Back to Authors

Boutroy, Stéphanie

https://orcid.org/0000-0003-0638-5522

Mayo Clinic

Lyon 1 Université

Citations 3

Voxel size dependency, reproducibility and sensitivity of an in vivo bone loading estimation algorithm
Christen, Patrik , Schulte, Friederike A. , Zwahlen, Alexander , Boutroy, Stéphanie , Melton, L. Joseph, Amin, Shreyasee , Khosla, Sundeep , Goldhahn, Jörg , Rietbergen, Bert van , Müller, Ralph , Khosla, Sundeep

Journal of The Royal Society Interface | January 20, 2016 | Volume: 13 | Issue: 114 | Pages: 20150991

10.1098/rsif.2015.0991 Get It

A bone loading estimation algorithm was previously developed that provides in vivo loading conditions required for in vivo bone remodelling simulations. The algorithm derives a bone's loading history from its microstructure as assessed by high-resolution (HR) computed tomography (CT). This reverse engineering approach showed accurate and realistic results based on micro-CT and HR-peripheral quantitative CT images. However, its voxel size dependency, reproducibility and sensitivity still need to be investigated, which is the purpose of this study. Voxel size dependency was tested on cadaveric distal radii with micro-CT images scanned at 25 µm and downscaled to 50, 61, 75, 82, 100, 125 and 150 µm. Reproducibility was calculated with repeated in vitro as well as in vivo HR-pQCT measurements at 82 µm. Sensitivity was defined using HR-pQCT images from women with fracture versus non-fracture, and low versus high bone volume fraction, expecting similar and different loading histories, respectively. Our results indicate that the algorithm is voxel size independent within an average (maximum) error of 8.2% (32.9%) at 61 µm, but that the dependency increases considerably at voxel sizes bigger than 82 µm. In vitro and in vivo reproducibility are up to 4.5% and 10.2%, respectively, which is comparable to other in vitro studies and slightly higher than in other in vivo studies. Subjects with different bone volume fraction were clearly distinguished but not subjects with and without fracture. This is in agreement with bone adapting to customary loading but not to fall loads. We conclude that the in vivo bone loading estimation algorithm provides reproducible, sensitive and fairly voxel size independent results at up to 82 µm, but that smaller voxel sizes would be advantageous.
Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography
Burghardt, Andrew J. , Kazakia, Galateia J. , Boutroy, Stéphanie , Patsch, Janina , Valentinitsch, Alexander , Liu, Danmei , Szabó, Éva , Bogado, César E., McKay, Heather , Shane, Elizabeth , Boyd, Steven K. , Bouxsein, Mary , Khosla, Sundeep , Pialat, Jean‐Baptiste , Engelke, Klaus , Zanchetta, María Belén , Chapurlat, Roland D , Majumdar, Sharmila , Khosla, Sundeep , Boyd, Steven K

Journal of Bone and Mineral Research | October 16, 2012 | Volume: 28 | Issue: 3 | Pages: 524-536

10.1002/jbmr.1795 Get It

Abstract High-resolution peripheral quantitative computed tomography (HR-pQCT) has recently been introduced as a clinical research tool for in vivo assessment of bone quality. The utility of this technology to address important skeletal health questions requires translation to standardized multicenter data pools. Our goal was to evaluate the feasibility of pooling data in multicenter HR-pQCT imaging trials. Reproducibility imaging experiments were performed using structure and composition-realistic phantoms constructed from cadaveric radii. Single-center precision was determined by repeat scanning over short-term (<72 hours), intermediate-term (3–5 months), and long-term intervals (28 months). Multicenter precision was determined by imaging the phantoms at nine different HR-pQCT centers. Least significant change (LSC) and root mean squared coefficient of variation (RMSCV) for each interval and across centers was calculated for bone density, geometry, microstructure, and biomechanical parameters. Single-center short-term RMSCVs were <1% for all parameters except cortical thickness (Ct.Th) (1.1%), spatial variability in cortical thickness (Ct.Th.SD) (2.6%), standard deviation of trabecular separation (Tb.Sp.SD) (1.8%), and porosity measures (6% to 8%). Intermediate-term RMSCVs were generally not statistically different from short-term values. Long-term variability was significantly greater for all density measures (0.7% to 2.0%; p < 0.05 versus short-term) and several structure measures: cortical thickness (Ct.Th) (3.4%; p < 0.01 versus short-term), cortical porosity (Ct.Po) (15.4%; p < 0.01 versus short-term), and trabecular thickness (Tb.Th) (2.2%; p < 0.01 versus short-term). Multicenter RMSCVs were also significantly higher than short-term values: 2% to 4% for density and micro–finite element analysis (µFE) measures (p < 0.0001), 2.6% to 5.3% for morphometric measures (p < 0.001), whereas Ct.Po was 16.2% (p < 0.001). In the absence of subject motion, multicenter precision errors for HR-pQCT parameters were generally less than 5%. Phantom-based multicenter precision was comparable to previously reported in in vivo single-center precision errors, although this was approximately two to five times worse than ex vivo short-term precision. The data generated from this study will contribute to the future design and validation of standardized procedures that are broadly translatable to multicenter study designs. © 2013 American Society for Bone and Mineral Research.
Microarchitectural deterioration of cortical and trabecular bone: Differing effects of denosumab and alendronate
Seeman, Ego , Delmas, Pierre D., Hanley, David A. , Sellmeyer, Deborah E. , Cheung, Angela M. , Shane, Elizabeth , Kearns, Ann E. , Thomas, Thierry , Boyd, Steven K. , Boutroy, Stéphanie , Bogado, César E., Fan, Michelle, Zanchetta, José, Majumdar, Sharmila , Libanati, Cesar R. , Boyd, Steven K , Cheung, Angela M

Journal of Bone and Mineral Research | March 10, 2010 | Volume: 25 | Issue: 8 | Pages: 1886-1894

10.1002/jbmr.81 Get It

Abstract The intensity of bone remodeling is a critical determinant of the decay of cortical and trabecular microstructure after menopause. Denosumab suppresses remodeling more than alendronate, leading to greater gains in areal bone mineral density (aBMD). These greater gains may reflect differing effects of each drug on bone microarchitecture and strength. In a phase 2 double-blind pilot study, 247 postmenopausal women were randomized to denosumab (60 mg subcutaneous 6 monthly), alendronate (70 mg oral weekly), or placebo for 12 months. All received daily calcium and vitamin D. Morphologic changes were assessed using high-resolution peripheral quantitative computed tomography (HR-pQCT) at the distal radius and distal tibia and QCT at the distal radius. Denosumab decreased serum C-telopeptide more rapidly and markedly than alendronate. In the placebo arm, total, cortical, and trabecular BMD and cortical thickness decreased (−2.1% to −0.8%) at the distal radius after 12 months. Alendronate prevented the decline (−0.6% to 2.4%, p = .051 to <.001 versus placebo), whereas denosumab prevented the decline or improved these variables (0.3% to 3.4%, p < .001 versus placebo). Changes in total and cortical BMD were greater with denosumab than with alendronate (p ≤ .024). Similar changes in these parameters were observed at the tibia. The polar moment of inertia also increased more in the denosumab than alendronate or placebo groups (p < .001). Adverse events did not differ by group. These data suggest that structural decay owing to bone remodeling and progression of bone fragility may be prevented more effectively with denosumab. © 2010 American Society for Bone and Mineral Research