Back to Authors

Pislaru, Sorin V.

https://orcid.org/0000-0002-5256-3150

Mayo Clinic

Mayo Clinic

Citations 183

Abstract 17078: Myocardial Stiffness by Intrinsic Wave Propagation Method: Comparison With End-Diastolic Pressure-Volume Relationship
Anupraiwan, Orawan, Petrescu, Ioana, Grogan, Martha , Ionescu, Filip , Pellikka, Patricia A. , Dispenzieri, Angela , Pislaru, Sorin V. , Pislaru, Cristina

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17078 Get It

Introduction: Intrinsic wave propagation is a novel approach to measure myocardial stiffness (MS) as validated in animal studies. Aims and Hypothesis: 1) To compare MS measured by the wave method with chamber stiffness (CS) derived from noninvasively estimated end-diastolic pressure-volume relationship (EDPVR) in patients; 2) To test the hypothesis that MS is superior to CS for predicting outcomes in patients with cardiac amyloidosis (CA). Methods: Prospective study in 56 patients with amyloidosis (CA: 38, noncardiac amyloidosis, NCA: 18; 90% AL-type; age 63 ± 10 yrs; ejection fraction 57 ± 11%) and 36 normal subjects (age 49 ± 13 years). Intrinsic velocity propagation of myocardial stretch (iVP), a measure of MS, was measured by ultra-high frame rate (250-465Hz) tissue Doppler imaging. Left ventricular (LV) EDPVR were reconstructed using the noninvasive single-beat method (Fig.A). Stiffness coefficients (α, β, load-independent) and CS (dP/dV) were calculated. End-diastolic pressure (EDP) was estimated from E/e’. Adverse events at follow-up (death, heart failure, stroke, significant arrhythmia) were recorded. Results: iVP was higher in CA compared to NCA and controls, indicating higher MS (Fig. B). This was confirmed by EDPVR, which were steeper and shifted leftward (Fig. A). The slope (β) of EDPVR and CS (dP/dV) were higher and LV capacitance (V 30 , volume at 30 mmHg) was lower in CA (Fig. A) and correlated with iVP (β: r = 0.59; CS dP/dV, r = 0.43; EDP, r = 0.61; all p<0.0001). Patients with higher LV thickness (r = 0.66), lower LV longitudinal strain (r = -0.57) and elevated NT-proBNP (r = 0.69) had higher iVP. At follow-up (median 2.5 years), after adjusting for relevant confounders, an iVP >2.7 m/s was strongly associated with excess events (p<0.0001; Fig. C) and was superior to measures of CS (dP/dV: p = 0.28; β >6.5: p = 0.03; Fig. D). Conclusions: Myocardial stiffness by intrinsic wave method shows similar findings to chamber stiffness by EDVPR, but is more strongly related to outcomes in patients with amyloidosis.
Abstract 17041: Increased Transvalvular Gradients Precede Clinical Diagnosis of Bioprosthetic Valve Thrombosis
Petrescu, Ioana, Connolly, Heidi M. , Egbe, Alexander C. , Ionescu, Filip , Nkomo, Vuyisile T. , Pellikka, Patricia A. , Pislaru, Sorin V.

