Back to Authors

Johnson, Bruce D.

https://orcid.org/0000-0002-6283-783X

Mayo Clinic

Mayo Clinic

Citations 129

Low leptin concentration may identify heart failure patients with central sleep apnea
Čundrle, Ivan , Singh, Prachi , Johnson, Bruce D. , Olson, Lyle J. , Olson, Lyle J , Somers, Virend K. , Scott, Christopher G. , Singh, Prachi , Cundrle, Ivan

Journal of Sleep Research | June 23, 2017 | Volume: 27 | Issue: 2 | Pages: 240-243

10.1111/jsr.12574 Get It

SummaryLow leptin concentration has been shown to be associated with central sleep apnea in heart failure patients. We hypothesized that low leptin concentration predicts central sleep apnea. Consecutive ambulatory New York Heart Association (NYHA) classes I–IV heart failure patients were studied prospectively, including measurement of serum leptin, echocardiography and polysomnography. Sleep apnea was defined by type (central/mixed/obstructive) and by apnea–hypopnea index ≥5 by polysomnography. Subjects were divided into four groups by polysomnography: (1) central sleep apnea, (2) mixed apnea, (3) no apnea and (4) obstructive sleep apnea. Fifty‐six subjects were included. Eighteen subjects were diagnosed with central sleep apnea, 15 with mixed apnea, 12 with obstructive apnea and 11 with no sleep apnea. Leptin concentration was significantly lower in central sleep apnea compared to obstructive apnea (8 ± 10.7 ng mL−1 versus 19.7 ± 14.7 ng mL−1, P ˂ 0.01) or no sleep apnea (8 ± 10.7 ng mL−1 versus 17.1 ± 8.4 ng mL−1, P ˂ 0.01). Logistic regression showed leptin to be associated independently with central sleep apnea [odds ratio (OR): 0.19; 95% confidence interval (CI): 0.06–0.62; area under the curve (AUC): 0.80, P < 0.01]. For the detection of central sleep apnea, a cut‐off value for leptin concentration 5 ng mL−1 yielded a sensitivity of 50% and specificity of 89%. In conclusion, a low leptin concentration may have utility for the screening of heart failure patients for central sleep apnea.
V̇o2 kinetics associated with moderate-intensity exercise in heart failure: impact of intrathecal fentanyl inhibition of group III/IV locomotor muscle afferents
Iterson, Erik H. Van , Johnson, Bruce D. , Joyner, Michael J. , Curry, Timothy B. , Olson, Thomas P. , Van Iterson, Erik H , Joyner, Michael J

American Journal of Physiology-Heart and Circulatory Physiology | May 5, 2017 | Volume: 313 | Issue: 1 | Pages: H114-H124

