Background: Various medial patellofemoral ligament (MPFL) reconstruction techniques have been developed to minimize risks to the physis in skeletally immature patients. Purpose: To examine outcomes of MPFL reconstruction (MPFLR) based on fixation technique in skeletally immature patients. Study Design: Systematic review; Level of evidence, 4. Methods: PubMed, Scopus, Ovid, Cochrane Library, and CINAHL databases were searched for the literature on outcomes of MPFLR in the pediatric population, utilizing various anatomic and nonanatomic techniques. Primary outcomes were postoperative redislocation rates, return-to-sports (RTS) rates, and patient-reported outcomes (PROs). Moreover, outcomes involving sequela of growth plate disturbance were collected. Results: The final analysis included 17 studies—2 using sling-based techniques, 3 using surface-based techniques, 5 using soft tissue realignments, and 7 utilizing transosseous femoral fixations. Higher rates of postoperative redislocation were found in the sling-based (14.8%) and distal soft tissue realignment using semitendinosus tenodesis (38%) techniques, while lower rates were noted with surface-based (1.3%) and transosseous (3.4%) techniques. For PROs, there were large amounts of heterogeneity among studies, but all reported postoperative improvements, with more positive PROs generally seen in anatomic reconstructions. The RTS rate was 100% for surface-based techniques, 79.4% for distal soft tissue realignments, 79.5% for soft tissue realignment techniques, and 83.2% for transosseous techniques. No negative outcomes as a sequela of growth plate disturbance were reported. Conclusion: Nonanatomic techniques—such as sling-based and distal soft tissue realignment techniques—have higher rates of redislocation and lower RTS rates in skeletally immature patients undergoing MPFLR. Surface-based and transosseous tunnel-based techniques were shown to have lower redislocation and higher RTS rates. Clinical Relevance: This review provides insight into the most appropriate surgical management of patellar instability in patients with open growth plates.
Anatomic Drivers of J-Sign Presence and Severity: If There Is a Jump, Look for a Bump
Background: Medial patellofemoral ligament reconstruction is frequently indicated for recurrent lateral patellar instability. The preoperative presence and severity of a J-sign have been associated with poorer postoperative outcomes. Purpose: To determine the underlying anatomic factors that contribute to the presence, severity, and jumping quality of the J-sign. Study Design: Cross-sectional study; Level of evidence, 3. Methods: All patients undergoing evaluation for patellar instability at a single institution between 2013 and 2023 and healthy controls without patellar instability were included. Patients with a history of knee osteotomies were excluded. The presence of a jumping J-sign and its relationship to patellofemoral measures including the Caton-Deschamps Index (CDI), trochlear dysplasia (Dejour grade), tibial tubercle–trochlear groove (TT-TG) distance, tibial tubercle lateralization, trochlear bump height, mechanical alignment, femoral anteversion, tibial torsion, trochlear medialization, patellar width, axial patellar/trochlear overlap, patellar height, trochlear height, and knee rotation angle (KRA) were measured using standardized 1.5-T magnetic resonance imaging (MRI). Univariate pairwise and multivariable analyses were performed to determine the factors associated with J-sign presence, severity, and quality. Results: Of the 130 knees with patellar instability, 89 (68.5%) demonstrated a J-sign on physical examination. In total, 44 (33.8%) patients demonstrated a 1-quadrant J-sign, 32 (24.6%) demonstrated a 2-quadrant smooth J-sign, and 13 (10.0%) demonstrated a jumping J-sign. A total of 22 control, noninstability cases were included. On multivariable analysis, increasing TT-TG distance (OR, 1.1 increase per millimeter; P = .04), external KRA (OR, 1.1 increase per degree; P = .02), and increasing CDI (OR, 1.3 increase per 0.1 increase in CDI; P = .02) were associated with J-sign presence. Increasing bump height (OR, 1.72 increase per millimeter; P = .007) and decreasing patellar width (OR, 0.89 decrease per millimeter; P = .076) were associated with a larger J-sign, when present. Increasing bump height (OR, 1.80 increase per millimeter; P = .018), increasing patellar width (OR, 1.33 increase per millimeter; P = .047), and decreasing CDI (OR, 0.009 decrease per 0.01 increase in ratio; P = .008) were associated with a jumping J-sign in comparison with a smooth 2-quadrant J-sign. A KRA of 10° (AUC, 0.70) and a cartilaginous bump height of 6.6 mm (AUC, 0.73) were thresholds associated with jumping J-sign presence. Conclusion: The presence of a J-sign is associated with MRI findings of relatively greater external tibiofemoral rotation, increased TT-TG distance, and increased patellar height, while J-sign severity and jumping quality are associated with the presence of additional underlying trochlear factors such as increased bump height. The anatomic drivers identified in this study should be further evaluated as possible factors associated with suboptimal outcomes after surgical management.
