ObjectivesCrohn disease (CD) is a chronic inflammation in the digestive tract that affects millions of Americans. Bowel vascularity has important diagnostic information because inflammation is associated with blood flow changes. We recently developed an ultrasensitive ultrasound microvessel imaging (UMI) technique with high vessel sensitivity. This study aimed to evaluate the feasibility of UMI to assist CD detection and staging.MethodsUltrasound microvessel imaging was performed on 76 bowel wall segments from 48 symptomatic patients with CD. Clinically indicated computed tomographic/magnetic resonance enterography was used as the reference standard. The vessel‐length ratio (VLR, the number of vessel pixels in the bowel wall segment normalized to the segment length) was derived in both conventional color flow imaging (CFI) and UMI to quantitatively stage disease activity. Receiver operating characteristic curves were then analyzed between different disease groups.ResultsThe VLR‐CFI and VLR‐UMI detected similar correlations between vascularization and disease activity: severe inflammation had a higher VLR than normal/mildly inflamed bowels (P < .05). No significant difference was found between quiescent and mild CD due to the small sample size. The VLR‐CFI had more difficulties in distinguishing quiescent versus mild CD compared to the VLR‐UMI. After combining the VLR‐UMI with thickness, in the receiver operating characteristic curve analysis, the areas under the curves (AUCs) improved to AUC1 = 0.996 for active versus quiescent CD, AUC2 = 0.978 for quiescent versus mild CD, and AUC3 = 0.931 for mild versus severe CD, respectively, compared to those using thickness alone (AUC1 = 0.968; P = .04; AUC2 = 0.919; P = .16; AUC3 = 0.857; P = .01).ConclusionsUltrasound microvessel imaging offers a safe and cost‐effective tool for CD diagnosis and staging, which may potentially assist disease activity classification and therapy efficacy evaluation.
Liver Stiffness Measured with Two-dimensional Shear-Wave Elastography Is Predictive of Liver-related Events in Patients with Chronic Liver Disease Due to Hepatis B Viral Infection
Abstract Rationale: Epstein–Barr virus (EBV)-related lymphoepithelioma-like cholangiocarcinoma (LELCC) is an extremely rare primary liver tumor with nonspecific clinical manifestations. The clinicopathological features of EBV-associated LELCC have been reported in a few cases. But reports of the tumor's imaging characteristics, particularly ultrasonographic findings, are very rare. Patient concerns: The first patient was a 64-year-old man with left upper quadrant pain and no nausea and dizziness for about 3 months. The second patient was a 40-year-old man, had an incidental finding of a hepatic tumor in a routine health checkup at a local hospital. Diagnoses: In the first patient, the abdominal ultrasound demonstrated a slightly heterogeneous hypoechoic nodule in segment 3 of the liver. The nodule was about 2.0 cm × 1.7 cm in size, with a clear margin and regular shape. Color Doppler flow imaging (CDFI) revealed no blood flow signals in this nodule. According to the clinical information and imaging features, it was difficult to determine the diagnosis of the nodule. In the second patient, gray-scale ultrasound revealed a slightly heterogeneous hypoechoic mass measuring 3.5 cm × 2.5 cm with well-defined margin and regular shape at the superior segment of the left hepatic lateral lobe. There was a blurrily hypoechoic halo around the mass. In contrast-enhanced ultrasound (CEUS), the mass was homogeneous hyperenhancement in the arterial phase. In the portal phase and late phase, the center enhancement of the mass washed out gradually, presenting hypoenhancement, Therefore, the tumor was diagnosed as malignancy. Intervention: Finally, a laparoscopic left hepatic lateral lobectomy was performed in the first patient. The second patient underwent a left hepatectomy with cholecystectomy. Outcomes: The first patient has been alive without recurrence or distant metastases for 11 months since the surgery. The second patient received routine follow-up after surgery. Until now, he has been tumor-free for 32 months. Lessons: We mainly focus on the ultrasound characteristics of EBV-associated LELCC, especially its enhancement patterns on CEUS, which may provide valuable information for diagnosis of the LELCC. When a liver tumor with typical CEUS patterns of malignancy is found in middle-aged adults with EBV positive, the possibility of EBV-related LELCC should be considered.
Rapid conjugation of nanoparticles, proteins and siRNAs to microbubbles by strain-promoted click chemistry for ultrasound imaging and drug delivery
Strain-promoted alkyne–azide cycloaddition (SPAAC) click chemistry was applied for the rapid conjugation of nanoparticles, proteins, and siRNA-micelles to ultrasound microbubbles.
Three-dimensional shear wave elastography for differentiation of breast lesions: An initial study with quantitative analysis using three orthogonal planes
Ultrafast plane wave imaging enables acquisition and accumulation of a large number of Doppler ensembles in a short period of time, which substantially boosts ultrasound Doppler sensitivity by at least an order of magnitude. As a key component, spatiotemporal clutter filtering based on singular value decomposition (SVD) has recently demonstrated superior performance in tissue clutter suppression and microvessel signal extraction over conventional high-pass-filter-based clutter filtering techniques. This presentation introduces several novel SVD clutter filter techniques from our recent work, focusing on addressing the technical challenges (complex tissue motion, high computational cost, and noise) of SVD clutter filter during clinical translations of the ultrafast microvessel imaging technology for human imaging. We present a block-wise adaptive SVD filter method that can robustly threshold singular values on a local level, a real-time feasible SVD clutter filtering method based on partial SVD and randomized spatial downsampling, and a noise equalization and suppression method that can significantly improve microvessel imaging quality at a low cost. In vivo performance of these methods will be demonstrated in different organs.
Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography
AbstractBecause of the rapidly growing use of ultrasound shear wave elastography (SWE) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists’ tasks: (a) acceptance testing (AT) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT, ten GE LOGIQ E9 XDclear 2.0 scanners with ten C1‐6‐D and ten 9L‐D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT. A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared — a Supersonic Aixplorer scanner with a SL10‐2 and a SL15‐4 transducer, and an abovementioned GE scanner with 9L‐D transducer. Two stepped cylinders with diameters of 4.05–10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in‐house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL15‐4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE‐related tasks in the clinical environment.
ELASTICITY MEASUREMENTS BY SHEAR WAVE ELASTOGRAPHY: COMPARISON AND SELECTION OF SHEAR WAVE, RAYLEIGH WAVE AND LAMB WAVE THEORY
Shear wave elastography (SWE) is a powerful method for the diagnosis of tissue disorders or degeneration based on tissue elasticity. In SWE application, it was recognized that the wave speed depends not only on the tissue elasticity but also on the structural shape, leading to different theoretical models. For liver, skin and myocardium, the appropriate theoretical model is known to be shear wave, Rayleigh wave and Lamb wave theory, respectively. Therefore, appropriate theoretical model should be adopted for the proper application of SWE. In this study, we verify these theoretical models in gelatin samples of different thicknesses, using experimental and numerical SWE tests. The results indicate that the wave speed was influenced by the ratio of the wavelength and sample thickness and the measurement region. Based on these results, the selection of theoretical model could be divided into three cases, and the appropriate theoretical model can be selected accordingly.