0689 Exploratory Study of the Effect of Alcohol on Home Sleep Apnea Testing Utilizing Peripheral Arterial Tone
Schnell, Aaron L, Ruoff, Chad , Tashman, Yasemin, Goswami, Umesh , Martin, Kari A. , Petersen, Ann M. , Haley, Caitlin C., Rogers, Kimberly, Lizak, Matthew, Schaal, Caroline J, Lamas, Christopher M, Lyng, Philip J., Krahn, Lois E., Ruoff, Chad M , Schnell, Aaron L, Garrett, Ashley L. , Goswami, Umesh, Petersen, Ann M, Yee, Claire

SLEEP | May 19, 2025 | Volume: 48 | Issue: Supplement_1 | Pages: A300-A300

10.1093/sleep/zsaf090.0689 Get It

Abstract Introduction A previously published case report suggested that alcohol might cause false-negative results in home sleep apnea testing (HSAT) utilizing Peripheral Arterial Tonometry (PAT). Alcohol is consumed by nearly a third of people globally. Based on this, along with rapid growth in PAT HSAT utilization, we aimed to prospectively study the interaction between alcohol consumption and PAT HSAT technology. We hypothesized that alcohol use would significantly attenuate sleep disordered breathing metrics in contrast to existing literature suggesting alcohol may exacerbate sleep apnea. Methods We planned to recruit subjects (N=100) from Mayo Clinic Arizona sleep clinic who were being evaluated for sleep-disordered breathing and elected to undergo home sleep apnea testing (WatchPAT ONE). Participants were required to report social alcohol use (no more than 1-3 drinks per day). The first and second home sleep apnea test were conducted on separate nights (night 1: without alcohol; night 2: with alcohol). Patients also completed a questionnaire, detailing their normal alcohol intake as well as intake during the respective sleep tests. Statistical analysis included paired sample t-test as well as a descriptive analysis. Results A total of 75 subjects were recruited (mean age [± SD] 56.8 ± 11.9; 90.7% male; mean BMI 29.8 ± 5.8) and 56 patients completed both sleep tests. The mean apnea hypopnea index (AHI) was not statistically different (p=0.784) between night 1 and night 2 (without alcohol: 19.6/hour ± 21.0; with alcohol: 19.3 ± 21.5, respectively). Similarly, no statistically significant difference was found in the AHI during REM and NREM sleep. Conclusion Preliminary data does not suggest a statistically significant difference in AHI without or with alcohol. While no significant change in AHI was observed, this study highlights the need for further investigation into the impact alcohol may have on PAT technology. Further analyses and data enrichment are underway. Support (if any) Mayo Foundation
Interaction of positive airway pressure mask magnets with cardiac implantable electronic devices
Ruoff, Chad M., Tashman, Yasemin S., Cheema, Kamal Preet K., Miller, Bernie W., Houser, Ryan F., Lizak, Matthew, Haley, Caitlin C., Petersen, Ann M. , Goswami, Umesh , Lyng, Philip J., Krahn, Lois E., Ruoff, Chad , Lizak, Matthew J, Ruoff, Chad M , Tashman, Yasemin, Petersen, Ann M., Goswami, Umesh, Srivathsan, Komandoor

Journal of Clinical Sleep Medicine | February 1, 2023 | Volume: 19 | Issue: 5 | Pages: 941-946

10.5664/jcsm.10478 Get It

0789 Mask Magnets May Interact with Pacemakers and Implantable Cardioverter-Defibrillators
Ruoff, Chad , Tashman, Yasemin, Miller, Bernie, Cheema, Kamal, Haley, Caitlin, Petersen, Ann, Lizak, Matthew, Goswami, Umesh , Lizak, Trevor, Krahn, Lois E., Ruoff, Chad M , Miller, Bernie, Houser, Ryan Scott , Cheema, Kamal Preet, Haley, Caitlin C., Petersen, Ann, Goswami, Umesh, Srivathsan, Komandoor

Sleep | May 31, 2022 | Volume: 45 | Issue: Supplement_1 | Pages: A342-A343

10.1093/sleep/zsac079.785 Get It

Abstract Introduction Placing a magnet over a Permanent Pacemaker (PPM) or Implanted Cardioverter-Defibrillator (ICD) may cause the device to pace asynchronously or inhibit tachyarrhythmia detection, respectively, potentially preventing delivery of electrical shocks. Manufacturers for masks used with positive airway pressure devices have started using magnets in place of more traditional headgear clips to connect the headgear to mask. Mask manufactures do not list presence of a PPM/ICD as a contraindication to use of a mask with magnet but do recommend keeping the mask some distance away from PPM/ICD. A published case series describes two patients with magnet response events captured during PPM/ICD interrogation that correlated with nightly use of CPAP. The authors were able to replicate the response by placing the mask with magnet directly over the patient’s pulse generate site. Although we advise all patients with implanted device to avoid use of masks with magnets, select patients refuse to stop using mask with magnets regardless of our policy. We, therefore, started offering these patients referral for PPM/ICD interrogation to evaluate for an interaction between mask with magnet and PPM/ICD as next best alternative. Methods We retrospectively reviewed all patients (n=10) referred for routine PPM/ICD interrogation to test whether the mask with magnet interacted with PPM/ICD when mask on face as during normal use (i.e., simulated normal use) or magnetic area of mask placed directly over the PPM/ICD (i.e., direct contact). Results Although no interaction was detected in any patient (n=10) with simulated normal use (0 %), one interaction was documented with direct contact (10 %). Conclusion Although simulated normal use of masks with magnets did not demonstrate any interactions, it is concerning that one patient (10 % of patients) demonstrated an interaction with direct contact of magnetic area of mask over the PPM/ICD. It is not uncommon for patients to remove a mask during the night while sleeping. This preliminary data along with the published case series calls for further research and increased awareness of this potential interaction for both sleep and cardiac health care providers. Support (If Any) None