organ were highly variable suggesting that dosing based on weight and not dosimetry is likely to result in a wide range of absorbed dose to critical organs. In the context of this study, 90YZ has been administered to eight patients at doses of .5 mCi/kg or greater. We conclude that with careful dosimetry, 90YZ doses higher than the conventional .4 mCi/kg may be safely combined with BEAM and autotransplant. Accrual continues at the 1300 cGy dose level.
90Y Ibritumomab Tiuxetan (Zevalin®; 90YZ) Doses Calculated To Deliver up to 1500 cGy to Critical Organs May Be Safely Combined with High-Dose BEAM and Autotransplant in NHL.
Inwards, David J. , Spies, Stewart, Wiseman, Gregory A., Erwin, William D. , Rademaker, Alfred , Williams, Stephanie , Tallman, Martin S. , Micallef, Ivana N. , Mehta, Jayesh, Zimmer, Michael, Molina, Arturo , Winter, Jane N. , Patton, David R. , Singhal, Seema , Evens, Andrew M. , Zimmer, Michael, White, Christine, Gordon, Leo I.

Blood | October 11, 2019 | Volume: 108 | Issue: 11 | Pages: 330-330

10.1182/blood.v108.11.330.330 Get It

Abstract 44 patients with relapsed or refractory CD20+ NHL were enrolled on a phase I trial of dose-escalated 90YZ followed by high-dose BEAM and autotransplant in which the 90YZ dose was patient-specific based on dosimetry. 90YZ doses were calculated to deliver cohort-defined radiation doses (100–1700 cGy) to critical organs (liver, lung or kidney) with 3–6 patients per cohort. On D-22, rituximab (R) 250 mg/m2 was infused followed by 111In Zevalin®. Imaging was performed immediately and at 4, 24, 72 and 144 hours; dosimetry was performed on D-15. On D-14, R was followed immediately by 90YZ at the cohort-prescribed dose. On D-6 through D-1, patients received high-dose BEAM. On D0, a minimum of 2.0 × 106 CD 34+ cells/kg was infused and G-CSF 5 μg/kg SQ daily begun. The median age was 54 (range: 25–73) years. NHL histologic subtypes were as follows: 16% mantle cell, 57% diffuse aggressive, 11% low-grade and 16% transformed. 43% had recieved 3 or more chemotherapy regimens, and 70% had received R either alone or in combination with chemotherapy. The toxicity profile was similar to that associated with high-dose BEAM. The most common grade III/IV toxicities were infection, fever, stomatitis, nausea, vomiting, diarrhea. One patient experienced transient veno-occlusive disease at the 700 cGy dose level. Two dose-limiting toxicities occurred at the 1700 cGy dose level: one patient with grade 4 stomatitis died of pneumonia and sepsis on D+10, and one patient experienced septic emboli to the lung on D+13. Engraftment occurred at a median of 10 days (range: 8–18 ) to granulocytes ≥ 500/μL, and 21 days (range: 11–40 days) to platelets ≥20,000/μL. One heavily pretreated patient developed MDS on D+291 and expired of sepsis on D+483. With a median follow-up of 21 months, the three year overall and progression-free survivals are 52% and 37%, respectively. 90YZ Zevalin ® Dosing for Cohorts 5–9 (median;range) Cohort (cGy) Total Dose (mCi) mCi/kg 900(n=3) 28(27–37) 0.3(0.3–0.4) 1100(n=5) 51(29–65) 0.6(0.5–0.8) 1300(n=5) 61(39–98) 0.6(0.5–1.1) 1500(n=6) 73(51–99) 0.9(0.5–1.4) 1700(n=3) 98(82–104) 1.2(1.1–1.2) For dosimetry-based trials, 1500 cGy to the critical organ (nearly always liver) is the recommended dose. Although patient-specific doses calculated to deliver a cohort-prescribed absorbed radiation dose to the critical organ were highly variable, the two dose-limiting toxicities ocurred at nearly identical doses (1.14, 1.20 mCi/kg) when calculated according to weight. Whereas eight other patients safely received at least twice the conventional 0.4 mCi/kg dose, 0.8 mCi/kg is the recommended dose for phase II studies, if dosing is to be based on weight and not dosimetry. Outcomes are encouraging given the high-risk patient population. A phase III trial will be required to establish whether or not the addition of 90YZ to high-dose BEAM improves outcomes in NHL patients undergoing autotransplant.
Yttrium-90 Ibritumomab Tiuxetan Doses Calculated to Deliver up to 15 Gy to Critical Organs May Be Safely Combined With High-Dose BEAM and Autologous Transplantation in Relapsed or Refractory B-Cell Non-Hodgkin's Lymphoma
Inwards, David J. , Spies, Stewart, Wiseman, Gregory A., Patton, David R. , Erwin, William D. , Rademaker, Alfred , Weitner, Bing Bing, Williams, Stephanie , Tallman, Martin S. , Micallef, Ivana N. , Mehta, Jayesh, Evens, Andrew M. , Zimmer, Michael, Molina, Arturo , Gordon, Leo I. , Winter, Jane N. , Singhal, Seema , White, Christine A. , Gordon, Leo I , Evens, Andrew M , Patton, David R

