Liquid Chromatographic–Tandem Mass Spectrometric Method for the Determination of 5-Hydroxyindole-3-acetic Acid in Urine
Kroll, Charles, Magera, Mark J , Helgeson, Janice K, Matern, Dietrich , Rinaldo, Piero

Clinical Chemistry | January 24, 2020 | Volume: 48 | Issue: 11 | Pages: 2049-2051

10.1093/clinchem/48.11.2049 Get It

Rapid Determination of Transferrin Isoforms by Immunoaffinity Liquid Chromatography and Electrospray Mass Spectrometry
Lacey, Jean M., Bergen, H. Robert, Magera, Mark J , Naylor, Stephen , O’Brien, John F.

Clinical Chemistry | January 23, 2020 | Volume: 47 | Issue: 3 | Pages: 513-518

10.1093/clinchem/47.3.513 Get It

AbstractBackground: Congenital disorders of glycosylation (CDG) are autosomal recessive disorders that produce increased serum carbohydrate-deficient transferrin (CDT) isoforms. Methods to resolve CDT from fully glycosylated transferrin (Trf) have been based on a neutral shift in the isoelectric focusing (IEF) pattern or on a reduction in the negative charge, allowing resolution by anion-exchange chromatography. Our purpose was to develop a method of resolution and relative quantification of Trf isoforms using online immunoaffinity liquid chromatography–mass spectrometry (LC-MS).Methods: Serum (25 μL) was diluted with 100 μL of water before application to an immunoaffinity column that sequestered Trf isoforms. Trf isoforms were eluted from the immunoaffinity column, concentrated on a C4 column, eluted from the C4 column, and introduced into the mass spectrometer. Analysis of the Trf isoforms was entirely automated and completed in <10 min per sample.Results: The LC-MS method demonstrated that the major abnormal Trf isoforms in CDG lack one complete oligosaccharide structure (mono-oligosaccharide) or both oligosaccharide structures (a-oligosaccharide), but not the sialic acids, as presumed on the basis of IEF methods. Calculation of relative ratios among three possible species (mono-/di-oligosaccharide and a-/di-oligosaccharide) is reproducible [mean intra- and interassay CVs were 9.3% (n = 10) and 10% (n = 5), respectively]. A reference range for patients <18 years was determined by analysis of 209 samples (for mono-/di-oligosaccharide, the median was 0.041 and the range was 0.018–0.083; for a-/di-oligosaccharide, the median was 0.007 and the range was 0.002–0.036). Comparison of data obtained with an affinity chromatography-IEF method and the LC-MS method demonstrated equivalence in the interpreted results (n = 170).Conclusions: Advantages of the LC-MS method include improved sensitivity, minimal sample preparation, and an analysis time of <10 min. The method was automated, which allowed high throughput, with >100 samples analyzed in a single day. Moreover, the nature of the oligosaccharide defect in CDG is accurately reflected by mass resolution, and subtle oligosaccharide truncations may also be detected by this method.
Methylmalonic Acid Measured in Plasma and Urine by Stable-Isotope Dilution and Electrospray Tandem Mass Spectrometry
Magera, Mark J , Helgeson, Janice K, Matern, Dietrich , Rinaldo, Piero

Clinical Chemistry | January 23, 2020 | Volume: 46 | Issue: 11 | Pages: 1804-1810