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17041 Get It

Introduction: Bioprosthetic valve thrombosis (BPVT) is increasingly being recognized as a cause of prosthetic valve dysfunction within the first years after surgical implantation. However, in the absence of changes in clinical status, current guidelines recommend cardiac imaging only after 10 years post bioprosthetic valve implantation . Hypothesis: We hypothesized that an increase in prosthetic valve gradient is detectable months before a formal diagnosis of symptomatic BPVT. Methods: Eighty-three patients diagnosed with BPVT and treated medically at our institution between 2002 and 2017 were retrospectively identified. Transvalvular gradients recorded on TTE immediately post implantation, at time of clinical BPVT diagnosis, and within a 12-month period prior to BPVT diagnosis were available in 45 patients: 18 for the aortic position, 11 for mitral, and 16 for tricuspid. When more than one study was conducted in the 12 months’ timeframe, the latest value was used in the analysis. Data are reported as mean (95% CI). Results: For all valve positions, an increased gradient was detectable within 12 months prior to formal BPVT diagnosis: mean increase vs. baseline of 17 (10-23) mmHg, p < 0.0001 for aortic prostheses; 5 (2-8) mmHg, p = 0.004 for mitral prostheses, and 2 mm Hg (1-3) mmHg, p = 0.003 for tricuspid prostheses. The figure presents the evolution of prosthetic valve gradients (normalized to the baseline, immediately post-implantation value) in patients with aortic (left), mitral (middle), and tricuspid (right) valve . Conclusions: Elevated gradients precede formal clinical diagnosis of BPVT. Closer monitoring of transvalvular gradients may prove useful for BPVT diagnosis before patients become symptomatic. With recent evidence supporting the efficacy of anticoagulant therapy in BPVT, earlier diagnosis may lead to an increased rate of response and better clinical outcomes.
Abstract 17022: Pericardial Decompression Syndrome: Incidence in a Large Consecutive Series of Echocardiographic-Guided Pericardiocentesis Procedures
Lekhakul, Annop , Assawakawintip, Chalailak, Fenstad, Eric R. , Sinak, Lawrence J., Garvan, Kane C, Pislaru, Sorin V. , Garvan, Kane C

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17022 Get It

Introduction: Pericardial decompression syndrome (PDS) has been reported as a spectrum of cardiac decompensation following pericardiocentesis including ventricular failure, cardiogenic shock and pulmonary edema. PDS has been reported in patients undergoing drainage ≥450 mL of pericardial fluid. Hence judicious drainage of large volume effusions to avoid complication has been recommended Hypothesis: PDS complicating undergoing transthoracic echocardiography (TTE) guided pericardiocentesis is uncommen Methods: Consecutive patients undergoing TTE guided pericardiocentesis at our center from 1/2007 to 12/2016 were reviewed. Procedures were performed in a standard fashion under moderate conscious sedation with TTE determining the location of aspiration and determining adequate resolution of pericardial fluid post procedure. All fluid was removed at time of centesis regardless of the size of effusion, except for patients with severe pulmonary hypertension (n=9), who had staged removal of 100cc every 10 minutes. Post procedure, a pigtail catheter was left in the pericardial space for ongoing intermittent drainage and removed after the total net output was <50 mL/24 hours. Patients were monitored in an intermediate level care unit. All patients underwent repeat TTE at the time of catheter removal. Large volume was defined as ≥450 mL of fluid. Patients in whom pericardiocentesis was technically unsuccessful were excluded Results: Over a 10-year period a total of 1067 patients (57% male, mean age 62±16 years) underwent 1164 technically successful pericardiocentesis procedures. Of these, 561 patients had large volume (≥450 mL) aspirated (mean 750±345 mL aspirated, range 450 - 4300 mL). Patients had a pericardial catheter in place for a mean 2.9±2 days. One patient with pre-existing severe biventricular dysfunction after aspiration of 400cc developed hypotension that improved with reversal of sedation, but proceeded to have PEA arrest and die. No other patient developed clinical events of acute left or right heart failure, ventricular dysfunction, unexplained hypotension, cardiogenic shock or other clinical events that could relate to PDS Conclusions: At most one episode of PDS was observed after technically successful percutaneous pericardiocentesis in 1164 cases (561 were large volume), although whether this case was PDS is unclear. PDS appears to be very rare, and staging pericardial decompression over time may be unnecessary, other than, perhaps, in patients with severe ventricular dysfunction or severe pulmonary hypertension
Predictors of Use and Outcomes of Mechanical Valve Replacement in the United States (2008–2017)
Alkhouli, Mohamad , Nishimura, Rick A. , Pislaru, Sorin, Nishimura, Rich A, Alkhouli, Mohamad , Nishimura, Rick A , Alqahtani, Fahad , Simard, Trevor , Pislaru, Sorin V. , Schaff, Hartzell V.

