Back to Authors

Pagnano, Mark W.

https://orcid.org/0000-0003-1679-0046

Mayo Clinic

Mayo Clinic

Citations 56

Alignment in total knee arthroplasty
Oussedik, Sam, Victor, Jan , Pagnano, Mark W. , Haddad, Fares S. , Abdel, Matthew P.

The Bone & Joint Journal | February 29, 2020 | Volume: 102-B | Issue: 3 | Pages: 276-279

10.1302/0301-620x.102b3.bjj-2019-1729 Get It

Dissatisfaction following total knee arthroplasty is a well-documented phenomenon. Although many factors have been implicated, including modifiable and nonmodifiable patient factors, emphasis over the past decade has been on implant alignment and stability as both a cause of, and a solution to, this problem. Several alignment targets have evolved with a proliferation of techniques following the introduction of computer and robotic-assisted surgery. Mechanical alignment targets may achieve mechanically-sound alignment while ignoring the soft tissue envelope; kinematic alignment respects the soft tissue envelope while ignoring the mechanical environment. Functional alignment is proposed as a hybrid technique to allow mechanically-sound, soft tissue-friendly alignment targets to be identified and achieved.Cite this article: Bone Joint J 2020;102-B(3):276–279.
Intravenous Tranexamic Acid Safely and Effectively Reduces Transfusion Rates in Revision Total Knee Arthroplasties
Hines, Jeremy T. , Petis, Stephen M. , Amundson, Adam W. , Pagnano, Mark W. , Sierra, Rafael J. , Abdel, Matthew P. , Petis, Stephen , Abdel, Matthew P , Sierra, Rafael J

Journal of Bone and Joint Surgery | January 24, 2020 | Volume: 102 | Issue: 5 | Pages: 381-387

10.2106/jbjs.19.00857 Get It

Background: The efficacy and safety of tranexamic acid (TXA) in primary total knee arthroplasty (TKA) have been well established. However, there have been limited data for revision TKAs. The primary aim was to assess the impact of intravenous TXA on transfusion rates and symptomatic venous thromboembolic events (VTEs) in a large revision TKA cohort with or without intravenous TXA utilization. Methods: A retrospective review of revision TKAs performed from 2005 to 2014 was performed, identifying 2,951 procedures (2,219 patients), in which TXA was utilized in 1,144 procedures (39%). The mean age was 65 years with 52% female patients in the TXA revision group and 67 years with 52% female patients in the non-TXA revision group. Transfusion rates and symptomatic VTEs were the primary outcomes assessed. Comparisons were performed between cohorts, utilizing a unique propensity model to mitigate bias, on the basis of TXA use and subsequently for aseptic or septic revision etiology. Results: Significant reductions in transfusion rates with use of TXA were identified in revision TKAs overall (13% compared with 39%; p < 0.001 [adjusted relative risk, 1.7]), including revisions for both aseptic etiology (6% with TXA compared with 28% without TXA; p < 0.001) and septic etiology (31% with TXA compared with 54% without TXA; p < 0.001). The risk of a postoperative symptomatic VTE was not significantly different (adjusted p = 0.63) with use of TXA at 11 events (1.0%) compared with 24 events (1.3%) in the non-TXA group). Conclusions: Intravenous TXA significantly reduced transfusion rates in revision TKAs by approximately twofold, including cohorts revised for aseptic and septic etiologies. There was a very low rate of VTEs (1.2%) with no significant difference in the number of VTEs between groups after adjusting risk utilizing propensity modeling. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Continuous Posterior Lumbar Plexus Nerve Block Versus Periarticular Injection with Ropivacaine or Liposomal Bupivacaine for Total Hip Arthroplasty
Johnson, Rebecca L. , Amundson, Adam W. , Sviggum, Hans P. , Mabry, Tad M. , Mantilla, Carlos B. , Schroeder, Darrell R. , Pagnano, Mark W. , Kopp, Sandra L. , Mantilla, Carlos B , Kopp, Sandra , Johnson, Rebecca L , Schroeder, Darrell , Abdel, Matthew P.

