Back to Authors

Klyve, Dominic

https://orcid.org/0000-0002-4424-3130

Mayo Clinic

Central Washington University

Citations 5

Cost-effectiveness and environmental impact of artificial intelligence-assisted colonoscopy with the resect-and-discard strategy: a microsimulation study
Hernandez, Lyndon V. , Wallace, Michael B. , Renteln, Daniel von , Sherman, Jodi, Bhutani, Manoop S. , Guda, Nalini M. , Espinosa, Wendell, Klyve, Dominic , Manahan, Theo, Pohl, Heiko, von Renteln, Daniel , Wallace, Michael B , Sherman, Jodi D. , Manahan, Theodore, Pohl, Heiko

Endoscopy | August 12, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/a-2936-0598 Get It

Abstract: Background Artificial intelligence (AI)-assisted colonoscopy reduces costs in colorectal cancer screening, but its incremental value relative to non-AI resect-and-discard (RD) strategies for diminutive polyps (≤ 5 mm) remain unclear. We aimed to compare the clinical, economic, and environmental outcomes of AI-assisted and non-AI RD strategies with standard of care (SoC). Methods In our Markov model simulating 6 million individuals aged ≥45 years undergoing screening colonoscopy, 4 strategies were evaluated: SoC, non-AI RD, CADe-assisted RD (CADe-RD), and CADe+CADx-assisted RD (CADe+CADx-RD). The primary outcome was total quality-adjusted life years (QALYs), with secondary outcomes including cost and carbon dioxide (CO₂) emissions. Results Non-AI RD achieved the lowest total cost ($36.6B) and carbon emissions (0.90 million kg CO₂), while yielding the highest QALYs (51.37 million), although differences in QALYs across strategies were small (<0.01%). CADe-RD and CADe+CADx-RD remained cost-saving relative to SoC ($36.9B and $37.4B vs $37.8B, respectively) but were associated with higher costs than non-AI RD. CADe modestly increased adenoma detection without improving QALYs, while the addition of CADx increased costs and emissions and resulted in slightly lower QALYs. Sensitivity analysis showed that CADe+CADx-RD matched or exceeded CADe-RD QALYs only within a limited region of high diagnostic performance. At currently reported CADx performance levels, CADe+CADx-RD yielded lower QALYs and higher costs than CADe-RD. CADe+CADx-RD achieved non-inferiority in QALYs relative to CADe-RD only within a limited region of high diagnostic performance. Conclusions In our non-deterministic model, non-AI RD provided the optimal balance of clinical benefit, cost savings, and lowest environmental impact.
A Glycemic Status Classification Model Using a Radiofrequency Noninvasive Blood Glucose Monitor
Anderson, James H. , Currie, Kaptain, Bui, Connor, Klyve, Dominic , Karim, Fazle , Currie, Kaptain , Klyve, Dominic , BUI, CONNOR, Somers, Virend K.

Diabetes Technology & Therapeutics | July 1, 2024 | Volume: 26 | Issue: 12 | Pages: 979-983

10.1089/dia.2024.0170 Get It

Despite significant efforts in the development of noninvasive blood glucose (BG) monitoring solutions, delivering an accurate, real-time BG measurement remains challenging. We sought to address this by using a novel radiofrequency (RF) glucose sensor to noninvasively classify glycemic status. The study included 31 participants aged 18–65 with prediabetes or type 2 diabetes and no other significant medical history. During control sessions and oral glucose tolerance test sessions, data were collected from both a RF sensor that rapidly scans thousands of frequencies and concurrently from a venous blood draw measured with an US Food and Drug Administration (FDA)-cleared glucose hospital meter system to create paired observations. We trained a time series forest machine learning model on 80% of the paired observations and reported results from applying the model to the remaining 20%. Our findings show that the model correctly classified glycemic status 93.37% of the time as high, normal, or low.
Non-invasive Blood Glucose Monitoring Using a Radiofrequency Sensor and a Machine Learning Model
Klyve, Dominic , Anderson, James H. , Curie, Kaptain, Pandya, Kinara, Ward, Carl, Somers, Virend K.