Journal of the American Heart Association | June 21, 2021 | Volume: 10 | Issue: 9 | Pages: No page available

10.1161/jaha.120.019929 Get It

Background Contemporary nationwide data on the use, predictors, and outcomes of mechanical valve replacement in patients less than 70 years of age are limited. Methods and Results We identified hospitalizations for aortic valve replacement (AVR) or mitral valve replacement (MVR) in the Nationwide Inpatient Sample between January 1, 2008, and December 31, 2017. The study's end points included predictors of mechanical valve replacement and risk‐adjusted in‐hospital mortality. Among 253 100 hospitalizations for AVR, the use rate of mechanical prosthesis decreased from 45.3% in 2008 to 17.0% in 2017. Among 284 962 hospitalizations for MVR, mechanical prosthesis use decreased from 59.5% in 2008 to 29.2% in 2017 ( P for trend<0.001). In multilogistic regression analyses, female sex, prior sternotomy, prior defibrillator, and South/West geographic location were predictive of mechanical valve use. The presence of bicuspid valve was a negative predictor of mechanical AVR (odds ratio [OR], 0.68; 95% CI, 0.66–0.69; P <0.001), whereas mitral stenosis was associated with higher mechanical MVR (OR, 1.28; 95% CI, 1.22–1.33; P <0.001). Unadjusted in‐hospital mortality decreased over time with AVR but not with MVR, regardless of prosthesis choice. Using years 2008 and 2009 as a reference, risk‐adjusted mortality also decreased over time with AVR but did not decrease after MVR. Conclusions There is a substantial decline in the use of mechanical valve replacement among patients aged ≤70 years in the United States. Long‐term durability data on bioprosthetic valve replacement are needed to better define the future role of mechanical valves in this age group.
Hemolysis after transcatheter mitral valve replacement in degenerated bioprostheses, annuloplasty rings, and mitral annular calcification: Incidence, patient characteristics, and clinical outcomes
El‐Sabawi, Bassim , Eleid, Mackram F. , Rihal, Charanjit S. , Eleid, Mackram F , Guerrero, Mayra , Nkomo, Vuyisile T. , Pislaru, Sorin V. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | May 31, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ccd.29779 Get It

Gradient changes in bioprosthetic valve thrombosis: duration of anticoagulation and strategies to improve detection
Naser, Jwan A. , Petrescu, Ioana, Ionescu, Filip , Pellikka, Patricia A. , Connolly, Heidi M. , Egbe, Alexander C. , Pellikka, Patricia A , Naser, Jwan A , Nkomo, Vuyisile T. , Pislaru, Cristina , Schaff, Hartzell V. , Pislaru, Sorin V.

Open Heart | May 24, 2021 | Volume: 8 | Issue: 1 | Pages: e001608

10.1136/openhrt-2021-001608 Get It

Objective Bioprosthetic valve thrombosis (BPVT) is increasingly recognised as a major cause of prosthetic dysfunction in the first years postimplantation. How early abnormal gradients can be detected prior to diagnosis and how fast they normalise with anticoagulant therapy is unknown. We set forth to (1) evaluate patterns of increase in gradients prior to BPVT diagnosis and (2) characterise time-course of response to anticoagulation. Methods Patients treated with warfarin for BPVT (1999–2019) with clinically significant reduction of mean gradients (≥25%) were identified retrospectively. Recovery was defined as gradient decrease ≥50%, to postimplantation or to normal-range gradients per position, model and size. Time-to-BPVT (implantation—BPVT diagnosis), potential diagnostic delay (first abnormal gradient by position, model and size—BPVT diagnosis) and time-to-recovery (BPVT diagnosis—complete resolution) were recorded. Results 77 patients were identified; 32 (42%) aortic (23 surgical—12 porcine, 11 pericardial; 9 transcatheter); 24 (31%) mitral; 21 (27%) tricuspid. Median time-to-BPVT was 24, 21 and 10 months, respectively. Potential diagnostic delay was median 21 months for aortic, 4 months for mitral, but 0 for tricuspid. Recovery was significantly faster in mitral than aortic (median 2.5 vs 4.8 months, p=0.038) and tricuspid (median 5.9 months, p=0.025) positions. Porcine aortic valves responded faster than pericardial aortic valves (median 2.9 vs 20.3 months, p=0.004). Conclusion Gradients start to increase months before the clinical BPVT diagnosis. Recovery is faster in mitral and surgical aortic porcine valves; a longer warfarin trial seems indicated in tricuspid and surgical aortic pericardial valves.
Severe tricuspid bioprosthetic valve stenosis as an unusual cause of pulmonary embolism: a case report
Naser, Jwan A. , Arghami, Arman , Eleid, Mackram F. , Pislaru, Sorin V. , Sabbah, Michael S. , Arghami, Arman , Naser, Jwan A