10.1093/clinchem/46.11.1804 Get It

Abstract Background: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization is robust and allows accurate measurement of both low- and high-molecular weight components of complex mixtures. We developed a LC-MS/MS method for the analysis of methylmalonic acid (MMA), a biochemical marker for inherited disorders of propionate metabolism and acquired vitamin B12 deficiency. Methods: We added 1 nmol of the internal standard MMA-d3 to 500 μL of plasma or 100 μL of urine before solid-phase extraction. After elution with 18 mol/L formic acid, the eluate was evaporated, and butyl ester derivatives were prepared with 3 mol/L HCl in n-butanol at 65 °C for 15 min. For separation, we used a Supelcosil LC-18, 33 × 4.6 mm column with 60:40 (by volume) acetonitrile:aqueous formic acid (1 g/L) as mobile phase. The transitions m/z 231 to m/z 119 and m/z 234 to m/z 122 were used in the selected reaction monitoring mode for MMA and MMA-d3, respectively. The retention time of MMA was 2.2 min in a 3.0-min analysis, without interference of a physiologically more abundant isomer, succinic acid. Results: Daily calibrations between 0.25 and 8.33 nmol in 0.5 mL exhibited consistent linearity and reproducibility. At a plasma concentration of 0.12 μmol/L, the signal-to-noise ratio for MMA was 40:1. The regression equation for our previous gas chromatography-mass spectrometry (GC-MS) method (y) and the LC-MS/MS method (x) was: y = 1.030x − 0.032 (Sy|x = 1.03 μmol/L; n = 106; r = 0.994). Inter- and intraassay CVs were 3.8–8.5% and 1.3–3.4%, respectively, at mean concentrations of 0.13, 0.25, 0.60, and 2.02 μmol/L. Mean recoveries of MMA added to plasma were 96.9% (0.25 μmol/L), 96.0% (0.60 μmol/L), and 94.8% (2.02 μmol/L). One MS/MS system used only overnight (7.5 h) replaced two GC-MS systems (30 instrument-hours/day) to run 100–150 samples per day, with reductions of total cost (supplies plus equipment), personnel, and instrument time of 59%, 14%, and 75%, respectively. Conclusions: This method is well suited for large-scale MMA testing (≥100 samples per day) where a shorter analytical time is highly desirable. Reagents are less expensive than the anion-exchange/cyclohexanol-HCl method, and sample preparation of batches up to 100 specimens is completed in less than 8 h and is automated.
Quantitative Measurement of Porphobilinogen in Urine by Stable-Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
Ford, Roddey E., Magera, Mark J , Kloke, Karen M., Chezick, Paul A., Fauq, Abdul H. , McConnell, Joseph P.

Clinical Chemistry | January 23, 2020 | Volume: 47 | Issue: 9 | Pages: 1627-1632

10.1093/clinchem/47.9.1627 Get It

AbstractBackground: Measurement of porphobilinogen (PBG) is useful in the diagnosis of the acute neurologic porphyrias. Currently used colorimetric assays lack analytical and clinical sensitivity and specificity.Methods: We developed a liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the measurement of PBG in 1 mL of urine, using 5-(aminoethyl)-4-(carboxymethyl) 1H-2,4-[13C]pyrolle-3-propanoic acid ([2,4-13C]PBG; 2.75 μg) as internal standard. After solid-phase extraction, LC-MS/MS analysis was performed in the selected-reaction monitoring (SRM) mode. PBG and [2,4-13C]PBG were monitored through their own precursor and product ion settings (m/z 227 to 210 and m/z 229 to 212, respectively). The retention time of PBG and [2,4-13C]PBG was 1.0 min in a 2.3-min analysis.Results: Daily calibrations (n = 6) between 0.1 and 2.0 mg/L were linear and reproducible. Inter- and intraassay CVs were 3.2–3.5% and 2.6–3.1%, respectively, at mean concentrations of 0.24, 1.18, and 2.15 mg/L. The regression equation for the comparison between an anion-exchange column method (y) and the LC-MS/MS method (x) was: y = 0.84x + 0.74 (Sy|x = 5.8 mg/24 h; r = 0.85; n = 100). In 47 volunteers, PBG excretion was 0.02–0.42 mg/24 h, lower than reported reference intervals (up to 2.0 mg/24 h) based on colorimetric methods. In 85 samples with PBG ≤0.5 by LC-MS/MS, 8 (9.4%) had values ≥2.0 mg/24 h by the anion-exchange method (mean ± SD, 4.3 ± 1.8 mg/24 h). In 11 patients with confirmed diagnoses of acute porphyria and increased PBG by LC-MS/MS, 2 had values within the reported reference intervals by a quantitative anion-exchange method.Conclusions: The quantitative LC-MS/MS method for PBG measurement exhibits greater analytical specificity and improved clinical sensitivity and specificity than currently available methods.
Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry
Magera, Mark J , Lacey, Jean M., Casetta, Bruno, Rinaldo, Piero