Journal of Bone and Joint Surgery | November 14, 2019 | Volume: 99 | Issue: 21 | Pages: 1836-1845

10.2106/jbjs.16.01305 Get It

Background: Debate surrounds the issue of whether peripheral nerve blockade or periarticular infiltration (PAI) should be employed within a contemporary, comprehensive multimodal analgesia pathway for total hip arthroplasty. We hypothesized that patients treated with a continuous posterior lumbar plexus block (PNB) would report less pain and consume less opioid medication than those treated with PAI. Methods: This investigator-initiated, independently funded, 3-arm randomized clinical trial (RCT) performed at a single high-volume institution compared postoperative analgesia interventions for elective, unilateral primary total hip arthroplasty: (1) PNB; (2) PAI with ropivacaine, ketorolac, and epinephrine (PAI-R); and (3) PAI with liposomal bupivacaine, ketorolac, and epinephrine (PAI-L) using computerized randomization. The primary outcome was maximum pain during the morning (06:00 to 12:00) of the first postoperative day (POD) on an ascending numeric rating scale (NRS) from 0 to 10. Pairwise treatment comparisons were performed using the rank-sum test, with a p value of <0.017 indicating significance (Bonferroni adjusted). A sample size of 150 provided 80% power to detect a difference of 2.0 NRS units. Results: We included 159 patients (51, 54, and 54 patients in the PNB, PAI-R, and PAI-L groups, respectively). No significant differences were found with respect to the primary end point on the morning of the first POD (median, 3.0, 4.0, and 3.0, respectively; p > 0.033 for all). Opioid consumption was low and did not differ across groups at any intervals. Median maximum pain on POD 1 was 5.0, 5.5, and 4.0, respectively, and was lower for the PAI-L group than for the PAI-R group (p = 0.006). On POD 2, maximum pain (median, 3.5, 5.0, and 3.5, respectively) was lower for the PNB group (p = 0.014) and PAI-L group (p = 0.016) compared with the PAI-R group. The PAI-L group was not significantly different from the PNB group with respect to any outcomes: postoperative opioid use including rescue intravenous opioid medication, length of stay, and hospital adverse events, and 3-month follow-up data including any complication. Conclusions: In this RCT, we found a modest improvement with respect to analgesia in patients receiving PNB compared with those receiving PAI-R, but not compared with those who had PAI-L. Secondary analyses suggested that PNB or PAI-L provides superior postoperative analgesia compared with PAI-R. For primary total hip arthroplasty, a multimodal analgesic regimen including PNB or PAI-L provides opioid-limiting analgesia. Level of Evidence: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Reliable outcomes and survivorship of primary total knee arthroplasty for osteonecrosis of the knee
Mehrotra, Kapil, Pagnano, Mark W. , Chalmers, Brian P. , Mehrotra, Kapil G, Sierra, Rafael J. , Taunton, Michael J. , Abdel, Matthew P.

The Bone & Joint Journal | November 1, 2019 | Volume: 101-B | Issue: 11 | Pages: 1356-1361

10.1302/0301-620x.101b11.bjj-2019-0576.r1 Get It

AimsKnee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results.Patients and MethodsIn total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2(18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation.ResultsSurvivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening.ConclusionContemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356–1361.
Extensor Mechanism Reconstruction with Use of Marlex Mesh
Abdel, Matthew P. , Pagnano, Mark W. , Perry, Kevin I. , Hanssen, Arlen D. , Abdel, Matthew P

JBJS Essential Surgical Techniques | June 28, 2019 | Volume: 9 | Issue: 2 | Pages: e21

