AbstractBackgroundGastrointestinal bleeding (GIB) in patients with continuous flow left ventricular assist devices (CF‐LVADs) is often related to GI angiodysplasia (GIAD). We previously reported data on VEGF inhibition with IV bevacizumab in the treatment of LVAD‐associated GIAD bleeding, and now present follow‐up data on patients treated with IV bevacizumab and/or low‐dose oral pazopanib.MethodsAll consecutive adult patients with LVAD‐associated GIB from GIAD treated with bevacizumab or pazopanib, from July 20, 2017 to June 22, 2022, were included in the analysis. Data on hospitalizations, GI endoscopic procedures, and blood transfusions were obtained from first admission for GIB up to a median of 35.7 months following treatment initiation (range 1.3–59.8 months).ResultsEleven patients (91% male, mean 69.5 ± 8.9 years) were included. Eight patients (73%) received IV bevacizumab, two patients (18%) received oral pazopanib, and one patient (9%) received bevacizumab followed by pazopanib therapy. We observed a significantly decreased number of annualized hospitalizations for GIB (median difference − 2.87, p = 0.002), blood transfusions (median difference − 20.9, p = 0.01), and endoscopies (median difference − 6.95, p = 0.007) in patients pre‐ and post‐anti‐angiogenic therapy (bevacizumab and/or pazopanib). Similarly, a significant improvement in these clinical outcomes was noted in the bevacizumab group with decreased annualized hospitalizations (median difference − 2.75, p = 0.014), blood transfusions (median difference − 24.5, p = 0.047), and number of endoscopies (median differences −6.88, p = 0.006).ConclusionAnti‐angiogenic therapy with IV bevacizumab and/or low‐dose oral pazopanib appears to provide benefits in patients with LVAD‐associated GIB with reduced hospitalizations, blood transfusions, and need for GI endoscopic procedures.
Infections in Patients With Left Ventricular Assist Devices: Current State and Future Perspectives
Mechanical circulatory support is increasingly being used as bridge-to-transplant and destination therapy in patients with advanced heart failure. Technologic improvements have led to increased patient survival and quality of life, but infection remains one of the leading adverse events following ventricular assist device (VAD) implantation. Infections can be classified as VAD-specific, VAD-related, and non-VAD infections. Risk of VAD-specific infections, such as driveline, pump pocket, and pump infections, remains for the duration of implantation. While adverse events are typically most common early (within 90 days of implantation), device-specific infection (primarily driveline) is a notable exception. No diminishment over time is seen, with event rates of 0.16 events per patient-year in both the early and late periods postimplantation. Management of VAD-specific infections requires aggressive treatment and chronic suppressive antimicrobial therapy is indicated when there is concern for seeding of the device. While surgical intervention/hardware removal is often necessary in prosthesis-related infections, this is not so easily accomplished with VADs. This review outlines the current state of infections in patients supported with VAD therapy and discusses future directions, including possibilities with fully implantable devices and novel approaches to treatment.
Discussing Code Status—Balancing Obligations to Respect Patient Autonomy While Avoiding Harm
This essay describes a physician’s experience of completing medical education and postgraduate clinical training in Ireland vs adjusting to residency in the US.
Interventricular-Septal Output While Supported on Left Ventricular Assist Device Therapy
The effects of left ventricular unloading on septal function in patients with left ventricular assist devices (LVADs) have not been well characterized in vivo. The purpose of this study was to evaluate the relationship between markers of septal function with echocardiography in relationship to RV dysfunction and late RV failure after LVAD implantation. A retrospective study was conducted of patients supported on centrifugal-flow LVADs implanted over a 10-year period. Echocardiographic data were collected pre-operatively and up to 2 years after implantation. Interventricular septum (IVS) measurements were taken at end-systole and end-diastole. Interventricular-septal output (ISO) was calculated using the formula: (IVSs–IVSd)×heart rate. A total of 110 patients were included. An immediate and sustained reduction in both lateral annulus systolic velocity (RVS’) and TAPSE were observed after implant (p < 0.0001). However, ISO gradually decreased over time (p < 0.0001). While ISO was not predictive of late RV failure, a decrease in ISO by 25% or greater from pre-implant to hospital discharge was associated with late RV failure (OR 4.8; 95% CI, 1.4–16.5; p = 0.012) even after adjusting for relevant clinical variables (p ≤ 0.01 for each model). RV function is known to be influenced by mechanical ventricular interdependence and we demonstrate that measurement of ISO may be a useful marker in assessing RV dysfunction and predicting RV failure in patients following LVAD implantation.