Back to Authors

Joyce, Lyle D.

Mayo Clinic

Medical College of Wisconsin

Citations 31

Pulmonary Pressure Assessment with the Total Artificial Heart
Joyce, David L. , Redfield, Margaret M. , Kushwaha, Sudhir S. , Behfar, Atta , Borlaug, Barry A. , Daly, Richard C. , Sandhu, Gurpreet S. , Joyce, Lyle D., Behfar, Atta , Borlaug, Barry A

ASAIO Journal | July 25, 2017 | Volume: 64 | Issue: 3 | Pages: e34-e36

10.1097/mat.0000000000000632 Get It

Reversal of pulmonary hypertension has been observed in patients during a bridge to transplant with a left ventricular assist device. Total artificial heart (TAH) implant prevents subsequent right heart catheterization. Consequently, controversy exists over whether the prosthetic right ventricle improves or exacerbates pulmonary hypertension. A pulmonary artery (PA) pressure monitor was placed in two patients undergoing TAH implant, as a bridge to transplant. One patient had pulmonary hypertension at implant; the other had normal pulmonary pressures. Daily measurements were taken of systolic, diastolic, and mean PA pressures throughout support. Patient 1 received successful transplant after TAH support of 91 days. Systolic/diastolic (mean) PA pressures steadily decreased from 55/39 (28) mm Hg at implant to 29/18 (7) mm Hg currently. Patient 2 received support for 101 days before death due to abdominal ischemic complications. Pulmonary arterial pressures stayed consistent throughout this period, from 26/17 (20) mm Hg at implant to 23/13 (17) mm Hg at the time of death. These findings suggest that an implantable PA pressure monitor may be useful in optimizing hemodynamics and planning appropriate timing of transplant with TAH support.
Concomitant Valve-In-Valve Transcatheter Aortic Valve Replacement and Left Ventricular Assist Device Implantation
Murashita, Takashi , Joyce, David L. , Pochettino, Alberto , Stulak, John M., Joyce, Lyle D.

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | March 23, 2017 | Volume: 12 | Issue: 2 | Pages: 147-149

10.1097/imi.0000000000000360 Get It

Redo aortic valve replacement (AVR) performed simultaneously with left ventricular assist device (LVAD) implantation carries potential for increased mortality rates. Although transcatheter AVR has been used for patients with previous LVAD placement, no literature reports concomitant valve-in-valve transcatheter AVR and LVAD implantation. Our patient had severe aortic prosthetic valve deterioration and advanced heart failure. Given the risks associated with reoperative aortic valve surgery, we chose transcatheter AVR at the time of LVAD implantation. Transthoracic echocardiography results showed severe aortic prosthetic valve deterioration with moderate aortic regurgitation as well as severe left ventricular dysfunction (ejection fraction, 11%). After redosternotomy, we performed transcatheter AVR via the ascending aorta and subsequent LVAD implantation. The postoperative course was uneventful. Generally, patients with structural deterioration of a bioprosthetic valve who report for LVAD therapy present considerable challenges to the surgeon. Concomitant transcatheter AVR offers a less-invasive alternative to surgical AVR that minimizes ischemic injury to myocardium.
Early Gains in Renal Function Following Implantation of HeartMate II Left Ventricular Assist Devices May Not Persist to One Year
Hasin, Tal , Grupper, Avishay , Maleszewski, Joseph J. , Li, Zhuo , Topilsky, Yan , Frantz, Robert P. , Edwards, Brooks S., Pereira, Naveen L. , Maltais, Simon, Stulak, John M., Joyce, Lyle D., Daly, Richard C. , Park, Soon J., Kushwaha, Sudhir S. , Dillon, John , Frantz, Robert P , Topilsky, Yan