10.2106/jbjs.st.18.00106 Get It

Background: Marlex mesh reconstruction of the extensor mechanism via a stepwise surgical approach is a viable option to treat disruption of the extensor mechanism after total knee arthroplasty (TKA). Description: Extensor mechanism reconstruction with mesh involves a stepwise surgical approach with a particular monofilament polypropylene mesh (Marlex; C.R. Bard). Prior to incision, the 10 × 14-in (25 × 36-cm) sheet of Marlex mesh is rolled onto itself 8 to 10 times and sewn together. If the tibia is not being revised, a burr is utilized to create a trough in the tibia. Five centimeters of the tapered portion of the mesh are predipped in bone cement. The remaining cement is inserted into the trough. The tapered portion of the mesh is inserted into the tibial trough, ensuring that the mesh is fully seated. After the cement has cured, a lag screw is placed across the mesh and cement and into host bone. If the tibia is being revised at the time of the Marlex mesh reconstruction, the 5 cm of predipped mesh is placed anteriorly in the medullary canal in line with the tibial crest. The remaining procedure is similar regardless of whether the components are revised. At the level of the joint, it is essential to ensure that the mesh is covered with host tissue. Next, the proximal reconstruction, which involves mobilizing the vastus lateralis and vastus medialis obliquus (VMO) distally by releasing all ventral and dorsal soft-tissue adhesions off the muscle bellies, is completed. Finally, the mesh is unitized to the vastus lateralis. With the limb maintained in full extension, the mesh is pulled directly proximally while another assistant pulls the vastus lateralis distally and medially. The vastus lateralis is deep, and the mesh is directly on top of it. Multiple nonabsorbable sutures are placed through the mesh and vastus lateralis. The VMO is then pulled distally and laterally over the mesh (which is now unitized to the vastus lateralis) by an assistant. Multiple nonabsorbable sutures (usually 8) are placed through the VMO, through the mesh, and through the vastus lateralis, unitizing the entire construct. Alternatives: Nonoperative treatments include a drop-lock hinge brace or knee immobilizer. Operative treatments include whole extensor mechanism allograft reconstruction or Achilles tendon allograft reconstruction. Rationale: The procedure avoids the limitations of allograft with regard to availability, cost, and risk of disease transmission. The technique is reproducible and cost-effective, and it has excellent functional and survivorship outcomes.
Total Knee Arthroplasty After High Tibial Osteotomy Results in Excellent Long-Term Survivorship and Clinical Outcomes
Chalmers, Brian P. , Limberg, Afton K. , Tibbo, Meagan E. , Perry, Kevin I. , Pagnano, Mark W. , Abdel, Matthew P. , Abdel, Matthew P

Journal of Bone and Joint Surgery | June 6, 2019 | Volume: 101 | Issue: 11 | Pages: 970-978

10.2106/jbjs.18.01060 Get It

Background: Some prior reports of total knee arthroplasty after high tibial osteotomy have shown high rates of aseptic loosening. As such, the goal of this study was to analyze the outcomes of contemporary total knee arthroplasty after high tibial osteotomy, with particular emphasis on survivorship free from aseptic loosening, any revision, and any reoperation; complications; radiographic results; and clinical outcomes. Methods: We retrospectively reviewed 207 patients who underwent 231 total knee arthroplasties using cemented prostheses after high tibial osteotomy from 2000 to 2012 through our total joint registry: 87% were after a closing-wedge osteotomy and 13% were after an opening-wedge osteotomy. The mean follow-up from total knee arthroplasty was 8 years. At the time of the total knee arthroplasty, the mean age was 64 years and the mean body mass index was 31 kg/m 2 . The majority of total knee arthroplasties had a posterior-stabilized design (93%), and 4% had a varus-valgus constraint design. Tibial stems were utilized in 8% of cases. Bivariate and multivariate Cox regression analyses were utilized to analyze risk factors for poorer survival. Results: At 10 years, survivorship free from aseptic loosening was 97%, survivorship free from any revision was 90%, and survivorship free from any reoperation was 85%. Fifteen patients (15 total knee arthroplasties [6%]) underwent aseptic revision, most commonly for instability (3%), aseptic loosening (2%), and periprosthetic fracture (1%). On bivariate analysis, patient age of <60 years was a significant risk factor for poorer revision-free survival (hazard ratio, 2.9; p = 0.02); on multivariate analysis, younger age was the only significant risk factor for revision (p = 0.04). There were 14 complications (6%), the most common being a manipulation under anesthesia in 9 cases (4%). No unrevised total knee arthroplasties had definitive radiographic evidence of loosening. Knee Society scores improved from a mean preoperative score of 59 points to a mean postoperative score of 93 points (p < 0.001). Conclusions: Contemporary total knee arthroplasty with a cemented prosthesis after high tibial osteotomy demonstrated excellent long-term durability, with 10-year survivorship free from aseptic loosening of 97%. There was reliable improvement in clinical outcomes, but perfect knee balance was sometimes challenging, as reflected by a 4% prevalence of manipulation under anesthesia and a 3% prevalence of revision for instability. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Total knee arthroplasty after distal femoral osteotomy long-term survivorship and clinical outcomes
Limberg, Afton K. , Athey, Alexander G., Perry, Kevin I. , Pagnano, Mark W. , Chalmers, Brian P. , Abdel, Matthew P.