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 9 | Pages: 1517-1522

10.1093/clinchem/45.9.1517 Get It

Abstract Background: Total homocysteine (tHcy) has emerged as an important independent risk factor for cardiovascular disease. Analytical methods are needed to accommodate the high testing volumes for tHcy and provide rapid turnaround. Methods: We developed liquid chromatography electrospray tandem mass spectrometry (LC-MS/MS) method based on the analysis of 100 μL of either plasma or urine with homocystine-d8 (2 nmol) added as internal standard. After sample reduction and deproteinization, the analysis was performed in the multiple reaction monitoring mode in which tHcy and Hcy-d4 were detected through the transition from the precursor to the product ion (m/z 136 to m/z 90 and m/z 140 to m/z 94, respectively). The retention time of tHcy and Hcy-d4 was 1.5 min in a 2.5-min analysis. Results: Daily calibrations between 2.5 and 60 μmol/L exhibited consistent linearity and reproducibility. At a plasma concentration of 0.8 μmol/L, the signal-to-noise ratio for tHcy was 17:1. The regression equation for the comparison between our previous HPLC method (y) and the LC-MS/MS method (x) was y = 1.097x − 1.377 (r = 0.975; Sy|x =1.595 μmol/L; n = 367), and for comparison between a fluorescence polarization immunoassay (Abbott IMx; y) and LC-MS/MS (x) was y = 1.039x + 0.025 (r = 0.969; Sy|x =1.146 μmol/L; n = 367). Inter- and intraassay CVs were 2.9–5.9% and 3.6–5.3%, respectively, at mean concentrations of 3.9, 22.7, and 52.8 μmol/L. Mean recovery of tHcy was 94.2% (20 μmol/L) and 97.8% (50 μmol/L). Conclusions: The sensitivity and specificity of tandem mass spectrometry are well suited to perform high-volume analysis of tHcy. Reagents are inexpensive and sample preparation of a batch of 40 specimens is completed in less than 1 h and is amenable to automation.
Measurement of psychosine in dried blood spots — a possible improvement to newborn screening programs for Krabbe disease
Turgeon, Coleman , Orsini, Joseph J. , Sanders, Karen A., Magera, Mark J , Langan, Thomas J. , Escolar, Maria L. , Duffner, Patricia K., Oglesbee, Devin , Gavrilov, Dimitar , Tortorelli, Silvia , Rinaldo, Piero, Raymond, Kimiyo , Matern, Dietrich , Turgeon, Coleman T, Oglesbee, Devin

Journal of Inherited Metabolic Disease | March 11, 2015 | Volume: 38 | Issue: 5 | Pages: 923-929

