Abstract Objective: Determine if automated struts can successfully power a balanced cable transport (BCT) during tibial bone transport and thus benefit from the advantages of automation. Design: Retrospective observational case series. Setting: Level 1 trauma center. Patients/Participants: A retrospective analysis of 7 tibial BCTs using automated struts was performed with an average defect size of 102 mm. Outcomes: Union rate, complications, external fixation index, bone healing index, and mechanical alignment. Results: The average bone healing index was found to be 21.9 days/cm in bifocal BCT and 13.7 days/cm in trifocal BCT. Automated struts successfully powered 7 BCTs but were not without complications. Four patients had strut malfunctions necessitating unscheduled return to clinic. Other complications not secondary to the struts included pin tract infections (n = 4) and unplanned return to the operating room (n = 2, docking site nonunion and revision ankle arthrodesis). Conclusions: Automated struts powering BCT is feasible but not without complications. This treatment strategy combines the advantages of automation with the advantages of BCT. Incorporating automation into these complex constructs will allow for ease of use for patient and caregiver during the long process of bone transport, theoretically decrease noncompliance, which otherwise can cause severe complications, and increased segmentation, which may improve quality of regenerate bone formation. Level of Evidence: Level 4.
Regenerate stabilization with a photodynamic bone stabilization system after acute shortening and then lengthening: a case report
Abstract Case: A 42-year-old African-American woman sustained a type IIIA open pilon fracture requiring open reduction internal fixation complicated by wound dehiscence. Acute shortening for primary wound closure was performed followed by relengthening in a circular frame. Owing to the patient's intolerance to the circular frame, pre-existing osseous deformity, large body habitus, and soft tissue compromise, conversion to intramedullary stabilization with standard nailing was deemed exceedingly difficult. We describe the use of a photodynamic bone stabilization system allowing for percutaneous entry and implant flexibility for the purpose of early circular frame removal. Conclusion: This case demonstrates successful protection of immature regenerate using a photodynamic bone stabilization system, offering another tool to minimize time spent in a circular frame.