European Heart Journal - Case Reports | May 13, 2021 | Volume: 5 | Issue: 5 | Pages: No page available

10.1093/ehjcr/ytab169 Get It

Abstract Background Bioprosthetic tricuspid valve stenosis (TS) is an uncommon and frequently under-diagnosed condition. Although the resulting right heart failure symptoms are well-known, the associated thrombogenic potential is under-recognized. Case summary A 44-year-old woman with bioprosthetic tricuspid valve (TV) replacement in 2001 was referred for urgent consultation due to acute worsening of dyspnoea and severe swelling and pain in her left arm and neck. She was diagnosed with atrial fibrillation 6 months before the presentation and was found to have right atrial (RA) thrombus with pulmonary embolism and extensive retrograde venous extension 1 month prior. Review of studies done at her local institution revealed 10 mmHg mean gradient (MG) across the bioprosthetic TV that was only reported as mild–moderate TS. Echocardiography done at our instruction confirmed suspicion of severe TS with calcified immobile leaflets. Computed tomography showed persistent RA thrombus and therefore surgical replacement of the TV was undertaken. Subsequently, patient’s dyspnoea rapidly improved. Discussion Progressive dyspnoea and symptoms of right heart failure in a patient with a history of bioprosthetic TV replacement should be investigated for prosthetic valve dysfunction. Due to its rarity, TS diagnosis can be overlooked on routine echocardiography. In our patient, despite a measured MG of 10 mmHg, the presence of critical TS was not initially recognized. As TS is associated with increased thrombogenic potential and given the rare occurrence of in situ RA thrombosis, physicians must have a high index of suspicion for TS in the appropriate clinical context.
Abstract 14414: Bioprosthetic Valve Thrombosis: Different Time to Response to Warfarin in Mitral and Aortic Valves
Egbe, Alexander C. , Petrescu, Ioana, Connolly, Heidi M. , Naser, Jwan A. , Ionescu, Filip , Nkomo, Vuyisile T. , Pislaru, Cristina , Pellikka, Patricia A. , Pislaru, Sorin V.

Circulation | May 10, 2021 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.14414 Get It

Background: Warfarin is known to be effective in the treatment of bioprosthetic valve thrombosis (BPVT). However, the time-course of response to anticoagulation has not been fully characterized. Hypothesis: We hypothesized that response to warfarin can differ depending on valve position. Methods: We retrospectively identified 45 patients with BPVT diagnosis between 2002 and 2019 that involved either the mitral (MV) or the aortic valve (AV) prostheses, all with eventual echocardiographic resolution with warfarin. BPVT involved AV in 26 (57.8%) patients and MV in 19 (42.2%). Mean gradients (MGs) were tracked starting from BPVT diagnosis until recovery, which was defined as MGs decreasing to initial post-implantation MGs, to 50% below MGs at BPVT diagnosis, or to < 20 mmHg in AV and < 5 mmHg in MV. Kaplan Meier analysis was used to compare recovery time between MV and AV. Duration is reported relative to the time of BPVT diagnosis. Results: Recovery was faster in MV than in AV patients treated with warfarin, with median time of 3.8 months in the AV and 1.8 months in the MV group, p < 0.001 (Figure 1). At 1 month follow up, 15.4% recovered in AV group and 21.1% in MV, p = 0.605. At 3 months, 38.5% recovered in the AV and 78.9% in the MV, p = 0.009. At 6 months, 57.7% of AV group recovered while 100% recovered in the MV group, p = 0.001. The longest time for recovery was 30 months in 1 AV patient. Conclusion: Recovery using warfarin tended to be faster in BPVT involving the MV compared with the AV. In our study, all patients with MV BPVT recovered by 6 months, while this only happened in half the patients with AV BPVT. This suggests that a longer duration of warfarin trial may be needed in the case of AV disease. This might also suggest that the pathogenesis may differ between the two valves.
Artificial Intelligence (AI)-Empowered Echocardiography Interpretation: A State-of-the-Art Review
Akkus, Zeynettin , Aly, Yousof H., Attia, Itzhak Z., Arruda‐Olson, Adelaide M. , Pellikka, Patricia A. , Kane, Garvan C. , Friedman, Paul A. , Oh, Jae K. , Pellikka, Patricia A , Akkus, Zeynettin , Attia, Itzhak Z., López-Jiménez, Francisco , Pislaru, Sorin V.