10.1007/s10545-015-9822-z Get It

AbstractBackgroundNewborn screening (NBS) for Krabbe disease (KD) in New York and Missouri is conducted by measuring galactocerebrosidase (GALC) activity using tandem mass spectrometry (MS/MS). These NBS efforts have shown that the incidence of KD is unexpectedly low (1:400,000) while many individuals (ca. 1:6000) with reduced GALC activity and genotypes of uncertain significance are detected and subjected to follow up testing. Psychosine (PSY) is a putative marker of KD progression and can be measured in dried blood spots (DBS). We sought to determine the role that PSY levels play in NBS for KD, follow up, and treatment monitoring.MethodsPSY was eluted from DBS with methanol containing N,N‐dimethyl‐D‐erythro‐sphingosine as internal standard (IS). Liquid chromatography‐MS/MS was conducted over 17 minutes in the multiple reaction monitoring positive mode to follow the precursor to product species transitions for PSY and IS. Separation of the structural isomers PSY and glucosylsphingosine was accomplished by hydrophilic interaction liquid chromatography.ResultsPre‐analytical and analytical factors were studied and revealed satisfactory results. PSY was also measured in DBS collected from controls (range: <8 nmol/L, N = 220), KD patients at various disease stages (range: 8–112, N = 26), and GALC mutation carriers (range: <15 nmol/L, N = 18).ConclusionsPSY measurement in DBS could serve as a 2nd tier assay in NBS for KD, simplify and reduce the cost of follow up protocols, help determine disease progression, and be used to monitor KD patients following hematopoietic stem cell transplantation. However, additional chronological measurements of PSY in KD patients are required to confirm these possibilities.
Determination of Total Homocysteine, Methylmalonic Acid, and 2-Methylcitric Acid in Dried Blood Spots by Tandem Mass Spectrometry
Turgeon, Coleman , Magera, Mark J , Cuthbert, Carla, Loken, Perry R , Gavrilov, Dimitar K. , Tortorelli, Silvia , Raymond, Kimiyo , Oglesbee, Devin , Rinaldo, Piero, Matern, Dietrich , Gavrilov, Dimitar , Oglesbee, Devin

Clinical Chemistry | September 1, 2010 | Volume: 56 | Issue: 11 | Pages: 1686-1695

10.1373/clinchem.2010.148957 Get It

BACKGROUNDNewborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography–tandem mass spectrometry (LC-MS/MS).METHODSThe analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d3-MMA, d3-MCA, d8-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening.RESULTSThe 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 μmol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants.CONCLUSIONSApplication of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations.
Combined Newborn Screening for Succinylacetone, Amino Acids, and Acylcarnitines in Dried Blood Spots
Turgeon, Coleman , Magera, Mark J , Tortorelli, Silvia , Gavrilov, Dimitar , Oglesbee, Devin , Raymond, Kimiyo , Rinaldo, Piero, Matern, Dietrich , Allard, Pierre , Oglesbee, Devin

Clinical Chemistry | February 15, 2008 | Volume: 54 | Issue: 4 | Pages: 657-664

10.1373/clinchem.2007.101949 Get It

Abstract Background: Tyrosinemia type I (TYR 1) is a disorder causing early death if left untreated. Newborn screening (NBS) for this condition is problematic because determination of the diagnostic marker, succinylacetone (SUAC), requires a separate first-tier or only partially effective second-tier analysis based on tyrosine concentration. To overcome these problems, we developed a new assay that simultaneously determines acylcarnitines (AC), amino acids (AA), and SUAC in dried blood spots (DBS) by flow injection tandem mass spectrometry (MS/MS). Methods: We extracted 3/16-inch DBS punches with 300 μL methanol containing AA and AC stable isotope-labeled internal standards. This extract was derivatized with butanol-HCl. In parallel, we extracted SUAC from the residual filter paper with 100 μL of a 15 mmol/L hydrazine solution containing the internal standard 13C5-SUAC. We combined the derivatized aliquots in acetonitrile for MS/MS analysis of AC and AA with additional SRM experiments for SUAC (m/z 155–137) and 13C5-SUAC (m/z 160–142). Analysis time was 1.2 min. Results: SUAC was increased in retrospectively analyzed NBS samples of 11 TYR 1 patients (length of storage, 52 months to 1 week; SUAC range, 13–81 μmol/L), with Tyr concentrations ranging from 65 to 293 μmol/L in the original NBS analysis. The mean concentration of SUAC in 13 521 control DBS was 1.25 μmol/L. Conclusion: The inclusion of SUAC analysis into routine analysis of AC and AA allows for rapid and cost-effective screening for TYR 1 with no tangible risk of false-negative results.
Second-Tier Test for Quantification of Alloisoleucine and Branched-Chain Amino Acids in Dried Blood Spots to Improve Newborn Screening for Maple Syrup Urine Disease (MSUD)
Oglesbee, Devin , Sanders, Karen A., Lacey, Jean M., Magera, Mark J , Casetta, Bruno , Strauss, Kevin A. , Tortorelli, Silvia , Rinaldo, Piero, Matern, Dietrich , Oglesbee, Devin