ASAIO Journal | January 21, 2017 | Volume: 63 | Issue: 4 | Pages: 401-407

10.1097/mat.0000000000000511 Get It

Renal function improves early after left ventricular assist device (LVAD) implantation but later decline has been observed. We sought to determine the occurrence and evaluate possible causes for this decline. In 62 consecutive patients with HeartMateII LVAD with available calculated glomerular filtration rate (GFR, ml/min/1.73 m2) 1 year after implant, GFR was assessed repeatedly and possible predictors for decline from 3 to 12 months were investigated. Post-mortem renal specimens for patients supported with an LVAD were evaluated. GFR 54.5 ± 19.5 at admission increased to 66.4 ± 22.3 preoperatively and to 79.2 ± 30.1 ~1 month after implantation. Subsequently at ~3 months GFR declined to 74.7 ± 25.4, at ~6 months to 68.8 ± 23.1, and ~1 year after implant to 63.9 ± 17.7. Glomerular filtration rate at 1 year was significantly lower (p < 0.0001, p < 0.0001, p = 0.005) than GFR 1, 3, and 6 months after implant. Early rise in GFR after surgery was not associated with late decline. Shorter bypass time (β = −0.09, p = 0.048) and higher albumin 3 months after LVAD (β = 14.4, p = 0.025) were significantly associated with less later decline in GFR. Arteriosclerosis was identified in autopsy renal specimens. In conclusion, early gains in renal function after LVAD implant are not sustained in many patients. Patient, device, and operative factors may influence long-term renal function in these patients.
Sex Related Differences in the Risk of Antibody-Mediated Rejection and Subsequent Allograft Vasculopathy Post-Heart Transplantation: A Single-Center Experience
Grupper, Avishay , Nestorović, Emilija , Daly, Richard C. , Milić, Nataša , Joyce, Lyle D., Stulak, John M., Joyce, David L. , Edwards, Brooks S., Pereira, Naveen L. , Kushwaha, Sudhir S. , Milic, N

Transplantation Direct | September 14, 2016 | Volume: 2 | Issue: 10 | Pages: e106

10.1097/txd.0000000000000616 Get It

Background Pregnancies may result in antibodies against HLA, a risk factor for antibody-mediated rejection (AMR) and subsequent cardiac allograft vasculopathy (CAV) after heart transplantation (HTx). The aim of this study was to evaluate sex differences in the incidence of AMR events and subsequent risk of CAV among HTx recipients. Methods The study comprised 160 patients (51 [32%] women) who underwent HTx in 2008 to 2014. The cumulative effect of AMR events was calculated by AMR score (sum of myocardial biopsy grading divided by number of biopsies taken during 3 years post-HTx). Results Females had higher levels of anti-HLA I antibodies pre-HTx compared to males which was associated with a history of pregnancies, total number of children and with a higher AMR score at 6 months post-HTx (P < 0.05). Women demonstrated a significant increase in the total incidence of AMR events (27 vs. 7%, P = 0.001) and in AMR scores at 6, 12, 24 and 36 months post-HTx compared to men (P < 0.05). There were no differences in cellular rejection between the groups. A history of AMR events was associated with a significantly increased risk of severe CAV onset (hazard ratio, 7.0; 95% confidence interval, 1.5-31.5; P = 0.012). Conclusions Women are at higher risk for AMR post-HTx which subsequently increases their risk for CAV. Females recipients may benefit from closer surveillance to identify AMR at an earlier stage post-HTx, and targeted immunosuppressive therapy to attenuate the development of CAV.
Management of Peripheral Pulmonary Emboli with the Use of Transvenous Catheter-Directed Thrombolysis and Right Ventricular Assist Device
Said, Sameh M. , Salhab, Khaled F., Joyce, Lyle D.

Journal of Cardiac Surgery | September 10, 2013 | Volume: 28 | Issue: 5 | Pages: 611-615

10.1111/jocs.12185 Get It

Dual Anti-platelet Therapy After Coronary Artery Bypass Grafting: Is There Any Benefit? A Systematic Review and Meta-Analysis
Shah, Ishan K., Altarabsheh, Salah E. , Erwin, Patricia J., Boilson, Barry A. , Park, Soon J., Joyce, Lyle D., Deo, Salil V. , Dunlay, Shannon M. , Altarabsheh, Salah

Journal of Cardiac Surgery | March 15, 2013 | Volume: 28 | Issue: 2 | Pages: 109-116

10.1111/jocs.12074 Get It

Multiple Arterial Grafts Improve Late Survival of Patients Undergoing Coronary Artery Bypass Graft Surgery
Locker, Chaim, Schaff, Hartzell V. , Joyce, Lyle D., Park, Soon J., Burkhart, Harold M. , Suri, Rakesh M. , Greason, Kevin L. , Stulak, John M., Daly, Richard C. , Li, Zhuo , Dearani, Joseph A. , Li, Zhuo Ya , Schaff, Hartzell

