Back to Authors

Beck, Kenneth C.

Mayo Clinic

Mayo Clinic

Citations 21

Optimizing the calculation of alveolar capillary conductance and pulmonary capillary blood volume with carbon monoxide and nitric oxide in humans
Ceridon, Maile L., Olson, Thomas P. , Beck, Kenneth C., Johnson, Bruce D. , Bilezikian, Jordan A.

The FASEB Journal | June 21, 2021 | Volume: 23 | Issue: S1 | Pages: No page available

10.1096/fasebj.23.1_supplement.818.9 Get It

The classic method for determining alveolar‐capillary membrane conductance (D M ) and pulmonary capillary blood volume (V C ) involves measurement of lung diffusing capacity for carbon monoxide (D LCO ) at multiple inspired O 2 tensions (F I O 2 ). Recently, the technique has been simplified by simultaneously measuring D LNO (nitric oxide) to determine values at a single F I O 2 . Controversy exists over equations for calculation of θ CO (reaction rate of CO with Hgb) and the correct diffusion ratio for NO and CO (α) in the calculation of D MCO . The purpose of this study was to investigate how various published equations and ratios influence D M & V C using both the multiple and single F I O 2 methods. Eight healthy males were studied. D LCO & D LNO were measured using the rebreathe method (inspired vol. ~75% of inspiratory capacity, F I O 2 18, 35, & 55%). D M & V C were first calculated using five reported equations for θ CO . Once D M & V C were optimized based on reported predicted values, the D LNO method was compared using a range of α values. Using the multiple F I O 2 method, depending on the equation for θ CO , D M ranged from 47 to 103 ml/min/mmHg, and V C from 74 to 102 ml. For the calculation of D M & V C using the D LNO method, α ranged from 1.5 to 4.0 in order to optimize D M & V C values to the classic method. The determination of D M & V C is critically dependent on the equations used for θ CO which in turn affects the optimal ratio used to correct the D LNO method. NIH HL71478
Role of nitric oxide during hyperventilation-induced bronchoconstriction in the guinea pig
Suman, Oscar E. , Beck, Kenneth C.

Journal of Applied Physiology | December 23, 2017 | Volume: 90 | Issue: 4 | Pages: 1474-1480

10.1152/jappl.2001.90.4.1474 Get It

Airway function is largely preserved during exercise or isocapnic hyperventilation in humans and guinea pigs despite likely changes in airway milieu during hyperpnea. It is only on cessation of a hyperpneic challenge that airway function deteriorates significantly. We tested the hypothesis that nitric oxide, a known bronchodilator that is produced in the lungs and bronchi, might be responsible for the relative bronchodilation observed during hyperventilation (HV) in guinea pigs. Three groups of anesthetized guinea pigs were given saline and three groups given 50 mg/kg NG-monomethyl-l-arginine (l-NMMA), a potent nitric oxide synthase inhibitor. Three isocapnic ventilation groups included normal ventilation [40 breaths/min, 6 ml/kg tidal volume (Vt)], increased respiratory rate only (150 breaths/min, 6 ml/kg Vt), and increased respiratory rate and increased volume (100 breaths/min, 8 ml/kg Vt). l-NMMA reduced expired nitric oxide in all groups. Expired nitric oxide was slightly but significantly increased by HV in the saline groups. However, inhibition of nitric oxide production had no significant effect on rate of rise of respiratory system resistance (Rrs) during HV or on the larger rise in Rrs seen 6 min after HV. We conclude that nitric oxide synthase inhibition has no effect on changes in Rrs, either during or after HV in guinea pigs.
Airway function after cyclooxygenase inhibition during hyperpnea-induced bronchoconstriction in guinea pigs
Suman, Oscar E. , Morrow, Jason D., OʼMalley, K., Beck, Kenneth C.

