Abstract Introduction The optimal irrigation solution with inflatable penile prosthesis (IPP) remains controversial. Objective We sought to determine the impact of the type of fluid used for dipping and irrigation (D&I) on the risk of IPP infections. Methods This is a retrospective, consecutive cohort study that includes individuals who underwent initial Coloplast IPP insertion or revision between January 2021 and May 2024. Cases done from January 2021 to August 2022 (20 months) underwent Rifampin/Gentamycin for dipping and Vancomycin/Gentamycin for irrigation (Group 1), whereas those from October 2022 to May 2024 (20 months) utilized 0.05% chlorhexidine gluconate for both D & I (Group 2). Surgeon, operative time, age, diabetes mellitus (DM), perioperative level of HbA1C, history of acute urinary retention (AUR), positive urine culture, and oral antibiotic (AB) regimen at discharge were obtained. The rate of infection between the two study groups and the association of risk factors with developing infection were explored by t-test and chi-square analysis for continuous and discrete variables, respectively. P-value less than 0.05 was considered statistically significant. Results In comparison of two study groups, infection rate was significantly higher in group 2 at 2.5% (8/314) than group 1 which did not have any infection (0/280) (P = 0.008). There was no significant association between the study group and operative time (P = 0.45), DM (P = 0.29), HbA1C level (P = 0.20) and AUR (P = 0.87) or surgeon (Table 1). Notably, two clinical infections were from non-virulent organisms (Streptococcus Constellatus & Staphylococcus Lugdunensis). Two of three patients undergoing malleable salvage failed. Since no infection was observed in group1, infection risk predictors were only analyzed in group 2. The patients in group 2 were stratified based on their diabetes mellitus (DM) status, and analyses were conducted to investigate the effect of a positive DM history on the risk of infection. The results indicated that having DM significantly increased the risk of infection, with 75% (6/8) of patients with DM developing an infection compared to 26% (78/306) of those without DM (P = 0.006) (Table 2). Notably, three of eight infections occurred in patients discharged on Augmentin or cefdinir secondary to drug interaction warning (our typical post op prophylaxis is Bactrim or ciprofloxacin). Conclusions Type of antiseptic fluid for D&I and DM were associated with IPP infection following surgery in our patient cohort. Disclosure No.
232 Patient Perception of Penile Size and Device after Penile Implant Revision for Mechanical Failure
ABSTRACT Introduction IPP revision after implant malfunction yields rare insight into patient preference and perception of penile implant variations in brand and size. Objective To assess patients’ perception of their penile implant after IPP revision. Methods Retrospective review of all patients undergoing revision surgery for purely mechanical malfunction (fluid leak) at our institution since 2017. Patients with greater than 6 months follow-up after revision were contacted to comment on changes in penile size and device preference. Patients were asked 1. “Did you notice any change in penile length or girth after your last surgery, explain, and 2. “Please describe your preference (if any) of implant and why”. We utilize the Coloplast Titan with “classic” (genesis) pump in most cases, with AMS Cx cylinders being used in cases with attenuated corpora (aneurysm). Results 21 patients were identified that met criteria with an average age of 70. 15/21 were successfully contacted. 9 Coloplast, 2 Mentor, and 12 AMS devices (Cx =7, LGX =4, Ultrex =1) were revised. Device brand used to replace the broken IPP was n= 19 for Coloplast and n=3 for AMS (Cx =2, Lgx =1). Mean and median time to revision was 9 years overall (2-26) and was similar between Coloplast and AMS. Fluid leak location showed no discernable pattern. Total average implant length increased 2.2 cm from 20.6 cm to 22.8 cm. 8/10 patients were reached that had had both AMS and Coloplast devices (all AMS initially). 12 patients stayed within the manufacturer. Despite change in implanted length, most patients did not discern a definitive change in penile length unless cylinders increased by > 3 cm (perhaps reflecting under-sizing of initial implant). All patients correctly described improvement or no change in penile girth when compared to actual cylinder sizes. Patients preferred Coloplast (6 – girth/erection quality/pump), AMS (1 pump/flaccidity) and undecided (1). Several patients felt consistently cycling the device after revision led to relative length improvement and ease of use. Conclusions Our small cohort of IPP revision patients for mechanical failure reveals that revision often requires longer cylinders but this is often imperceptible to the patient. Increased cylinder girth was a key factor in driving device preference. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Senior author consultant for Coloplast