Circulation | July 19, 2012 | Volume: 126 | Issue: 9 | Pages: 1023-1030

10.1161/circulationaha.111.084624 Get It

Background— Use of the left internal mammary artery (LIMA) in multivessel coronary artery disease improves survival after coronary artery bypass graft surgery; however, the survival benefit of multiple arterial (MultArt) grafts is debated. Methods and Results— We reviewed 8622 Mayo Clinic patients who had isolated primary coronary artery bypass graft surgery for multivessel coronary artery disease from 1993 to 2009. Patients were stratified by number of arterial grafts into the LIMA plus saphenous veins (LIMA/SV) group (n=7435) or the MultArt group (n=1187). Propensity score analysis matched 1153 patients. Operative mortality was 0.8% (n=10) in the MultArt and 2.1% (n=154) in the LIMA/SV ( P =0.005) group, which was not statistically different ( P =0.996) in multivariate analysis or the propensity-matched analysis ( P =0.818). Late survival was greater for MultArt versus LIMA/SV (10- and 15-year survival rates were 84% and 71% versus 61% and 36%, respectively [ P <0.001], in unmatched groups and 83% and 70% versus 80% and 60%, respectively [ P =0.0025], in matched groups). MultArt subgroups with bilateral internal mammary artery/SV (n=589) and bilateral internal mammary artery only (n=271) had improved 15-year survival (86% and 76%; 82% and 75% at 10 and 15 years [ P <0.001]), and patients with bilateral internal mammary artery/radial artery (n=147) and LIMA/radial artery (n=169) had greater 10-year survival (84% and 78%; P <0.001) versus LIMA/SV. In multivariate analysis, MultArt grafts remained a strong independent predictor of survival (hazard ratio, 0.79; 95% confidence interval, 0.66–0.94; P =0.007). Conclusions— In patients undergoing isolated coronary artery bypass graft surgery with LIMA to left anterior descending artery, arterial grafting of the non–left anterior descending vessels conferred a survival advantage at 15 years compared with SV grafting. It is still unproven whether these results apply to higher-risk subgroups of patients.
The Off-Pump Implantation of an Apicoaortic Valved Graft is Safe and Has No Negative Impact on Coronary Flow and Hemodynamics
Karapanos, N. Tsirikos, Suddendorf, Scott H., Li, Zhuo , Huebner, Marianne , Park, Soon J., Joyce, Lyle D., Daly, Richard C.

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | October 28, 2011 | Volume: 6 | Issue: 5 | Pages: 298-304

10.1097/imi.0b013e31823735ba Get It

Objective To determine the hemodynamic effect of an off-pump Apicoaortic valved graft (AAVG) implantation, we performed a quantitative coronary flow analysis in a swine model of severe aortic stenosis. Methods In 10 swine, cardiac output, coronary flow, right common carotid artery flow, and internal mammary artery flow were measured along with left and right ventricular pressures and aortic and pulmonary artery pressures. A novel AAVG was implanted off-pump on the left ventricular (LV) apex using a specially designed implantation tool and anastomosed to the descending thoracic aorta. Aortic flow was measured proximally and distally of the AAVG-to-descending thoracic aorta anastomosis. After AAVG implantation, epicardial echo confirmed occlusion of the LV outflow tract by a valvuloplasty balloon. Baseline simultaneous measurements of all parameters were repeated after AAVG implantation and intravenous Dobutamine administration. Results The AAVG was implanted without any blood loss. After AAVG implantation and LV outflow tract occlusion, the aortic flow proximal to the AAVG-to-descending thoracic aorta anastomosis changed from antegrade (1508 ± 435 mL/min) to retrograde (–529 ± 241 mL/min, P < 0.001). All other measured parameters remained unchanged compared with baseline. After intravenous Dobutamine administration, LV pressure increased from 88 ± 20 to 184 ± 36 mm Hg (+209%, P < 0.0001) and coronary flow increased from 75 ± 34 to 193 ± 90 mL/min (+257%, P = 0.001). Conclusions The off-pump implantation of an AAVG is bloodless, safe, reproducible and has no negative impact on coronary flow and hemodynamics. In addition, to the best of our knowledge, this is the first study where blood flow in all coronary arteries was measured simultaneously during an AAVG implantation.
Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology
Durham, Lucian A. , Burkhart, Harold M. , Joyce, Lyle D., Cetta, Frank , Phillips, Sabrina D. , Sundareswaran, Kartik S., Farrar, David J. , Park, Soon J., Dearani, Joseph A. , Cabalka, Allison K.