Physiology | May 21, 2024 | Volume: 39 | Issue: S1 | Pages: No page available

10.1152/physiol.2024.39.s1.1179 Get It

Diabetes Mellitus (DM) affects over 530 million people globally and is a condition characterized by high blood glucose (BG) that can result in severe long-term health consequences if poorly managed. To mitigate the risks associated with DM, it is crucial to regulate BG levels through regular monitoring. Current methods of monitoring BG come with drawbacks in the form of pain and expense. With the rapid increase in prevalence of DM, there is an increasing need for economical, accurate, and non-invasive continuous measures of BG. Here we present a validation for a novel sensor that rapidly scans through a wide range of radio frequencies (RF) and uses machine learning (ML) techniques for the purpose of non-invasive BG measurement. After model training, the RF sensor and ML techniques employed in this study can predict BG at a level significantly better than chance, as shown below. Data were collected from 13 healthy participants over a series of tests lasting 2 – 3 hours. During each test, participants placed their forearm on an RF sensor that measured their BG levels using sweeps across the 500 MHz – 1500 MHz range at 0.1 MHz intervals. Participants ingested 37.5 grams of glucose solution to generate BG readings across normoglycemic and hyperglycemic ranges. Each sweep took approximately 22 seconds, including a one second pause between sweeps. Across 110 tests, we collected 3,311 BG observations. Concurrent measurements from a Continuous Glucose Monitor (CGM) were taken as reference. Data were divided using a 60-20-20 (training-validation-test) split and trained on a Light Gradient-Boosting Machine (lightGBM) model to predict BG values. A ‘blind’ evaluation of model performance was determined using the held-out test dataset. We predicted BG values in the held-out test dataset with a Mean Absolute Relative Difference (MARD) of 10.8% in the normoglycemic range and 15.9% in the hyperglycemic range (11.27% overall MARD). These results were significantly better than a chance model (two-sample t-test, p <0.01). In a Surveillance Error Grid analysis of model accuracy, 89.0% of predictions fell in Risk Level 0, 10.1% in Risk Level 1, and 0.9% in Risk Level 2. These results demonstrate that the novel RF sensor and ML techniques described can predict a reference BG value in the population under study. More research is underway to refine and expand these methods using a gold-standard blood glucose reference device and among a broader participant population with an expanded glucose range. DK and VS are consultants for and own stock in Know Labs. JA and KC are employed by and have stock options in Know Labs. CW and KP are consultants for Know Labs. NA. This is the full abstract presented at the American Physiology Summit 2024 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.
Detecting unique analyte-specific radio frequency spectral responses in liquid solutions -- implications for non-invasive physiologic monitoring
Klyve, Dominic , Bosua, Phil, Somers, Virend K. , Anderson, James

Physiology | May 29, 2023 | Volume: 38 | Issue: S1 | Pages: No page available

10.1152/physiol.2023.38.s1.5796114 Get It

With rising healthcare costs and the rapid increase in remote physiologic monitoring and care delivery, there is increasing need for economical, accurate and non-invasive continuous measures of blood analytes. Based on radio-frequency identification (RFID), we have developed a novel electromagnetic platform technology (the Bio-RFID platform) to non-invasively penetrate inanimate surfaces, capture data from individual radio frequencies, and convert those data into physiologically meaningful information and insights. Here we describe ground-breaking proof-of-principle studies using Bio-RFID to accurately measure various concentrations of analytes in deionized water. The in vitro Bio-RFID platform consists of an acrylic cuvette in the shape of a 4 inch x 4 inch x 8 inch rectangular prism mounted on the Bio-RFID sensor. This apparatus is in turn mounted on a balance that allows the determination of the mass of the analyte being scanned to within 0.1g. The hardware scans through several thousand radio frequencies and sends the data to proprietary software running on a laptop computer. The software displays a spectral scan known as the Bio-RFID signature of the analyte and computes a similarity metric to compare different signatures.We tested the hypothesis that the Bio-RFID platform is able to precisely and non-invasively measure and identify a variety of analytes in vitro. For this assessment, varying solutions of 1) water in isopropyl alcohol; 2) salt in water; and 3) commercial bleach in water were tested, using a randomized double-blind trial design, as proxies for biochemical solutions in general. The Bio-RFID technology was able to detect concentrations of 2000 parts per million (ppm), with evidence suggesting the ability to detect considerably smaller concentration differences. The novel application of a Bio-RFID electromagnetic platform technology accurately detects, measures, and quantifies specific molecules in liquid. While these findings have in vitro commercial applications, these proof-of-principle studies provide strong support for the application of Bio-RFID technology for non-invasive bio-monitoring of physiologically and medically relevant analytes, such as alcohol and glucose, in the human body. These studies were funded by a grant from Know Labs to Mayo Clinic. PB and JHA are employed by Know Labs. VKS and Mayo Clinic acknowledge a financial interest in Know Labs. This is the full abstract presented at the American Physiology Summit 2023 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.
Detecting Unique Analyte-Specific Radio Frequency Spectral Responses in Liquid Solutions—Implications for Non-Invasive Physiologic Monitoring
Klyve, Dominic , Anderson, James H. , Lorentz, George, Somers, Virend K.

Sensors | May 17, 2023 | Volume: 23 | Issue: 10 | Pages: 4817

10.3390/s23104817 Get It

With rising healthcare costs and the rapid increase in remote physiologic monitoring and care delivery, there is an increasing need for economical, accurate, and non-invasive continuous measures of blood analytes. Based on radio frequency identification (RFID), a novel electromagnetic technology (the Bio-RFID sensor) was developed to non-invasively penetrate inanimate surfaces, capture data from individual radio frequencies, and convert those data into physiologically meaningful information and insights. Here, we describe groundbreaking proof-of-principle studies using Bio-RFID to accurately measure various concentrations of analytes in deionized water. In particular, we tested the hypothesis that the Bio-RFID sensor is able to precisely and non-invasively measure and identify a variety of analytes in vitro. For this assessment, varying solutions of (1) water in isopropyl alcohol; (2) salt in water, and (3) commercial bleach in water were tested, using a randomized double-blind trial design, as proxies for biochemical solutions in general. The Bio-RFID technology was able to detect concentrations of 2000 parts per million (ppm), with evidence suggesting the ability to detect considerably smaller concentration differences.