Journal of Applied Physiology | December 23, 2017 | Volume: 89 | Issue: 5 | Pages: 1971-1978

10.1152/jappl.2000.89.5.1971 Get It

Airway function deteriorates significantly on cessation of exercise or isocapnic hyperventilation challenges but is largely preserved during the challenge in humans and guinea pigs. PGE2, an endogenous bronchodilator, might be responsible for the preservation of lung function during hyperventilation (HV). We hypothesized that PGE2might have a protective effect during HV, partially explaining the minimal changes in respiratory system resistance (Rrs) usually seen during HV in humans and guinea pigs. Therefore, changes in Rrs were measured during and after HV in anesthetized, mechanically ventilated guinea pigs treated with flurbiprofen (FBN) or placebo. With HV, there was an initial bronchodilation that was unaffected by FBN. Rrs then increased with time during HV, an effect that was blocked by FBN. After HV, Rrs increased further in all groups, but the increase in Rrs was less in the FBN-treated groups. FBN treatment reduced the PGE2concentration slightly in lung lavage fluid compared with placebo. We found no enhancement or refractoriness of the Rrs response to repeat bouts of HV and no effect of FBN treatment on the response of Rrs to repeat HV. These results suggest that a constrictor PG is released during and possibly after HV and that the post-HV increase in Rrs is the sum of effects of the PG released during HV and a second constrictor mechanism operating after HV. We found no evidence for bronchodilator PG during or after HV in the guinea pig.
Cardiac output during exercise by the open circuit acetylene washin method: comparison with direct Fick
Johnson, Bruce D., Beck, Kenneth C., Dietz, Niki M., Proctor, David N. , Miller, Jordan D. , Joyner, Michael J.

Journal of Applied Physiology | December 23, 2017 | Volume: 88 | Issue: 5 | Pages: 1650-1658

10.1152/jappl.2000.88.5.1650 Get It

An open-circuit (OpCirc) acetylene uptake cardiac output (Q˙t) method was modified for use during exercise. Two computational techniques were used. OpCirc1 was based on the integrated uptake vs. end-tidal change in acetylene, and OpCirc2 was based on an iterative finite difference modeling method. Six subjects [28–44 yr, peak oxygen consumption (V˙o2) = 120% predicted] performed cycle ergometry exercise to compareQ˙t using OpCirc and direct Fick methods. An incremental protocol was repeated twice, separated by a 10-min rest, and subsequently subjects exercised at 85–90% of their peak work rate. Coefficient of variation of the OpCirc methods and Fick were highest at rest (OpCirc1, 7%, OpCirc2, 12%, Fick, 10%) but were lower at moderate to high exercise intensities (OpCirc1, 3%, OpCirc2, 3%, Fick, 5%). OpCirc1 and OpCirc2 Q˙t correlated highly with Fick Q˙t( R2= 0.90 and 0.89, respectively). There were minimal differences between OpCirc1 and OpCirc2 compared with Fick up to moderate-intensity exercise (<70% peakV˙o2); however, both techniques tended to underestimate Fick at >70% peakV˙o2. These differences became significant for OpCirc1 only. Part of the differences between Fick and OpCirc methods at the higher exercise intensities are likely related to inhomogeneities in ventilation and perfusion matching ( R2= 0.36 for Fick − OpCirc1 vs. alveolar-to-arterial oxygen tension difference). In conclusion, both OpCirc methods provided reproducible, reliable measurements ofQ˙t during mild to moderate exercise. However, only OpCirc2 appeared to approximate FickQ˙t at the higher work intensities.
Variance of ventilation during exercise
Beck, Kenneth C., Wilson, Theodore A.

Journal of Applied Physiology | December 22, 2017 | Volume: 90 | Issue: 6 | Pages: 2151-2156

10.1152/jappl.2001.90.6.2151 Get It

Expired gas concentrations were measured during a multibreath washin of He in one female and seven male subjects at rest (seated) and during cycle exercise at work rates of 70–210 W. In a computational model, the ventilation distribution was represented as a log-normal distribution with standard deviation (ςV˙); values of ςV˙ were obtained by fitting the output of the model to the data. At rest, ςV˙ was 0.89 ± 0.18; during exercise, ςV˙ was 0.60 ± 0.13, independent of the level of exercise. These values for the width of the functional ventilation distribution at the scale of the acinus are approximately two times larger than those obtained from anatomic measurements in animals at a scale of 1 cm3. The values for ςV˙, together with data from the literature on the width of the functional ventilation-perfusion distribution, show that ventilation and perfusion are highly correlated at rest, in agreement with anatomic data. The structural sources of nonuniform ventilation and perfusion and of the correlation between them are unknown.
Influence of age and gender on cardiac output-V˙o2relationships during submaximal cycle ergometry
Beck, Kenneth C., Shen, Peter H., Eickhoff, Tamara J., Halliwill, John R. , Proctor, David N. , Joyner, Michael J.