Background: Osteochondral allograft (OCA) transplantation is an important surgical technique for full-thickness chondral defects in the knee. For patients undergoing this procedure, topography matching between the donor and recipient sites is essential to limit premature wear of the OCA. Currently, there is no standardized process of donor and recipient graft matching. Purpose: To evaluate a novel topography matching technique for distal femoral condyle OCA transplantation using 3-dimensional (3D) laser scanning to create 3D-printed patient-specific instrumentation in a human cadaveric model. Study Design: Descriptive laboratory study. Methods: Human cadaveric distal femoral condyles (n = 12) underwent 3D laser scanning. An 18-mm circular osteochondral recipient defect was virtually created on the medial femoral condyle (MFC), and the position and orientation of the best topography-matched osteochondral graft from a paired donor lateral femoral condyle (LFC) were determined using an in silico analysis algorithm minimizing articular step-off distances between the edges of the graft and recipient defect. Distances between the entire surface of the OCA graft and the underneath surface of the MFC were evaluated as surface mismatch. Donor (LFC) and recipient (MFC) 3D-printed patient-specific guides were created based on 3D reconstructions of the scanned condyles. Through use of the guides, OCAs were harvested from the LFC and transplanted to the reamed recipient defect site (MFC). The post-OCA recipient condyles were laser scanned. The 360° articular step-off and cartilage topography mismatch were measured. Results: The mean cartilage step-off and graft surface mismatch for the in silico OCA transplant were 0.073 ± 0.029 mm (range, 0.005-0.113 mm) and 0.166 ± 0.039 mm (range, 0.120-0.243 mm), respectively. Comparatively, the cadaveric specimens postimplant had significantly larger step-off differences (0.173 ± 0.085 mm; range, 0.082-0.399 mm; P = .001) but equivalent graft surface topography matching (0.181 ± 0.080 mm; range, 0.087-0.396 mm; P = .678). All 12 OCA transplants had mean circumferential step-off differences less than a clinically significant cutoff of 0.5 mm. Conclusion: These findings suggest that the use of 3D-printed patient-specific guides for OCA transplantation has the ability to reliably optimize cartilage topography matching for LFC to MFC transplantation. This study demonstrated substantially lower step-off values compared with previous orthopaedic literature when also evaluating LFC to MFC transplantation. Using this novel technique in a model performing MFC to MFC transplantation has the potential to yield further enhanced results due to improved radii of curvature matching. Clinical Relevance: Topography-matched graft implantation for focal chondral defects of the knee in patients improves surface matching and has the potential to improve long-term outcomes. Efficient selection of the allograft also allows improved availability of the limited allograft sources.
Fatty Infiltration, Tear Size, and Retraction Size Are Significant Risk Factors for Retear After Arthroscopic Rotator Cuff Repair: A Systematic Review
Purpose To assess the consistency and quality of risk factor reporting for rotator cuff repair (RCR) retear and identify risk factors most frequently associated with retear. Methods A systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta‐analyses (PRISMA) guidelines. Of the initial 3,158 studies, a total of 31 met the following inclusion criteria: (1) clinical studies regarding RCR failure, (2) arthroscopic procedures involving RCR, (3) reporting of clinical outcomes, (4) publication within the past 5 years, and (5) studies investigating preoperative risk factors for retear. After full‐text review, 18 risk factors were analyzed. Results The most consistently significant risk factors were acromiohumeral distance (80%), critical shoulder angle (67%), tear size (63%), anterior‐posterior dimension (60%), fatty infiltration (FI) (58%), and retraction size (56%). FI was analyzed using different methods among studies, with 63% finding significant results and 50% of all studies performing ordinal analysis. Tear size was inconsistently analyzed quantitatively or qualitatively, with 58% of studies finding significant results and 63% of all studies performing quantitative analysis. Risk factors consistently found to be nonsignificant included age, sex, diabetes mellitus, symptom duration, hand dominance, repair technique, smoking, and body mass index. Conclusions Tear size, FI, and retraction size were found to be significant risk factors in most of the included studies evaluating rotator cuff retear. Risk factors less likely reported as predictive included repair technique, age, sex, diabetes mellitus, symptom duration, hand dominance, repair technique, smoking, and body mass index. Risk factors that require further investigation include critical shoulder angle, acromiohumeral distance, and anterior‐posterior tear dimension. Level of Evidence Level III, systematic review of Level III‐IV studies.