Clinical Chemistry | January 5, 2008 | Volume: 54 | Issue: 3 | Pages: 542-549

10.1373/clinchem.2007.098434 Get It

AbstractBackground: Newborn screening for maple syrup urine disease (MSUD) relies on finding increased concentrations of the branched-chain amino acids (BCAAs) leucine, isoleucine, and valine by tandem mass spectrometry (MS/MS). d-Alloisoleucine (allo-Ile) is the only pathognomonic marker of MSUD, but it cannot be identified by existing screening methods because it is not differentiated from isobaric amino acids. Furthermore, newborns receiving total parenteral nutrition often have increased concentrations of BCAAs. To improve the specificity of newborn screening for MSUD and to reduce the number of diet-related false-positive results, we developed a LC-MS/MS method for quantifying allo-Ile.Methods: Allo-Ile and other BCAAs were extracted from a 3/16-inch dried blood spot punch with methanol/H2O, dried under nitrogen, and reconstituted into mobile phase. Quantitative LC-MS/MS analysis of allo-Ile, its isomers, and isotopically labeled internal standards was achieved within 15 min. To determine a reference interval for BCAAs including allo-Ile, we analyzed 541 dried blood spots. We also measured allo-Ile in blinded samples from 16 MSUD patients and 21 controls and compared results to an HPLC method.Results: Intra- and interassay imprecision (mean CVs) for allo-Ile, leucine, isoleucine, and valine ranged from 1.8% to 7.4%, and recovery ranged from 91% to 129%. All 16 MSUD patients were correctly identified.Conclusions: The LC-MS/MS method can reliably measure allo-Ile in dried blood spots for the diagnosis of MSUD. Applied to newborn screening as a second-tier test, it will reduce false-positive results, which produce family anxiety and increase follow-up costs. The assay also appears suitable for use in monitoring treatment of MSUD patients.
Automated Spectrophotometric Analysis of Mitochondrial Respiratory Chain Complex Enzyme Activities in Cultured Skin Fibroblasts
Kramer, Karen A., Oglesbee, Devin , Hartman, Stacy, Huey, Joe, Anderson, Bambi D., Magera, Mark J , Matern, Dietrich , Rinaldo, Piero, Robinson, Brian H., Cameron, Jessie M. , Hahn, Si Houn , Oglesbee, Devin

Clinical Chemistry | September 3, 2005 | Volume: 51 | Issue: 11 | Pages: 2110-2116

10.1373/clinchem.2005.050146 Get It

Abstract Background: Mitochondrial respiratory chain complex (RCC) disorders may occur as commonly as 1 in 8500 individuals. Because of the great variability of phenotypic presentations, measurement of individual RCC enzyme activities is a crucial diagnostic process. Current assay methods are time-consuming and labor-intensive and thus constitute a major impediment to clinical practice. A method with a faster turnaround time would therefore be beneficial. Method: We developed an automated spectrophotometric method for measuring the respiratory chain enzyme activities of complex I, complex II + III, and complex IV with the Hitachi 912, an automated spectrophotometer. Mitochondrial citrate synthase was also determined for normalization of the RCC activities. Results: A blinded method comparison with samples from an external testing center yielded a 91% concordance of interpretations. Mean intraassay imprecision (as CV; n = 20) in a single batch analysis of each RCC was 5.9%. Interassay imprecision, evaluated on 2 samples harvested and analyzed 3 times each, gave mean CVs of 10%–18%. Conclusions: With this automated method, a panel of RCC enzyme activities can be determined in &lt;2 h. In addition, an immunoblot assay using monoclonal antibodies against specific subunits of RCC enzyme complexes can be informative in cases of borderline enzyme activity. Our results suggest that in vitro diagnosis of RCC enzyme deficiencies in skin fibroblasts is an effective alternative to invasive muscle biopsy.