Journal of Applied Physiology | December 22, 2017 | Volume: 84 | Issue: 2 | Pages: 599-605

10.1152/jappl.1998.84.2.599 Get It

Proctor, David N., Kenneth C. Beck, Peter H. Shen, Tamara J. Eickhoff, John R. Halliwill, and Michael J. Joyner. Influence of age and gender on cardiac output-V˙o2relationships during submaximal cycle ergometry. J. Appl. Physiol. 84(2): 599–605, 1998.—It is presently unclear how gender, aging, and physical activity status interact to determine the magnitude of the rise in cardiac output (Q˙c) during dynamic exercise. To clarify this issue, the present study examined theQ˙c-O2uptake (V˙o2) relationship during graded leg cycle ergometry in 30 chronically endurance-trained subjects from four groups ( n = 6–8/group): younger men (20–30 yr), older men (56–72 yr), younger women (24–31 yr), and older women (51–72 yr). Q˙c (acetylene rebreathing), stroke volume (Q˙c/heart rate), and whole bodyV˙o2were measured at rest and during submaximal exercise intensities (40, 70, and ∼90% of peakV˙o2). Baseline resting levels of Q˙c were 0.6–1.2 l/min less in the older groups. However, the slopes of theQ˙c-V˙o2relationship across submaximal levels of cycling were similar among all four groups (5.4–5.9 l/l). The absolute Q˙c associated with a given V˙o2(1.0–2.0 l/min) was also similar among groups. Resting and exercise stroke volumes (ml/beat) were lower in women than in men but did not differ among age groups. However, older men and women showed a reduced ability, relative to their younger counterparts, to maintain stroke volume at exercise intensities above 70% of peakV˙o2. This latter effect was most prominent in the oldest women. These findings suggest that neither age nor gender has a significant impact on theQ˙c-V˙o2relationships during submaximal cycle ergometry among chronically endurance-trained individuals.
Evaluation of pulmonary resistance and maximal expiratory flow measurements during exercise in humans
Beck, Kenneth C., Hyatt, Robert E., Mpougas, Panagiotis, Scanlon, Paul D.

Journal of Applied Physiology | December 22, 2017 | Volume: 86 | Issue: 4 | Pages: 1388-1395

10.1152/jappl.1999.86.4.1388 Get It

To evaluate methods used to document changes in airway function during and after exercise, we studied nine subjects with exercise-induced asthma and five subjects without asthma. Airway function was assessed from measurements of pulmonary resistance (Rl) and forced expiratory vital capacity maneuvers. In the asthmatic subjects, forced expiratory volume in 1 s (FEV1) fell 24 ± 14% and Rl increased 176 ± 153% after exercise, whereas normal subjects experienced no change in airway function (Rl−3 ± 8% and FEV1−4 ± 5%). During exercise, there was a tendency for FEV1 to increase in the asthmatic subjects but not in the normal subjects. Rl, however, showed a slight increase during exercise in both groups. Changes in lung volumes encountered during exercise were small and had no consistent effect on Rl. The small increases in Rl during exercise could be explained by the nonlinearity of the pressure-flow relationship and the increased tidal breathing flows associated with exercise. In the asthmatic subjects, a deep inspiration (DI) caused a small, significant, transient decrease in Rl 15 min after exercise. There was no change in Rl in response to DI during exercise in either asthmatic or nonasthmatic subjects. When percent changes in Rl and FEV1 during and after exercise were compared, there was close agreement between the two measurements of change in airway function. In the groups of normal and mildly asthmatic subjects, we conclude that changes in lung volume and DIs had no influence on Rl during exercise. Increases in tidal breathing flows had only minor influence on measurements of Rl during exercise. Furthermore, changes in Rl and in FEV1 produce equivalent indexes of the variations in airway function during and after exercise.
Regulation of ventilatory capacity during exercise in asthmatics
Johnson, B. D., Scanlon, Paul D., Beck, Kenneth C.