10.1152/ajpheart.00014.2017 Get It

Heart failure (HF) patients demonstrate impaired pulmonary, circulatory, and nervous system responses to exercise. While HF demonstrates prolonged [time constant (τ)] pulmonary O2 uptake (V̇o2) on-kinetics, contributing to exercise intolerance, it is unknown whether abnormal V̇o2 kinetics couple with ventilatory and circulatory dysfunction secondary to impaired group III/IV afferents in HF. Because lower lumbar intrathecal fentanyl inhibits locomotor muscle afferents, resulting in improved exercise ventilation and hemodynamics, we tested these hypotheses: HF will demonstrate 1) rapid V̇o2 on-kinetics and 2) attenuated steady-state V̇o2 amplitude and O2 deficit (O2def) during exercise with fentanyl versus placebo. On separate visits (randomized), breath-by-breath V̇o2 was measured in HF (ejection fraction: 27 ± 6%, New York Heart Association class I–III) and age- and sex-matched controls (both n = 9, ages: 60 ± 6 vs. 63 ± 8 yr, P = 0.37) during cycling transitions at 65% peak workload (78 ± 24 vs. 115 ± 39 W, P < 0.01) with intrathecal fentanyl or placebo. Regardless of group or condition, optimal phase II (primary component) curve fits reflected a phase I period equal to 35 s (limb-to-lung timing) via single-exponential functions. Condition did not affect steady-state V̇o2, the phase II τ of V̇o2, or O2def within controls ( P > 0.05). Without differences in steady-state V̇o2, reduced O2def in fentanyl versus placebo within HF (13 ± 4 vs. 22 ± 15 ml/W, P = 0.04) was accounted for by a rapid phase II τ of V̇o2 in fentanyl versus placebo within HF (45 ± 11 vs. 57 ± 14 s, P = 0.04), respectively. In an integrative manner, these data demonstrate important effects of abnormal locomotor muscle afferents coupled to pulmonary and circulatory dysfunction in determining impaired exercise V̇o2 in HF. Effects of abnormal muscle afferents on impaired exercise V̇o2 and hence exercise intolerance may not be discernable by independently assessing steady-state V̇o2 in HF. NEW & NOTEWORTHY Inhibition of locomotor muscle afferents results in rapid primary-component O2 uptake (V̇o2) on-kinetics accounting for the decreased O2 deficit in heart failure (HF). This study revealed that abnormal musculoskeletal–neural afferents couple with pulmonary and circulatory dysfunction to provoke impaired exercise V̇o2 in HF. Steady-state V̇o2 cannot properly phenotype abnormal muscle afferent contributions to impaired exercise V̇o2 in HF.
The effect of aging and cardiorespiratory fitness on the lung diffusing capacity response to exercise in healthy humans
Coffman, Kirsten E. , Carlson, Alex R. , Miller, Andrew D. , Johnson, Bruce D. , Taylor, Bryan J. , Taylor, Bryan J

Journal of Applied Physiology | March 23, 2017 | Volume: 122 | Issue: 6 | Pages: 1425-1434

10.1152/japplphysiol.00694.2016 Get It

Aging is associated with deterioration in the structure and function of the pulmonary circulation. We characterized the lung diffusing capacity for carbon monoxide (DLCO), alveolar-capillary membrane conductance (DmCO), and pulmonary-capillary blood volume (Vc) response to discontinuous incremental exercise at 25, 50, 75, and 90% of peak work (Wpeak) in four groups: 1) Young [27 ± 3 yr, maximal oxygen consumption (V̇o2max): 110 ± 18% age predicted]; 2) Young Highly Fit (27 ± 3 yr, V̇o2max: 147 ± 8% age predicted); 3) Old (69 ± 5 yr, V̇o2max: 116 ± 13% age predicted); and 4) Old Highly Fit (65 ± 5 yr, V̇o2max: 162 ± 18% age predicted). At rest and at 90% Wpeak, DLCO, DmCO, and Vc were decreased with age. At 90% Wpeak, DLCO, DmCO, and Vc were greater in Old Highly Fit vs. Old adults. The slope of the DLCO-cardiac output (Q̇) relationship from rest to end exercise at 90% Wpeak was not different between Young, Young Highly Fit, Old, and Old Highly Fit (1.35 vs. 1.44 vs. 1.10 vs. 1.35 mlCO·mmHg−1·liter blood−1, P = 0.388), with no evidence of a plateau in this relationship during exercise; this was also true for DmCO-Q̇ and Vc-Q̇. V̇o2max was positively correlated with 1) DLCO, DmCO, and Vc at rest; and 2) the rest to end exercise change in DLCO, DmCO, and Vc. In conclusion, these data suggest that despite the age-associated deterioration in the structure and function of the pulmonary circulation, expansion of the pulmonary capillary network does not become limited during exercise in healthy individuals regardless of age or cardiorespiratory fitness level. NEW & NOTEWORTHY Healthy aging is a crucial area of research. This article details how differences in age and cardiorespiratory fitness level affect lung diffusing capacity, particularly during high-intensity exercise. We conclude that highly fit older adults do not experience a limit in lung diffusing capacity during high-intensity exercise. Interestingly, however, we found that highly fit older individuals demonstrate greater values of lung diffusing capacity during high-intensity exercise than their less fit age-matched counterparts.
The Influence of 17 Hours of Normobaric Hypoxia on Parallel Adjustments in Exhaled Nitric Oxide and Airway Function in Lowland Healthy Adults
Iterson, Erik H. Van , Snyder, Eric M., Johnson, Bruce D. , Van Iterson, Erik H, Van Iterson, Erik H

