Anderson, James H.

https://orcid.org/0000-0001-7138-939X

Mayo Clinic

Know Labs, Inc., Seattle, Washington, USA

Citations 3

A Glycemic Status Classification Model Using a Radiofrequency Noninvasive Blood Glucose Monitor
Anderson, James H. , Currie, Kaptain, Bui, Connor, Klyve, Dominic , Karim, Fazle , Currie, Kaptain , Klyve, Dominic , BUI, CONNOR, Somers, Virend K.

Diabetes Technology & Therapeutics | July 1, 2024 | Volume: 26 | Issue: 12 | Pages: 979-983

10.1089/dia.2024.0170 Get It

Despite significant efforts in the development of noninvasive blood glucose (BG) monitoring solutions, delivering an accurate, real-time BG measurement remains challenging. We sought to address this by using a novel radiofrequency (RF) glucose sensor to noninvasively classify glycemic status. The study included 31 participants aged 18–65 with prediabetes or type 2 diabetes and no other significant medical history. During control sessions and oral glucose tolerance test sessions, data were collected from both a RF sensor that rapidly scans thousands of frequencies and concurrently from a venous blood draw measured with an US Food and Drug Administration (FDA)-cleared glucose hospital meter system to create paired observations. We trained a time series forest machine learning model on 80% of the paired observations and reported results from applying the model to the remaining 20%. Our findings show that the model correctly classified glycemic status 93.37% of the time as high, normal, or low.
Non-invasive Blood Glucose Monitoring Using a Radiofrequency Sensor and a Machine Learning Model
Klyve, Dominic , Anderson, James H. , Curie, Kaptain, Pandya, Kinara, Ward, Carl, Somers, Virend K.

Physiology | May 21, 2024 | Volume: 39 | Issue: S1 | Pages: No page available

10.1152/physiol.2024.39.s1.1179 Get It

Diabetes Mellitus (DM) affects over 530 million people globally and is a condition characterized by high blood glucose (BG) that can result in severe long-term health consequences if poorly managed. To mitigate the risks associated with DM, it is crucial to regulate BG levels through regular monitoring. Current methods of monitoring BG come with drawbacks in the form of pain and expense. With the rapid increase in prevalence of DM, there is an increasing need for economical, accurate, and non-invasive continuous measures of BG. Here we present a validation for a novel sensor that rapidly scans through a wide range of radio frequencies (RF) and uses machine learning (ML) techniques for the purpose of non-invasive BG measurement. After model training, the RF sensor and ML techniques employed in this study can predict BG at a level significantly better than chance, as shown below. Data were collected from 13 healthy participants over a series of tests lasting 2 – 3 hours. During each test, participants placed their forearm on an RF sensor that measured their BG levels using sweeps across the 500 MHz – 1500 MHz range at 0.1 MHz intervals. Participants ingested 37.5 grams of glucose solution to generate BG readings across normoglycemic and hyperglycemic ranges. Each sweep took approximately 22 seconds, including a one second pause between sweeps. Across 110 tests, we collected 3,311 BG observations. Concurrent measurements from a Continuous Glucose Monitor (CGM) were taken as reference. Data were divided using a 60-20-20 (training-validation-test) split and trained on a Light Gradient-Boosting Machine (lightGBM) model to predict BG values. A ‘blind’ evaluation of model performance was determined using the held-out test dataset. We predicted BG values in the held-out test dataset with a Mean Absolute Relative Difference (MARD) of 10.8% in the normoglycemic range and 15.9% in the hyperglycemic range (11.27% overall MARD). These results were significantly better than a chance model (two-sample t-test, p <0.01). In a Surveillance Error Grid analysis of model accuracy, 89.0% of predictions fell in Risk Level 0, 10.1% in Risk Level 1, and 0.9% in Risk Level 2. These results demonstrate that the novel RF sensor and ML techniques described can predict a reference BG value in the population under study. More research is underway to refine and expand these methods using a gold-standard blood glucose reference device and among a broader participant population with an expanded glucose range. DK and VS are consultants for and own stock in Know Labs. JA and KC are employed by and have stock options in Know Labs. CW and KP are consultants for Know Labs. NA. This is the full abstract presented at the American Physiology Summit 2024 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.
Detecting Unique Analyte-Specific Radio Frequency Spectral Responses in Liquid Solutions—Implications for Non-Invasive Physiologic Monitoring
Klyve, Dominic , Anderson, James H. , Lorentz, George, Somers, Virend K.

Sensors | May 17, 2023 | Volume: 23 | Issue: 10 | Pages: 4817

10.3390/s23104817 Get It

With rising healthcare costs and the rapid increase in remote physiologic monitoring and care delivery, there is an increasing need for economical, accurate, and non-invasive continuous measures of blood analytes. Based on radio frequency identification (RFID), a novel electromagnetic technology (the Bio-RFID sensor) was developed to non-invasively penetrate inanimate surfaces, capture data from individual radio frequencies, and convert those data into physiologically meaningful information and insights. Here, we describe groundbreaking proof-of-principle studies using Bio-RFID to accurately measure various concentrations of analytes in deionized water. In particular, we tested the hypothesis that the Bio-RFID sensor is able to precisely and non-invasively measure and identify a variety of analytes in vitro. For this assessment, varying solutions of (1) water in isopropyl alcohol; (2) salt in water, and (3) commercial bleach in water were tested, using a randomized double-blind trial design, as proxies for biochemical solutions in general. The Bio-RFID technology was able to detect concentrations of 2000 parts per million (ppm), with evidence suggesting the ability to detect considerably smaller concentration differences.