The Bone & Joint Journal | June 1, 2019 | Volume: 101-B | Issue: 6 | Pages: 660-666

10.1302/0301-620x.101b6.bjj-2018-1334.r2 Get It

AimsThere is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome.Patients and MethodsWe retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m2(20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had metaphyseal fixation (e.g. cones or sleeves), 16% needed a femoral stem.ResultsThe ten-year survivorship was 95% with aseptic loosening as the endpoint, 88% with revision for any reason as the endpoint, and 81% with re-operation for any reason as the endpoint. Three TKAs were revised for instability (n = 2) and aseptic tibial loosening (n = 1). No femoral component was revised for aseptic loosening. Patients under the age of 50 years were at greater risk of revision for any reason (hazard ratio 7; p = 0.03). There were two additional re-operations (6%) and four complications (13%), including three manipulations under anaesthetic (MUA; 10%). The Knee Society scores improved from a mean of 50 preoperatively (32 to 68) to a mean of 93 postoperatively (76 to 100; p < 0.001).ConclusionA cemented posterior-stabilized TKA has an 88% ten-year survivorship with revision for any reason as the endpoint. No femoral component was revised for aseptic loosening. Patients under the age of 50 years have a greater risk of revision. The clinical outcome was significantly improved but balancing the knee was challenging in 13% of TKAs requiring VVC. Overall, 10% of TKAs needed an MUA, and 6% of TKAs were revised for instability. Cite this article: Bone Joint J 2019;101-B:660–666.
Uniformly low serum cobalt levels after modular dual-mobility total hip arthroplasties with ceramic heads
Mangold, D. G., Hanssen, Arlen D. , Pagnano, Mark W. , Trousdale, Robert T. , Chalmers, Brian P. , Abdel, Matthew P.

The Bone & Joint Journal | May 31, 2019 | Volume: 101-B | Issue: 6_Supple_B | Pages: 57-61

10.1302/0301-620x.101b6.bjj-2018-1403.r1 Get It

Aims Modular dual-mobility constructs reduce the risk of dislocation after revision total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chromium (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the early- to mid-term serum Co and Cr levels after modular dual-mobility components were used in revision and complex primary THAs, and specifically included patients revised for ALTR. Patients and Methods Serum Co and Cr levels were measured prospectively in 24 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. The mean age was 63 years (35 to 83), with 13 patients (54%) being female. The mean follow-up was four years (2 to 7). Indications for modular dual-mobility were prosthetic joint infection treated with two-stage exchange and subsequent reimplantation (n = 8), ALTR revision (n = 7), complex primary THA (n = 7), recurrent instability (n = 1), and periprosthetic femoral fracture (n = 1). The mean preoperative Co and Cr in patients revised for an ALTR were 29.7 μg/l (2 to 146) and 21.5 μg/l (1 to 113), respectively. Results Mean Co and Cr levels were 0.30 μg/l and 0.76 μg/l, respectively, at the most recent follow-up. No patient had a Co level ≥ 1 μg/l. Only one patient had a Cr level ≥ 1 μg/l. That patient’s Cr level was 12 μg/l at 57 months after revision THA for ALTR (and decreased ten-fold from a preoperative Cr of 113 μg/l). Conclusion At a mean of four years, no patient with a modular dual-mobility construct and ceramic femoral head had elevated Co levels, including seven patients revised specifically for ALTR. While further studies are required, we support the selective use of a modular dual-mobility construct in revision and complex primary THAs for patients at high risk for instability. Cite this article: Bone Joint J 2019;101-B(6 Supple B):57–61.
Intravenous tranexamic acid safely and effectively reduces transfusion rates in revision total hip arthroplasty
Hines, Jolaine, Hernandez, N. M., Amundson, Adam W. , Pagnano, Mark W. , Sierra, Rafael J. , Abdel, Matthew P.

