Back to Authors

Arafa, Amr

https://orcid.org/0009-0008-5135-5166

Mayo Clinic

Alexandria University

Citations 3

Abstract 4367116: Renal Artery Denervation in Patients with Resistant Hypertension: A systematic review and meta-Analysis
Kholeif, Zeyad , Rashwan, Rana , Elnady, Mohamed , Elnashar, Mohab , Nassar, Mostafa, El-Sharkawy, Ahmed A., Ali, Ahmed, Barsoom, Ramez , Elalfy, Aya, Gadelmawla, Ahmed Farid , Arafa, Amr , Gadelmawla, Ahmed Farid , Tahhan, Imad Samman , Mohamed, Ahmed A. , Elsharkawy, Ahmed, Alomari, Amal, Abdou, Khaled, Hemida, Mohamed Fawzi , Ali, Ahmed

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4367116 Get It

Background: Resistant hypertension (RH), defined as uncontrolled blood pressure (BP) despite ≥3 antihypertensive agents at maximally tolerated doses, remains a significant therapeutic challenge. Device-based renal denervation (RDN), using either radiofrequency (RF) or ultrasound (US) ablation, has shown promise in reducing BP. While both methods have demonstrated efficacy versus sham controls in randomized controlled trials (RCTs), direct comparisons remain limited. We conducted a systematic review and meta-analysis to evaluate the efficacy and safety of RF- and US-based RDN in patients with resistant hypertension. Methods: Following PRISMA guidelines, we searched PubMed, Scopus, and Web of Science through April 2025 for RCTs comparing RDN versus sham in RH. Eligible trials reported systolic or diastolic BP outcomes via ambulatory, office, or home measurements. Pooled mean differences (MD) and risk ratios (RR) were calculated using a random-effects model. Subgroup analyses were conducted by RDN modality and follow-up duration. Results: Seventeen RCTs met inclusion criteria. RDN significantly reduced ambulatory systolic BP (MD: −3.14 mmHg; 95% CI: −5.30 to −0.98; p=0.004) and diastolic BP (MD: −1.40 mmHg; 95% CI: −2.45 to −0.35; p=0.009) compared to sham. RF-based RDN showed consistent statistically significant reductions in both SBP and DBP across ambulatory and in-office measurements. In contrast, US-based RDN demonstrated variable efficacy, with only daytime DBP showing a marginal benefit (MD: −1.32 mmHg; p=0.04). Safety outcomes, including mortality, acute kidney injury, hypertensive crisis, and hypotension, were similar between groups. Conclusion: RDN offers a significant BP-lowering effect in resistant hypertension, with RF-based RDN yielding more consistent benefits across diverse measurement settings. US-based RDN showed limited but promising effects. Both techniques demonstrated acceptable safety profiles. Further head-to-head trials are needed to confirm long-term comparative effectiveness.
Abstract 4144289: Left atrial appendage isolation in catheter ablation of atrial fibrillation: An updated systematic review and meta-analysis.
Mohamed, Ahmed , Elesawy, Mahmoud , Afify, Raneem, Ramadan, Shrouk , Desouki, Mariam, Elnady, Mohamed , Shams, Mahmoud M. , Elkhayat, Ibrahim , Elbenawi, Hossam , Arafa, Amr Ossama Gaber, Arafa, Amr , Abdelaziz, Ahmed

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4144289 Get It

Introduction: Atrial fibrillation is the most encountered arrhythmia in clinical settings, with an estimate of 6 million cases in the United States. A growing amount of evidence has been supporting the role of left atrial appendage in left sided atrial fibrillation with conflict results. We aim in this study to provide a more in-depth guide for optimal left sided atrial fibrillation ablation strategy. Methods: We searched PubMed, Web of Science, Cochrane and Scopus for published studies until May 2024. We included relevant studies that compared the left atrial appendage electrical isolation versus the standard ablation and reported our outcomes of interest. The main outcomes of the study were the recurrence of atrial arrhythmia and the incidence of stroke or transient ischemic attack during the follow-up period. Data were pooled as Mean difference (MD) or risk ratio (RR) with their 95% CI using a fixed-effect model. Results: Eleven studies with 3040 patients were included in the final analysis. Left atrial appendage electrical isolation was associated with a significant reduction in atrial arrhythmia recurrence compared to the standard ablation alone (OR: 0.41, 95% CI: 0.35 to 0.48). However, it was also associated with a significant increase in stroke or transient ischemic attack incidence (OR: 1.48, 95% CI: 1.09 to 3.12). Conclusion: Left atrial appendage electrical isolation led to a significantly lower atrial arrhythmia recurrence, but this was achieved with an increased risk of stroke and transient ischemic attack incidence during the follow-up period.
Abstract 4144270: Air purification with portable air cleaners and its effect on blood pressure : An updated systematic review and meta-analysis of 21 studies.
Mohamed, Ahmed , Elbenawi, Hossam , Afify, Raneem, Desouki, Mariam, Elkhayat, Ibrahim , Arafa, Amr Ossama Gaber, Elnady, Mohamed , Shams, Mahmoud M. , Elesawy, Mahmoud, Abdelaziz, Ahmed , Arafa, Amr , Ramadan, Shrouk

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4144270 Get It

Background: Air pollution is a leading cause of cardiovascular diseases including ischemic heart disease and stroke contributing to millions of deaths, with elevated blood pressure, endothelial dysfunction, and systemic inflammation being some of the most important underlying mechanisms. Various studies showed a promising beneficial effect of indoor air purification on various health outcomes, including blood pressure. We aimed to assess the effect of indoor air purification on systolic blood pressure (SBP) and Diastolic blood pressure (DBP) and provide a rationale for home use of these filters. Methods: We searched PubMed, Web of Science, Cochrane and Scopus for published literature up to May 2024. We included studies that assessed air purification, including HEPA filters or electrostatic air filters, as an intervention compared to no intervention. The primary outcome of interest was mean changes in blood pressure both systolic and diastolic. Secondary outcomes were biomarkers of inflammation and oxidative stress. Mean difference (MD) and 95% CI was used in a fixed-effect model to analyze the data. Results: A total of 21 studies were included in our meta-analysis with a total of 1955 participants. Air purification was associated with a significant reduction in systolic blood pressure (SBP) (MD: -2.42, 95% CI: -3.42, -1.41), and diastolic blood pressure (DBP) (MD: -1.11, 95% CI: -1.76, -0.46). However, there was no significant changes in levels of inflammatory biomarkers or oxidative stress. Conclusion: Indoor air purification was associated with significant reductions in systolic and diastolic blood pressure levels, but questions arise whether these reductions are clinically relevant or not. Further studies should assess these findings. Conclusion: Indoor air purification was associated with significant reductions in systolic and diastolic blood pressure levels, but questions arise whether these reductions are clinically relevant or not. Further studies should assess these findings.