Journal of Applied Physiology | December 22, 2017 | Volume: 79 | Issue: 3 | Pages: 892-901

10.1152/jappl.1995.79.3.892 Get It

In asthmatic and control subjects, we examined the changes in ventilatory capacity (VECap), end-expiratory lung volume (EELV), and degree of flow limitation during three types of exercise: 1) incremental, 2) constant load (50% of maximal exercise capacity; 36 min), and 3) interval (alternating between 60 and 40% of maximal exercise capacity; 6-min workloads for 36 min). The VECap and degree of flow limitation at rest and during the various stages of exercise were estimated by aligning the tidal breathing flow-volume (F-V) loops within the maximal expiratory F-V (MEFV) envelope using the measured EELV. In contrast to more usual estimates of VECap (i.e., maximal voluntary ventilation and forced expiratory volume in 1 s x 40), the calculated VECap depended on the existing bronchomotor tone, the lung volume at which the subjects breathed (i.e., EELV), and the tidal volume. During interval and constant-load exercise, asthmatic subjects experienced reduced ventilatory reserve, higher degrees of flow limitation, and had higher EELVs compared with nonasthmatic subjects. During interval exercise, the VECap of the asthmatic subjects increased and decreased with variations in minute ventilation, due in part to alterations in their MEFV curve as exercise intensity varied between 60 and 49% of maximal capacity. In conclusion, asthmatic subjects have a more variable VECap and reduced ventilatory reserve during exercise compared with nonasthmatic subjects. The variations in VECap are due in part to a more labile MEFV curve secondary to changes in bronchomotor tone. Asthmatics defend VECap and minimize flow limitation by increasing EELV.
Airway obstruction during exercise and isocapnic hyperventilation in asthmatic subjects
Suman, Oscar E. , Beck, Kenneth C., Babcock, Mark A., Pegelow, David F., Reddan, W. G.

Journal of Applied Physiology | December 22, 2017 | Volume: 87 | Issue: 3 | Pages: 1107-1113

10.1152/jappl.1999.87.3.1107 Get It

We compared pulmonary mechanics measured during long-term exercise (LTX = 20 min) with long-term isocapnic hyperventilation (LTIH = 20 min) in the same asthmatic individuals ( n = 6). Peak expiratory flow (PEF) and forced expiratory volume in 1 s (FEV1) decreased during LTX (−19.7 and −22.0%, respectively) and during LTIH (−6.66 and 10.9%, respectively). In contrast, inspiratory pulmonary resistance (Rl I) was elevated during LTX (57.6%) but not during LTIH (9.62%). As expected, airway function deteriorated post-LTX and post-LTIH (FEV1 = −30.2 and −21.2%; Rl I = 111.8 and 86.5%, respectively). We conclude that the degree of airway obstruction observed during LTX is of a greater magnitude than that observed during LTIH. Both modes of hyperpnea induced similar levels of airway obstruction in the posthyperpnea period. However, the greater airway obstruction during LTX suggests that a different process may be responsible for the changes in airway function during and after the two modes of hyperpnea. This finding raises questions about the equivalency of LTIH and LTX in the study of airway function during exercise-induced asthma.
Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise
Beck, Kenneth C., Proctor, David N.

Journal of Applied Physiology | December 22, 2017 | Volume: 81 | Issue: 6 | Pages: 2495-2499

10.1152/jappl.1996.81.6.2495 Get It

Proctor, David N., and Kenneth C. Beck. Delay time adjustments to minimize errors in breath-by-breath measurement ofV˙o2during exercise. J. Appl. Physiol. 81(6): 2495–2499, 1996.—If the delay time between gas concentration and flow signals is not adequately corrected during breath-by-breath analysis of expired gas, an error in calculation of oxygen consumption (V˙o2) will result. To examine the frequency and delay time dependences of errors inV˙o2measurement, six healthy men exercised at 100, 200, and 250 W on a cycle ergometer while breath-by-breath assessment ofV˙o2was made simultaneously with collection of expired air. Subjects breathed first at normal rates (15–30 breaths/min) and then at 70 breaths/min. Each subject performed each level of exercise twice by using erroneous values for the delay time between gas concentration and flow signals. At normal breathing frequencies, errors inV˙o2measurement were ±10% over the full range of delay times used, and the errors were not tightly correlated with variations in delay times from optimum. However, at 70 breaths/min, errors approached ±30% as the variations in delay times deviated ±0.1 s from the optimal, and the errors were highly correlated with the variations in delay times. We conclude that there is greater potential for errors inV˙o2measurement with incorrect delay time at higher breathing frequencies. These findings suggest that the optimal delay time for breath-by-breath systems should be adjusted by using high breathing frequencies.