Biomechanical Properties and Kinematics of Medial Patellofemoral Ligament Reconstruction: A Systematic Review
Background: While the biomechanical properties of the native medial patellofemoral ligament (MPFL) have been well studied, there is no comprehensive summary of the biomechanics of MPFL reconstruction (MPFLR). An accurate understanding of the kinematic properties and functional behavior of current techniques used in MPFLR is imperative to restoring native biomechanics and improving outcomes. Purpose: To provide a comprehensive review of the biomechanical effects of variations in MPFLR, specifically to determine the effect of graft choice and reconstruction technique. Study Design: Systematic review. Methods: A systematic review was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. A total of 32 studies met inclusion criteria: (1) using ≥8 human cadaveric specimens, (2) reporting on a component of MPFLR, and (3) having multiple comparison groups. Results: Gracilis, semitendinosus, and quadriceps grafts demonstrated an ultimate load to failure (N) of 206.2, 102.8, and 190.0 to 205.0 and stiffness (N/mm) of 20.4, 8.5, and 21.4 to 33.6, respectively. Single-bundle and double-bundle techniques produced an ultimate load to failure (N) of 171 and 213 and stiffness (N/mm) of 13.9 and 17.1, respectively. Anchors placed centrally and superomedially in the patella produced the smallest degree of length changes throughout range of motion in contrast to anchors placed more proximally. Sutures, suture anchors, and transosseous tunnels all produced similar ultimate load to failure, stiffness, and elongation data. Femoral tunnel malpositioning resulted in significant increases in contact pressures, patellar translation, tilt, and graft tightening or loosening. Low tension grafts (2 N) most closely restored the patellofemoral contact pressures, translation, and tilt. Graft fixation angles variably and inconsistently altered contact pressures, and patellar translation and tilt. Conclusion: Data demonstrated that placement of the MPFLR femoral tunnel at the Schöttle point is critical to success. Femoral tunnel diameter should be ≥2 mm greater than graft diameter to limit graft advancement and overtensioning. Graft fixation, regardless of graft choice or fixation angle, is optimally performed under minimal tension with patellar fixation at the medial and superomedial patella. However, lower fixation angles may reduce graft strain, and higher fixation angles may exacerbate anisometry and length changes if femoral tunnel placement is nonanatomic.
A Systematic Review and Meta-analysis of Risk Factors for the Increased Incidence of Revision Surgery After Arthroscopic Rotator Cuff Repair
Background: Approximately 90% of patients who undergo arthroscopic rotator cuff repair (RCR) are satisfied with their pain levels and function after surgery. However, a subset of patients experience continued symptoms that warrant revision surgery. Preoperative risk factors for RCR failure requiring revision surgery have not been clearly defined. Purpose: To (1) determine the rate of RCR failure requiring revision surgery and (2) identify risk factors for revision surgery, which will help surgeons to determine patients who are at the greatest risk for RCR failure. Study Design: Systematic review and meta-analysis; Level of evidence, 4. Methods: A systematic review and meta-analysis in accordance with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were performed. The initial search resulted in 3158 titles, and 533 full-text articles were assessed for eligibility. A total of 10 studies met the following inclusion criteria: (1) human clinical studies, (2) arthroscopic RCR, (3) original clinical research, and (4) evaluation of preoperative risk factors for revision. Results: After a full-text review, a total of 16 risk factors were recorded and analyzed across 10 studies. Corticosteroid injection was the most consistent risk factor for revision surgery, reaching statistical significance in 4 of 4 studies, followed by workers’ compensation status (2/3 studies). Patients with corticosteroid injections had a pooled increased risk of revision surgery by 47% (odds ratio, 1.44 [95% CI, 1.36-1.52]). Patients with workers’ compensation had a pooled increased risk of revision surgery by 133% (odds ratio, 2.33 [95% CI, 2.09-2.60]). Age, smoking status, diabetes, and obesity were found to be risk factors in half of the analyzed studies. Conclusion: Corticosteroid injections, regardless of the frequency of injections, and workers’ compensation status were found to be significant risk factors across the literature based on qualitative analysis and pooled analysis. Surgeons should determine ideal candidates for arthroscopic RCR by accounting for corticosteroid injection history, regardless of the frequency, and insurance status of the patient.