Journal of Clinical Oncology | March 3, 2009 | Volume: 27 | Issue: 10 | Pages: 1653-1659

10.1200/jco.2008.19.2245 Get It

Purpose To determine the maximum-tolerated radiation-absorbed dose (RAD) to critical organs delivered by yttrium-90 (90Y) ibritumomab tiuxetan in combination with high-dose carmustine, etoposide, cytarabine, and melphalan (BEAM) chemotherapy with autologous transplantation. Patients and Methods Eligible patients had relapsed or refractory CD20+ non-Hodgkin's lymphoma (NHL). Individualized 90Y activities were based on dosimetry and were calculated to deliver cohort-defined RAD (1 to 17 Gy) to critical organs with three to six patients per cohort. The therapeutic dose of 90Y ibritumomab tiuxetan was followed by high-dose BEAM and autologous transplantation. Results Forty-four patients were treated. Thirty percent of patients had achieved less than a partial remission to their most recent therapy and would not have been eligible for autologous transplantation at most centers. The toxicity profile was similar to that associated with high-dose BEAM chemotherapy. Two dose-limiting toxicities occurred at the 17 Gy dose level, which made 15 Gy the recommended maximum-tolerated RAD. Although eight patients received at least twice the conventional dose of 0.4 mCi/kg, a weight-based strategy at 0.8 mCi/kg would have resulted in a wide range of RAD; nearly 25% of patient cases would have received 17 Gy or more, and many would have received less than 10 Gy. With a median follow-up of 33 months for all patients, the estimated 3-year progression-free and overall survivals were 43% and 60%, respectively. Conclusion Dose-escalated 90Y ibritumomab tiuxetan may be safely combined with high-dose BEAM with autologous transplantation and has the potential to be more effective than standard-dose radioimmunotherapy. Careful dosimetry is required to avoid toxicity and undertreatment.
Radiation Dosimetry Results From a Phase II Trial of Ibritumomab Tiuxetan (Zevalin™) Radioimmunotherapy for Patients With Non-Hodgkin's Lymphoma and Mild Thrombocytopenia
Wiseman, Gregory A., Leigh, Bryan R., Erwin, William D. , Sparks, Richard, Podoloff, Donald A., Schilder, Russell J., Spies, Stewart, Grillo-López, Antonio J, White, Christine A., Bartlett, Nancy L. , Witzig, Thomas E.

Cancer Biotherapy and Radiopharmaceuticals | May 21, 2003 | Volume: 18 | Issue: 2 | Pages: 165-178

10.1089/108497803765036337 Get It