High Altitude Medicine & Biology | January 30, 2017 | Volume: 18 | Issue: 1 | Pages: 1-10

10.1089/ham.2016.0086 Get It

Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method
Sajgalik, Pavol , Křemen, Václav , Carlson, Alex R. , Fabián, Vratislav , Kim, Chul‐Ho , Wheatley, Courtney M. , Gerla, Václav , Schirger, John A., Olson, Thomas P. , Johnson, Bruce D. , Wheatley, Courtney, Kremen, Vaclav , Gerla, Vaclav

Journal of Applied Physiology | October 21, 2016 | Volume: 121 | Issue: 6 | Pages: 1319-1325

10.1152/japplphysiol.00981.2015 Get It

Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was −0.25 ± 1.02 l/min, Pearson’s correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson’s correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2= 0.75 at rest and RPC = 2 l/min with R2= 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.
Albuterol Improves Alveolar-Capillary Membrane Conductance in Healthy Humans
Taylor, Natalie E., Baker, Sarah E. , Olson, Thomas P. , Johnson, Bruce D. , Snyder, Eric M., Lalande, Sophie , Baker, Sarah E

Clinical Medicine Insights: Circulatory, Respiratory and Pulmonary Medicine | October 12, 2016 | Volume: 10 | Issue: No issue available | Pages: CCRPM.S30251

10.4137/ccrpm.s30251 Get It

Background Beta-2 adrenergic receptors (β 2 ARs) are located throughout the body including airway and alveolar cells. The β 2 ARs regulate lung fluid clearance through a variety of mechanisms including ion transport on alveolar cells and relaxation of the pulmonary lymphatics. We examined the effect of an inhaled β 2 -agonist (albuterol) on alveolar-capillary membrane conductance (DM) and pulmonary capillary blood volume ( V C ) in healthy humans. Methods We assessed the diffusing capacity of the lungs for carbon monoxide (DLCO) and nitric oxide (DLNO) at baseline, 30 minutes, and 60 minutes following nebulized albuterol (2.5 mg, diluted in 3 mL normal saline) in 45 healthy subjects. Seventeen subjects repeated these measures following nebulized normal saline (age = 27 ± 9 years, height = 165 ± 21 cm, weight = 68 ± 12 kg, BMI = 26 ± 9 kg/m 2 ). Cardiac output (Q), heart rate, systemic vascular resistance (SVR), blood pressure, oxygen saturation, forced expiratory volume at one-second (FEV 1 ), and forced expiratory flow at 50% of forced vital capacity (FEF 50 ) were assessed at baseline, 30 minutes, and 60 minutes following the administration of albuterol or saline. Results Albuterol resulted in a decrease in SVR, and an increase in Q, FEV 1 , and FEF 50 compared to saline controls. Albuterol also resulted in a decrease in V C at 60 minutes post albuterol. Both albuterol and normal saline resulted in no change in DLCO or DM when assessed alone, but a significant increase was observed in DM when accounting for changes in V C . Conclusion These data suggest that nebulized albuterol improves pulmonary function in healthy humans, while nebulization of both albuterol and saline results in an increase in DM/ V C .
Association of Cognitive Performance with Time at Altitude, Sleep Quality, and Acute Mountain Sickness Symptoms
Issa, Amine, Herman, Nicole , Wentz, Robert J., Taylor, Bryan J. , Summerfield, Doug C., Johnson, Bruce D. , Issa, Amine N, Herman, Nicole M, Summerfield, Douglas T. , Taylor, Bryan J

Wilderness & Environmental Medicine | July 24, 2016 | Volume: 27 | Issue: 3 | Pages: 371-378

