AbstractPurposeTo develop a robust 3D ultrashort‐TE (UTE) protocol that can reproducibly provide high‐quality images, assessed by the ability to yield clinically diagnostic images, and is suitable for clinical translation.Theory and MethodsBuilding on previous work, a UTE sampled with Fermat looped orthogonally encoded trajectories (FLORET) was chosen as a starting point due to its shorter, clinically reasonable scan times. Modifications to previous FLORET implementations included gradient waveform frequency limitations, a new trajectory ordering scheme, a balanced SSFP implementation, fast gradient spoiling, and full inline reconstruction. FLORET images were collected in phantoms and humans on multiple scanners and sites to demonstrate these improvements.ResultsThe updates to FLORET provided high‐quality images in phantom, musculoskeletal, and pulmonary applications. The gradient waveform modifications and new trajectory ordering scheme significantly reduced visible artifacts. Fast spoiling reduced acquisition time by 20%–28%. Across the various scanners and sites, the inline image quality was consistent and of diagnostic quality. Total image acquisition plus reconstruction time was less than 4 min for musculoskeletal and pulmonary applications with reconstructions taking less than 1 min.ConclusionRecently developed improvements for the FLORET sequence have enabled robust, high‐quality UTE acquisitions with short acquisition and reconstruction times. This enables clinical UTE imaging as demonstrated by the implementation of the sequence and acquisition on five MRI scanners, at three different sites, without the need for any additional system characterization or measurements.
Improved pulmonary
129
Xe ventilation imaging via 3D‐spiral UTE MRI
Purpose Hyperpolarized 129 Xe MRI characterizes regional lung ventilation in a variety of disease populations, with high sensitivity to airway obstruction in early disease. However, ventilation images are usually limited to a single breath‐hold and most‐often acquired using gradient‐recalled echo sequences with thick slices (~10‐15 mm), which increases partial‐volume effects, limits ability to observe small defects, and suffers from imperfect slice selection. We demonstrate higher‐resolution ventilation images, in shorter breath‐holds, using FLORET (Fermat Looped ORthogonally Encoded Trajectories), a center‐out 3D‐spiral UTE sequence. Methods In vivo human adult ( N = 4; 2 healthy, 2 with cystic fibrosis) 129 Xe images were acquired using 2D gradient‐recalled echo, 3D radial, and FLORET. Each sequence was acquired at its highest possible resolution within a 16‐second breath‐hold with a minimum voxel dimension of 3 mm. Images were compared using 129 Xe ventilation defect percentage, SNR, similarity coefficients, and vasculature cross‐sections. Results The FLORET sequence obtained relative normalized SNR, 40% greater than 2D gradient‐recalled echo ( P = .012) and 26% greater than 3D radial ( P = .067). Moreover, the FLORET images were acquired with 3‐fold‐higher nominal resolution in a 15% shorter breath‐hold. Finally, vasculature was less prominent in FLORET, likely due to diminished susceptibility‐induced dephasing at shorter TEs afforded by UTE sequences. Conclusion The FLORET sequence yields higher SNR for a given resolution with a shorter breath‐hold than traditional ventilation imaging techniques. This sequence more accurately measures ventilation abnormalities and enables reduced scan times in patients with poor compliance and severe lung disease.