World Journal for Pediatric and Congenital Heart Surgery | April 13, 2011 | Volume: 2 | Issue: 2 | Pages: 243-248

10.1177/2150135110397386 Get It

Although the Fontan procedure has been enormously successful in palliation of single-ventricle patients, many seem to experience progressive failure of the Fontan circulation over time. Ventricular assist devices (VADs) have developed into stable platforms for long-term support of adult patients with heart failure. Given the success of axial flow devices, it was hypothesized that the technology could provide clinical benefit to failing Fontan patients. The aim of this study was to use a computer model to evaluate VAD support in failing Fontan physiology. A computer model of Fontan circulation with heart failure was developed and the HeartMate II (HM II) (Thoratec Corp) axial flow ventricular assist device was connected to this model in a systemic configuration to examine its impact. Cardiac catheterization data from 7 patients (8 catheterization studies) with failing Fontan physiology were applied to this model to evaluate the impact of using the HM II in this manner. When the HM II was used in a systemic configuration at 8000 rpm, there was a 35% decrease in the systemic venous pressure in the Fontan circuit and a 63% decrease in pulmonary capillary wedge pressure with a resultant 41% increase in CI. The model also predicted patient-specific parameters where the VAD may not benefit the patient, such as fixed elevated pulmonary vascular resistance, low systemic ventricular end-diastolic pressure, and high unresponsive systemic vascular resistance. These data suggest a potential benefit from application of axial flow VAD technology in the management of failing Fontan physiology. Clinical correlation will allow for refinement of this model as a predictive tool in discerning which patients may benefit from placement of a VAD and what issues must be addressed prior to implanting the device.
Left Ventricular Assist Device Therapy in Patients With Restrictive and Hypertrophic Cardiomyopathy
Topilsky, Yan , Pereira, Naveen L. , Shah, Dipesh K. , Boilson, Barry A. , Schirger, John A., Kushwaha, Sudhir S. , Joyce, Lyle D., Park, Soon J., Topilsky, Yan , Topilsky, Yan

Circulation: Heart Failure | February 9, 2011 | Volume: 4 | Issue: 3 | Pages: 266-275

10.1161/circheartfailure.110.959288 Get It

Background— Left ventricular assist device (LVAD) is being increasingly used in patients with end-stage dilated and ischemic cardiomyopathy. There have been no clinical trials addressing the use of LVAD therapy in patients with end-stage heart failure caused by restrictive (RCM) or hypertrophic cardiomyopathy (HCM). The purpose of this study was therefore to analyze the outcome of LVAD therapy in these patients. Methods and Results— Eighty-three patients received continuous axial flow LVAD (Heart mate II, Thoratec, Pleasanton, CA) from February 2007 to May 2010 at our institution. We analyzed the baseline characteristics and surgical and long-term impact of LVAD therapy in 8 patients with RCM or HCM and compared their outcomes with the 75 patients with dilated and ischemic cardiomyopathy. Compared with patients with ischemic or dilated cardiomyopathy, patients with RCM and HCM have significantly smaller left ventricular end-diastolic dimensions (52.5±6 mm versus 68.6±8 mm; P <0.0001) and increased thickness of septal (16 [12, 19] mm versus 10[8.5, 11] mm, P =0.0003) and higher left ventricular ejection fraction (21 [20, 36]% versus 17 [15, 22]%; P =0.0009). We found no difference in early mortality (12.5% versus 9.3%, P =0.57) or length of hospital stay (11 [8, 45] days versus 18.5 [12.2, 27.7] days; P =0.51) between the 2 groups. The right atrial pressure was higher (18 [15, 20] mm Hg versus 12 [9, 15] mm Hg, P =0.03), and pump flow was lower (4.3 [3.8, 4.5] L versus 5.2 [4.7, 5.5] L, P =0.001) after LVAD implantation in patients with RCM and HCM. Central venous catheter related infections were more common in patients with RCM and HCM (87.5% versus 44.5%, P =0.006). There was no difference in the total number of blood units transfused. Median (min, max) follow-up duration after LVAD implantation was 166 [1, 1044] days. The 1-year actuarial survival rate was not different between the 2 groups (87.5% [95% confidence interval, 52.9% to 97.8%] versus 73.2 [95% confidence interval, 60% to 85%]; P =0.77). Conclusions— Our preliminary data show that patients with end-stage heart failure caused by RCM or HCM may benefit from continuous axial flow LVAD therapy. This small study suggests that mortality is comparable with those patients who have dilated or ischemic cardiomyopathy, but right heart failure, prolonged inotropic use, and central venous catheter infections are more common in patients with RCM and HCM who were treated with LVAD. Because of the small numbers the differences should be interpreted cautiously, and prospective clinical trials would be required to recommend this therapy for these patients as bridge to transplantation or destination treatment.