Back to Authors

Gandhi, Manish J.

https://orcid.org/0000-0001-7210-1909

Mayo Clinic

Mayo Clinic

Citations 60

Comparison of two double red cell collection settings on Fenwal Alyx apheresis instrument
Burgstaler, Edwin A. , Duffy, Kimberly J., Gandhi, Manish J.

Journal of Clinical Apheresis | February 9, 2017 | Volume: 32 | Issue: 6 | Pages: 392-396

10.1002/jca.21527 Get It

AbstractThe Fenwal Alyx for collecting double red cell products has two red cell volume collection settings: fixed collection target of 360 ml (180 ml/unit) and a variable target of collecting either 400 or 360 ml (200 or 180 ml/unit), where the machine aims for the higher possible collection target. We retrospectively compared the two collection targets for the RBC content, donor time, technician time, and collection efficiency. We compared 18 fixed (F) target collections to 40 variable (V) target collections. All collections were performed as per the manufacturer's recommendations on Alyx and donors met the manufacturer's eligibility criteria. There was no significant difference in average whole blood processed (F: 963 ml, V: 1,000 ml); donor time (F: 43 min, V: 45 min) or technician time (F: 64 min, V: 64 min). There was a significant difference in unit volume (F: 283 ml, V: 300 ml); grams Hb/unit (F: 53 g, V: 57 g); ml RBC/unit (F: 157 ml, V: 167 ml); and RBC recovery (F: 87.8%, V: 88.9%). The fixed target had a significantly lower frequency of products with ≥51 g Hb (80.6%) than variable target (96.3%) and ≥153 ml RBC/unit (F: 55.6%, V: 96.3%). In conclusion, the variable target efficiently allows collections of products with higher red cell volume and hemoglobin without a significant increase in collection and processing time.
72: Exploring Associations Between Genotype and Serology in Celiac Disease
Mills, John R. , Katzman, Brooke M. , Ettore, Michael, Snyder, Melissa R., Murray, Joseph A. , Gandhi, Manish J. , Snyder, Melissa R.

American Journal of Clinical Pathology | February 3, 2017 | Volume: 143 | Issue: suppl_1 | Pages: A042-A042

10.1093/ajcp/143.suppl1.043 Get It

16th IHIW: Global distribution of extended HLA haplotypes
Askar, Medhat , Daghstani, J., Thomas, Dawn, Leahy, N., Dunn, P.P.J. , Doran, Stephen , Saji, H., Kanangat, Siva, Karoichane, M., Tambur, Anat R. , Monos, Dimitri , El‐Khalifa, M. Y., Turner, Victoria , Kamoun, Malek , Mustafa, Mahiran, Ramón, Daniel S. , Vernaza, Alejandro, Gorodezky, Clara , Wagenknecht, Dawn R., Gautreaux, Michael D. , Hajeer, Ali H. , Fernández-Viña, Marcelo , Claas, Frans H.J. , Gandhi, Manish J. , Kashi, Zahra Mehdizadeh

International Journal of Immunogenetics | October 13, 2015 | Volume: 40 | Issue: 1 | Pages: 31-38

10.1111/iji.12029 Get It

SummaryThis report describes the project to identify the global distribution of extended HLA haplotypes, a component of 16th International HLA and Immunogenetics Workshop (IHIW), and summarizes the initial analyses of data collected. The project aims to investigate extended HLA haplotypes, compare their distribution among different populations, assess their frequency in hematopoietic stem cell unrelated donor registries and initiate an international family studies database and DNA repository to be made publicly available. HLA haplotypes compiled in immunogenetics laboratories during the evaluation of transplant candidates and related potential donors were analysed. Haplotypes were determined using the pedigree analysis tool publicly available from the National Marrow Donor Program (NMDP) website. Nineteen laboratories from 10 countries (11 laboratories from North America, five from Asia, two from Latin America and one from Australia) contributed data on a total of 1719 families comprised of 7474 individuals. We identified 10 393 HLA haplotypes, of which 1682 haplotypes included high‐resolution typing at HLA‐A, B, C, DRB1 and DQB1 loci. We also present haplotypes containing MICA and other HLA loci and haplotypes containing rare alleles seen in these families. The project will be extended through the 17th IHIW, and investigators interested in joining the project may communicate with the first author.
Recipient clinical risk factors predominate in possible transfusion‐related acute lung injury
Toy, Pearl, Bacchetti, Peter , Grimes, Barbara , Murphy, Edward L. , Gropper, Michael A. , Hubmayr, Rolf D., Matthay, Michael A. , Wilson, Gregory , Koenigsberg, Monique, Lee, Deanna C., Hirschler, Nora V., Lowell, Clifford A. , Schuller, Randy M. , Norris, Philip J. , Mair, David , Rosen, Rosa Sanchez, Looney, Mark R. , Winters, Jeffrey L. , Gajic, Ognjen , Gandhi, Manish J.