10.1016/j.wem.2016.04.008 Get It

Objective It is well documented that cognitive performance may be altered with ascent to altitude, but the association of various cognitive performance tests with symptoms of acute mountain sickness (AMS) is not well understood. Our objective was to assess and compare cognitive performance during a high-altitude expedition using several tests and to report the association of each test with AMS, headache, and quality of sleep. Methods During an expedition to Mount Everest, 3 cognitive tests (Stroop, Trail Making, and the real-time cognitive assessment tool, an in-house developed motor accuracy test) were used along with a questionnaire to assess health and AMS. Eight team members were assessed pre-expedition, postexpedition, and at several time points during the expedition. Results There were no significant differences ( P >.05) found among scores taken at 3 time points at base camp and the postexpedition scores for all 3 tests. Changes in the Stroop test scores were significantly associated with the odds of AMS ( P <.05). The logistic regression results show that the percent change from baseline for Stroop score (β = −5.637; P = .032) and Stroop attempts (β = −5.269; P = .049) are significantly associated with the odds of meeting the criteria for AMS. Conclusions No significant changes were found in overall cognitive performance at altitude, but a significant relationship was found between symptoms of AMS and performance in certain cognitive tests. This research shows the need for more investigation of objective physiologic assessments to associate with self-perceived metrics of AMS to gauge effect on cognitive performance.
Impact of chronic systolic heart failure on lung structure-function relationships in large airways
Chase, Steven C. , Wheatley, Courtney M. , Olson, Lyle J. , Beck, Kenneth C., Wentz, Robert J., Snyder, Eric M., Taylor, Bryan J. , Johnson, Bruce D. , Taylor, Bryan J

Physiological Reports | July 14, 2016 | Volume: 4 | Issue: 13 | Pages: e12867

10.14814/phy2.12867 Get It

Correcting the dynamic response of a commercial esophageal balloon-catheter
Cross, Troy J. , Beck, Kenneth C., Johnson, Bruce D. , Cross, Troy James

Journal of Applied Physiology | July 12, 2016 | Volume: 121 | Issue: 2 | Pages: 503-511

10.1152/japplphysiol.00155.2016 Get It

It is generally recommended that an esophageal balloon-catheter possess an adequate frequency response up to 15 Hz, such that parameters of respiratory mechanics may be quantified with precision. In our experience, however, we have observed that some commercially available systems do not display an ideal frequency response (<8-10 Hz). We therefore investigated whether the poor frequency response of a commercially available esophageal catheter may be adequately compensated using two numerical techniques: 1) an exponential model correction, and 2) Wiener deconvolution. These two numerical techniques were performed on a commercial balloon-catheter interfaced with 0, 1, and 2 lengths of extension tubing (90 cm each), referred to as configurations L0, L90, and L180, respectively. The frequency response of the balloon-catheter in these configurations was assessed by empirical transfer function analysis, and its “working” range was defined as the frequency beyond which more than 5% amplitude and/or phase distortion was observed. The working frequency range of the uncorrected balloon-catheter extended up to only 10 Hz for L0, and progressively worsened with additional tubing length (L90 = 3 Hz, L180 = 2 Hz). Although both numerical methods of correction adequately enhanced the working frequency range of the balloon-catheter to beyond 25 Hz for all length configurations (L0, L90, and L180), Wiener deconvolution consistently provided more accurate corrections. Our data indicate that Wiener deconvolution provides a superior correction of the balloon-catheter's dynamic response, and is relatively more robust to extensions in catheter tube length compared with the exponential correction method.
The Impact of Averaging Window Length on the “Desaturation” Indexes Obtained Via Overnight Pulse Oximetry at High Altitude
Cross, Troy J. , Keller‐Ross, Manda L. , Issa, Amine, Wentz, Robert J., Taylor, Bryan J. , Johnson, Bruce D. , Keller-Ross, Manda, Wentz, Robert, Cross, Troy James , Taylor, Bryan J , Keller-Ross, Manda

Sleep | July 31, 2015 | Volume: 38 | Issue: 8 | Pages: 1331-1334

10.5665/sleep.4920 Get It