The Bone & Joint Journal | May 31, 2019 | Volume: 101-B | Issue: 6_Supple_B | Pages: 104-109

10.1302/0301-620x.101b6.bjj-2018-1376.r1 Get It

Aims Tranexamic acid (TXA) has been shown to significantly reduce transfusion rates in primary total hip arthroplasties (THAs), but high-quality evidence is limited in the revision setting. The purpose of the current study was to compare the rate of blood transfusions and symptomatic venous thromboembolic events (VTEs) in a large cohort of revision THAs treated with or without intravenous (IV) TXA. Patients and Methods We performed a retrospective review of 3264 revision THAs (2645 patients) between 2005 and 2014, of which 1142 procedures received IV TXA (1 g at incision and 1 g at closure). The mean age in the revision group with TXA was 65 years (28 to 95), with 579 female patients (51%). The mean age in the revision group treated without TXA was 67 years (21 to 98), with 1160 female patients (55%). Outcomes analyzed included rates of transfusion and symptomatic VTEs between procedures undertaken with and without TXA. These comparisons were performed for the overall cohort, as well as within cases subcategorized for aseptic or septic aetiologies. A propensity score was developed to minimize bias between groups and utilized age at revision THA, sex, body mass index, American Society of Anesthesiologists (ASA) score, preoperative anticoagulation, and year of surgery. Results Tranexamic acid significantly and substantially reduced the rate of blood transfusions after revision THA overall from 54% to 26% (p < 0.001; adjusted relative risk (RR) 1.6; 95% confidence interval (CI) 1.3 to 1.9), with a significant reduction in both aseptic (49% to 18%; p < 0.001) and septic (73% to 53%; p = 0.04) revisions. The rate of VTE was minimal overall, with three events (0.3%) in the TXA group and four events (0.2%) in the non-TXA group. There were no significant differences in VTE rates based on TXA use or aetiology of revision. Conclusion Intravenous TXA significantly reduced transfusion rates during all-cause revision THAs, including a subgroup analysis of both aseptic and septic cohorts. Adjusted risk using propensity modelling showed no statistical difference in rates of VTEs between either group. Cite this article: Bone Joint J 2019;100-B(6 Supple B):104–109.
Two-Stage Exchange and Marlex-Mesh Reconstruction for Infection with Extensor Mechanism Disruption After Total Knee Arthroplasty
Perry, Kevin I. , Salib, Christopher G. , Larson, Dirk R. , Pagnano, Mark W. , Abdel, Matthew P. , Hanssen, Arlen D. , Abdel, Matthew P , Larson, Dirk

Journal of Bone and Joint Surgery | September 5, 2018 | Volume: 100 | Issue: 17 | Pages: 1482-1489

10.2106/jbjs.17.01439 Get It

Background: Periprosthetic joint infection (PJI) of the knee with concurrent disruption of the extensor mechanism is a devastating complication. Historically, knees with such complications have been salvaged with use of an arthrodesis or amputation. The purpose of this study was to assess the survival and functional outcomes of a 2-stage exchange arthroplasty combined with knitted monofilament polypropylene (Marlex; C.R. Bard) mesh reconstruction of the extensor mechanism. Methods: From 2000 to 2015, 16 patients underwent a 2-stage exchange arthroplasty and Marlex-mesh reconstruction for PJI with an extensor mechanism disruption. The study included 9 male patients and 7 female patients with a mean age at the time of reimplantation and mesh reconstruction of 64 years. The mean follow-up was 4 years. PJI was diagnosed on the basis of the Musculoskeletal Infection Society criteria. Clinical outcomes, including survivorship, Knee Society Score (KSS) results, and complications, were assessed. Results: Of 16 reconstructions, 13 were in place at the time of the latest follow-up. At 2 years, survivorship free of mesh failure was 86%, survivorship free of PJI was 87%, and survivorship free of PJI or mesh failure was 75%. The mean KSS improved from 48 prior to resection to 74 after mesh reconstruction and reimplantation. The mean extensor lag improved from 31° prior to resection to 3° after mesh reconstruction. Two patients required mesh revision, 1 patient required an above-the-knee amputation for complex wound complications related to reinfection, 1 patient developed a reinfection requiring irrigation and debridement, and 1 patient developed a superficial infection that required debridement. Conclusions: Two-stage exchange arthroplasty combined with Marlex-mesh reconstruction of the extensor mechanism is a viable alternative to knee arthrodesis or amputation. At 2 years, 75% of mesh reconstructions were in place and without evidence of PJI. Moreover, the functional outcomes were improved, with a negligible extensor lag. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.