Transfusion | December 13, 2014 | Volume: 55 | Issue: 5 | Pages: 947-952

10.1111/trf.12954 Get It

Background Possible transfusion‐related acute lung injury (p TRALI ) cases by definition have a clear temporal relationship to an alternative recipient risk factor for acute respiratory distress syndrome ( ARDS ). We questioned whether transfusion factors are important for the development of p TRALI . Study Design and Methods In this nested case‐control study, we prospectively identified 145 consecutive patients with p TRALI and randomly selected 163 transfused controls over a 4‐year period at the U niversity of C alifornia at S an F rancisco and the M ayo C linic ( R ochester, M innesota). Results For p TRALI , we found evidence against transfusion being important: receipt of plasma from female donors (odds ratio [ OR ], 0.82; 95% confidence interval [ CI ], 0.29‐2.3; p = 0.70), total number of units transfused ( OR , 0.99; 95% CI , 0.89‐1.10; p = 0.86), and number of red blood cell and whole blood units transfused ( OR , 0.78; 95% CI , 0.59‐1.03; p = 0.079). In contrast, we found that risk for p TRALI was associated with additional recipient factors: chronic alcohol abuse ( OR , 12.5; 95% CI , 2.8‐55; p < 0.001), current smoker ( OR , 4.2; 95% CI , 1.67‐10.8; p = 0.0024), shock before transfusion ( OR , 4.6; 95% CI , 2.0‐10.7; p < 0.001), and positive fluid balance before transfusion ( OR , 1.32/ L ; 95% CI , 1.20‐1.44; p < 0.001). Conclusion Recipient risk factors for ARDS rather than transfusion risk factors predominate in p TRALI .
In Reply
Kreuter, Justin D. , Gandhi, Manish J.

Clinical Chemistry | January 9, 2014 | Volume: 60 | Issue: 2 | Pages: 424-424

10.1373/clinchem.2013.218115 Get It

Economic Rewards for Blood Donation: Validity of the Donor Questionnaire as Litmus Test
Kreuter, Justin D. , Gandhi, Manish J.

Clinical Chemistry | September 27, 2013 | Volume: 59 | Issue: 10 | Pages: 1538-1539

10.1373/clinchem.2013.211599 Get It

Amino acid substitution at peptide-binding pockets of HLA class I molecules increases risk of severe acute GVHD and mortality
Pidala, Joseph, Wang, Tao , Haagenson, Michael , Askar, Medhat , Baxter‐Lowe, Lee Ann , Bitan, Menachem, Fernández-Viña, Marcelo , Jakubowski, Ann A. , Maiers, Martin , Marino, Susana R. , Oudshoorn, Machteld, Palmer, Jeanne , Prasad, Vinod K. , Reddy, Vijay , Ringdén, Olle , Saber, Wael , Santarone, Stella , Schultz, Kirk R. , Setterholm, Michelle, Trachtenberg, Elizabeth, Turner, E. Victoria, Woolfrey, Ann E. , Lee, Stephanie J. , Anasetti, Claudio , Spellman, Stephen R. , Battiwalla, Minoo , Gandhi, Manish J. , Marsh, Steven G. E. , Ringden, Olov , Lee, Stephanie J , Maiers, Martin

Blood | August 28, 2013 | Volume: 122 | Issue: 22 | Pages: 3651-3658

10.1182/blood-2013-05-501510 Get It

Key PointsAmino acid substitution at peptide-binding residues of the HLA class I molecule is associated with graft-versus-host disease and mortality. Avoidance of donor-recipient combinations that result in amino acid substitution at peptide-binding residues may improve transplant outcomes.
Lot‐to‐lot variability in HLA antibody screening using a multiplexed bead‐based assay
Carrick, Danielle M. , Jenkins, Sarah M. , Goey, Steven R. De, Ploeger, Nancy A., Wilson, Gregory , Lee, Jar How, Winters, Jeffrey L. , Stubbs, James R. , Toy, Pearl, Norris, Philip J. , Gandhi, Manish J. , Winters, Jeffrey L

