AbstractPurposeTo develop a robust 3D ultrashort‐TE (UTE) protocol that can reproducibly provide high‐quality images, assessed by the ability to yield clinically diagnostic images, and is suitable for clinical translation.Theory and MethodsBuilding on previous work, a UTE sampled with Fermat looped orthogonally encoded trajectories (FLORET) was chosen as a starting point due to its shorter, clinically reasonable scan times. Modifications to previous FLORET implementations included gradient waveform frequency limitations, a new trajectory ordering scheme, a balanced SSFP implementation, fast gradient spoiling, and full inline reconstruction. FLORET images were collected in phantoms and humans on multiple scanners and sites to demonstrate these improvements.ResultsThe updates to FLORET provided high‐quality images in phantom, musculoskeletal, and pulmonary applications. The gradient waveform modifications and new trajectory ordering scheme significantly reduced visible artifacts. Fast spoiling reduced acquisition time by 20%–28%. Across the various scanners and sites, the inline image quality was consistent and of diagnostic quality. Total image acquisition plus reconstruction time was less than 4 min for musculoskeletal and pulmonary applications with reconstructions taking less than 1 min.ConclusionRecently developed improvements for the FLORET sequence have enabled robust, high‐quality UTE acquisitions with short acquisition and reconstruction times. This enables clinical UTE imaging as demonstrated by the implementation of the sequence and acquisition on five MRI scanners, at three different sites, without the need for any additional system characterization or measurements.
Simultaneous brain and neck time‐of‐flight MRA using spiral multiband with localized quadratic encoding
AbstractPurposeTo develop a method that achieves simultaneous brain and neck time‐of‐flight (ToF) magnetic resonance angiography (MRA) within feasible scan timeframes.MethodsLocalized quadratic (LQ) encoding is efficient for both signal‐to‐noise ratio (SNR) and in‐flow enhancement. We proposed a spiral multiband LQ method to enable simultaneous intracranial and carotid ToF‐MRA within a single scan. To address the venous signal contamination that becomes a challenge with multiband (MB) ToF, tilt‐optimized non‐saturated excitation (TONE) and partial‐Fourier slice selection (PFSS) were further introduced in the LQ framework to mitigate the venous signal and improve artery contrast. A sequential spiral MB and LQ reconstruction pipeline was employed to obtain the brain‐and‐neck image volumes.ResultsThe proposed MB method was able to achieve simultaneous brain and neck ToF‐MRA within a 2:50‐min scan. The complementarily boosted SNR‐efficiency by MB and LQ acquisitions allows for the increased spatial coverage without increase in scan time or noticeable compromise in SNR. The incorporation of both TONE and PFSS effectively alleviated the venous contamination with improved small vessel sensitivity. Selection of scan parameters such as the LQ factor and flip angle reflected the trade‐off among SNR, blood contrast, and venous suppression.ConclusionsA novel MB spiral LQ approach was proposed to enable fast intracranial and carotid ToF‐MRA with minimized venous corruption. The method has shown promise in MRA applications where large spatial coverage is necessary.
Spiral inflow MRA with sliding‐slice localized quadratic encoding
Abstract Purpose This work proposes a 2D/3D hybrid inflow MRA technique for fast scanning and high SNR and contrast‐to‐noise (CNR) efficiencies. Methods Localized quadratic (LQ) encoding was combined with a sliding‐slice spiral acquisition. Inflow MRAs around the circle of Willis and the carotid bifurcations were collected on four healthy volunteers. Spiral images were deblurred without or with water–fat separation for sliding‐slice LQ (ssLQ) out‐of‐phase (OP) and Dixon inflow MRAs, respectively. Results were compared to multiple overlapping thin slab acquisitions (MOTSA) and 2D OP inflow MRAs. Noise data were also acquired with RF and gradients turned off to compute maps of SNR and SNR efficiency. Quantitative assessment of relative contrast, CNR, and CNR efficiency for flow were performed in regions of interest. Results The sliding‐slice spiral technique alone reduces scan time by 10% to 40% compared with a standard spiral acquisition scheme. The proposed spiral ssLQ OP achieves 50% higher scan speed than the spiral MOTSA with comparable SNR and CNR efficiencies, which are ∼100% higher than the Cartesian MOTSA for intracranial inflow MRAs. Spiral ssLQ Dixon inflow MRA provides better visibility for vessels around the fat compared to spiral ssLQ OP inflow MRA, with a trade‐off of scan speed. Spiral ssLQ MRA with thinner slice thickness is two to five times faster than the 2D Cartesian inflow neck MRA around the carotid bifurcations, while also achieving higher SNR efficiency. Conclusion The proposed spiral ssLQ is a fast and flexible MRA method with improved SNR and CNR efficiencies over traditional Cartesian inflow MRAs.
A field map updating algorithm to improve fat‐water spiral imaging
PurposeAn accurate field map is essential to separate fat and water signals in a dual‐echo chemical shift encoded spiral MRI scan. A rapid low‐resolution B0 map prescan is usually performed before each exam. Occasional inaccuracy in these field map estimates can lead to misclassification of the water and fat signals as well as blurring artifacts in the reconstruction. The present work proposes a self‐consistent model to evaluate residual field offsets according to the image data to improve the reconstruction quality and facilitate the scan efficiency.Theory and MethodsThe proposed method compares the phase differences of the two‐echo data after correcting for fat frequency offsets. A more accurate field map is approximated according to the phase discrepancies and improved image quality. Experiments were conducted with simulated off‐resonance on a numerical phantom, five volunteer head scans, and four volunteer abdominal scans for validation.ResultsThe initial reconstruction of the demonstrated examples exhibit blurring artifacts and misregistration of fat and water because of the inaccuracy of the field map. The proposed method updates the field map to amend the fat and water estimation and improve image quality.ConclusionsThis work presents a model to improve the quality of fat‐water imaging of the spiral MRI by estimating a better field map from the acquired data. It allows reducing the field map pre‐scans before each spiral scan under normal circumstances to increase scan efficiency.