Biomechanical Analysis of Anteroinferior Bankart Repair Anchor Types
Background: All-suture anchors and knotless anchors are increasingly used in the repair of anteroinferior labral tears in patients with shoulder instability. Optimal repair constructs may limit recurrent instability. Purpose: To perform a quantitative biomechanical comparison of 3 labral fixation devices for soft tissue Bankart lesions: knotless soft-body tensionable anchor (SB knotless), knotted soft-body anchor (SB knotted), and knotless hard-body PEEK (polyether ether ketone) interference anchor (HB knotless). Study Design: Controlled laboratory study. Methods: A total of 21 glenoid specimens were randomized into 3 groups: SB knotless, SB knotted, and HB knotless. Artificial Bankart lesions were created at the anteroinferior labrum. Anchors were placed at the 3:30, 4:30, and 5:30 clockface positions, and sutures were passed through 1 cm of tissue. Anchors were tested simultaneously as one construct by pulling capsular tissue connected to the anteroinferior quadrant. Cyclic loading (5-25 N, 100 cycles) was followed by load-to-failure testing (15 mm/min). Biomechanical testing variables were collected, and failure mechanisms were recorded per individual anchor. Results: There were no differences in baseline specimen characteristics. There was no difference in elongation during cyclic loading ( P = .40). The ultimate load to failure between SB knotless (309.7 ± 125.6 N), SB knotted (226.4 ± 34.8 N), and HB knotless (256.5 ± 90.5 N) did not significantly differ ( P = .25). Failure mechanisms differed among groups ( P = .008); mechanisms included anchor pullout (SB knotless: 33.3%; SB knotted: 23.8%; HB knotless: 28.6%), suture pull-through (SB knotless: 66.7%; SB knotted: 38.1%; HB knotless: 33.3%), and anchor fixation method failure, defined as knot failure for knotted anchors or locking mechanism failure for knotless anchors (SB knotless: 0.0%; SB knotted: 38.1%; HB knotless: 38.1%).) Conclusion: The SB knotless, SB knotted, and HB knotless labral fixation anchors studied exhibited comparable elongation during cyclic loading, stiffness, and ultimate loads to failure in a cadaveric model. However, the failure mechanisms significantly differed, as SB knotless anchors failed primarily from suture pull-through, while SB knotted and HB knotless anchors were subject to knot failure and locking mechanism failure, respectively. Clinical Relevance: These data support the benefit of SB knotless anchors for anteroinferior labral repair in limiting knot failure typically seen with knotted anchors, perhaps demonstrating that all-suture anchors may have better locking mechanism quality than their PEEK counterparts.
Factors That Affect the Magnitude of Tibial Tubercle–Trochlear Groove Distance in Patients With Patellar Instability
Background: Tibial tubercle–trochlear groove (TT-TG) distance is a risk factor for recurrent patellar dislocation and is often included in algorithmic treatment of instability. The underlying factors that determine TT-TG have yet to be clearly described in orthopaedic literature. Purpose/Hypothesis: The purpose of our study was to determine the underlying anatomic factors contributing to TT-TG distance. We hypothesized that degree of tubercle lateralization and knee rotation angle may substantially predict TT-TG. Study Design: Cross-sectional study; Level of evidence, 3. Methods: All patients evaluated for patellar instability at a single institution between 2013 and 2021 were included. Patients with previous knee osseous procedures were excluded. TT-TG and its anatomic relationship to patellofemoral measures, including dysplasia, femoral anteversion, tibial tubercle lateralization, knee rotation angle, and tibial torsion, were measured and subsequently quantified using univariate and multivariable analysis. Results: In total, 76 patients met the inclusion criteria (46 female, 30 male; mean ± SD age, 20.6 ± 8.6 years) and were evaluated. Mean TT-TG was 16.2 ± 5.4 mm. On univariate analysis, increasing knee rotation angle ( P < .01), tibial tubercle lateralization ( P = .02), and tibial torsion ( P = .01) were associated with increased TT-TG. In dysplastic cases, patients without medial hypoplasia (Dejour A or B) demonstrated significantly increased TT-TG (18.1 ± 5.4 mm) as compared with those with medial hypoplasia (Dejour C or D; TT-TG: 14.9 ± 5.2 mm; P = .02). Multivariable analysis revealed that increased knee rotation angle (+0.43-mm TT-TG per degree; P < .01) and tubercle lateralization (+0.19-mm TT-TG per percentage lateralization; P < .01) were statistically significant determinants of increased TT-TG distance. Upon accounting for these factors, tibial torsion, trochlear width, and medial hypoplasia were no longer significant components in predicting TT-TG ( P≥ .54). Of note, all patients with TT-TG ≥20 mm had tibial tubercle lateralization ≥68%, a knee rotation angle ≥5.8°, or both factors concurrently. Conclusion: TT-TG distance is most influenced by knee rotation angle and tibial tubercle lateralization.