Transfusion | January 11, 2013 | Volume: 53 | Issue: 9 | Pages: 1940-1947

10.1111/trf.12064 Get It

BackgroundIdentifying antibodies to HLA (anti‐HLA) by solid‐phase assays is used to screen blood donors to mitigate transfusion‐related acute lung injury risk. Various cutoffs for detection assays have been proposed in the literature; however, these do not take into consideration lot‐to‐lot variability of commercially available assays.Study Design and MethodsSamples from 93 nontransfused males were tested using five different lots of a multiplex bead‐based anti‐HLA detection kit. A subset of 17 samples was tested on 5 days using a single lot. An additional 96 samples from donations with varied anti‐HLA levels were tested using kits from two different lots. Results were reported as a normalized background (NBG) ratio.ResultsFor the 93 nontransfused donors, NBG values generated using the reference lot were significantly higher than those obtained with three of the four comparator lots. However, for the 96 samples with low‐, moderate‐, and higher‐level anti‐HLA, Class I (CL‐I) values were 1.4 times lower and Class II (CL‐II) values were 1.2 times lower using the reference versus comparator lot. For CL‐I antibodies the between‐lot standard deviation (SD) was 1.36 (95% confidence interval [CI], 1.19‐1.60), while the between‐day SD was 1.27 (95% CI, 1.08‐1.52). Similarly, for CL‐II antibodies the between‐lot SD was 0.81 (95% CI, 0.70‐0.95), while the between‐day SD was 0.50 (95% CI, 0.43‐0.60).ConclusionsThere is interlot variability in the tested HLA detection assay as well as significant bias between lots. It may be reasonable to develop a new cutoff when a new lot is obtained.
Transfusion-related acute lung injury: incidence and risk factors
Toy, Pearl, Bacchetti, Peter , Looney, Mark R. , Gropper, Michael A. , Hubmayr, Rolf D., Lowell, Clifford A. , Norris, Philip J. , Murphy, Edward L. , Weiskopf, Richard B. , Wilson, Gregory , Koenigsberg, Monique, Lee, Deanna, Schuller, Randy M. , Wu, Ping , Grimes, Barbara , Winters, Jeffrey L. , Mair, David , Hirschler, Nora V., Rosen, Rosa Sanchez, Matthay, Michael A. , Group, for the TRALI Study, Gajic, Ognjen , Gandhi, Manish J. , Group, for the TRALI Study, Winters, Jeffrey L

Blood | November 24, 2011 | Volume: 119 | Issue: 7 | Pages: 1757-1767

10.1182/blood-2011-08-370932 Get It

AbstractTransfusion-related acute lung injury (TRALI) is the leading cause of transfusion-related mortality. To determine TRALI incidence by prospective, active surveillance and to identify risk factors by a case-control study, 2 academic medical centers enrolled 89 cases and 164 transfused controls. Recipient risk factors identified by multivariate analysis were higher IL-8 levels, liver surgery, chronic alcohol abuse, shock, higher peak airway pressure while being mechanically ventilated, current smoking, and positive fluid balance. Transfusion risk factors were receipt of plasma or whole blood from female donors (odds ratio = 4.5, 95% confidence interval [CI], 1.85-11.2, P = .001), volume of HLA class II antibody with normalized background ratio more than 27.5 (OR = 1.92/100 mL, 95% CI, 1.08-3.4, P = .03), and volume of anti–human neutrophil antigen positive by granulocyte immunofluoresence test (OR = 1.71/100 mL, 95% CI, 1.18-2.5, P = .004). Little or no risk was associated with older red blood cell units, noncognate or weak cognate class II antibody, or class I antibody. Reduced transfusion of plasma from female donors was concurrent with reduced TRALI incidence: 2.57 (95% CI, 1.72-3.86) in 2006 versus 0.81 (95% CI, 0.44-1.49) in 2009 per 10 000 transfused units (P = .002). The identified risk factors provide potential targets for reducing residual TRALI.