Journal of Clinical Medicine | March 31, 2021 | Volume: 10 | Issue: 7 | Pages: 1391

10.3390/jcm10071391 Get It

Echocardiography (Echo), a widely available, noninvasive, and portable bedside imaging tool, is the most frequently used imaging modality in assessing cardiac anatomy and function in clinical practice. On the other hand, its operator dependability introduces variability in image acquisition, measurements, and interpretation. To reduce these variabilities, there is an increasing demand for an operator- and interpreter-independent Echo system empowered with artificial intelligence (AI), which has been incorporated into diverse areas of clinical medicine. Recent advances in AI applications in computer vision have enabled us to identify conceptual and complex imaging features with the self-learning ability of AI models and efficient parallel computing power. This has resulted in vast opportunities such as providing AI models that are robust to variations with generalizability for instantaneous image quality control, aiding in the acquisition of optimal images and diagnosis of complex diseases, and improving the clinical workflow of cardiac ultrasound. In this review, we provide a state-of-the art overview of AI-empowered Echo applications in cardiology and future trends for AI-powered Echo technology that standardize measurements, aid physicians in diagnosing cardiac diseases, optimize Echo workflow in clinics, and ultimately, reduce healthcare costs.
Atrial fibrillation is associated with large beat-to-beat variability in mitral and tricuspid annulus dimensions
Naser, Jwan A. , Küçük, Hi̇lal Olgun , Ciobanu, A. , Jouni, Hayan, Oğuz, Didem , Thaden, Jeremy J. , Foley, Thomas A. , Eleid, Mackram F. , Naser, Jwan A , Ciobanu, Andrea O , Pislaru, Cristina , Pellikka, Patricia A. , Muraru, Denisa , Nkomo, Vuyisile T. , Pislaru, Sorin V.

European Heart Journal - Cardiovascular Imaging | March 11, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/ehjci/jeab033 Get It

Abstract Aims Beat-to-beat variability in cycle length is well-known in atrial fibrillation (Afib); whether this also translates to variability in annulus size remains unknown. Defining annulus maximal size in Afib is critical for accurate selection of percutaneous devices given the frequent association with mitral and tricuspid valve diseases. Methods and results Images were obtained from 170 patients undergoing 3D echocardiography [100 (50 sinus rhythm (SR) and 50 Afib) for mitral annulus (MA) and 70 (35 SR and 35 Afib) for tricuspid annulus (TA)]. Images were analysed for differences in annular dynamics with a commercially available software. Number of cardiac cycles analysed was 567 in mitral valve and 346 in tricuspid valve. Median absolute difference in maximal MA area over four to six cycles was 1.8 cm2 (range 0.5–5.2 cm2) in Afib vs. 0.8 cm2 (range 0.1–2.9 cm2) in SR, P &lt; 0.001. Maximal MA area was observed within 30–70% of the R-R interval in 81% of cardiac cycles in SR and in 73% of cycles in Afib. Median absolute difference in maximal TA area over four to six cycles was 1.4 cm2 (range 0.5–3.6 cm2) in Afib vs. 0.7 cm2 (range 0.3–1.7 cm2) in SR, P &lt; 0.001. Maximal TA area was observed within 60–100% of the R-R interval in 81% of cardiac cycles in SR, but only in 49% of cycles in Afib. Conclusion MA and TA reach maximal size within a broad time interval centred around end-systole and end-diastole, respectively, with significant beat-to-beat variability. Afib leads to a larger beat-to-beat variability in both timing of occurrence and values of annulus size than in SR.