Back to Authors

Murray, David

https://orcid.org/0000-0003-1720-335X

Mayo Clinic

Mayo Clinic

Citations 115

Comprehensive Assessment of M-Proteins Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry
Mills, John R. , Kohlhagen, Mindy , Dasari, Surendra , Vanderboom, Patrick M. , Kyle, Robert A. , Katzmann, Jerry A., Barnidge, David R. , Dispenzieri, Angela , Murray, David , Willrich, Maria Alice V. , Dispenzieri, Angela

Clinical Chemistry | August 18, 2016 | Volume: 62 | Issue: 10 | Pages: 1334-1344

10.1373/clinchem.2015.253740 Get It

Abstract BACKGROUND Electrophoretic separation of serum and urine proteins has played a central role in diagnosing and monitoring plasma cell disorders. Despite limitations in resolution and analytical sensitivity, plus the necessity for adjunct methods, protein gel electrophoresis and immunofixation electrophoresis (IFE) remain front-line tests. METHODS We developed a MALDI mass spectrometry–based assay that was simple to perform, automatable, analytically sensitive, and applicable to analyzing the wide variety of monoclonal proteins (M-proteins) encountered clinically. This assay, called MASS-FIX, used the unique molecular mass signatures of the different Ig isotypes in combination with nanobody immunoenrichment to generate information-rich mass spectra from which M-proteins could be identified, isotyped, and quantified. The performance of MASS-FIX was compared to current gel-based electrophoresis assays. RESULTS MASS-FIX detected all M-proteins that were detectable by urine or serum protein electrophoresis. In serial dilution studies, MASS-FIX was more analytically sensitive than IFE. For patient samples, MASS-FIX provided the same primary isotype information for 98% of serum M-proteins (n = 152) and 95% of urine M-proteins (n = 55). MASS-FIX accurately quantified M-protein to <1 g/dL, with reduced bias as compared to protein electrophoresis. Intraassay and interassay CVs were <20% across all samples having M-protein concentrations >0.045 g/dL, with the ability to detect M-proteins <0.01 g/dL. In addition, MASS-FIX could simultaneously measure κ:λ light chain ratios for IgG, IgA, and IgM. Retrospective serial monitoring of patients with myeloma posttreatment demonstrated that MASS-FIX provided equivalent quantitative information to either protein electrophoresis or the Hevylite™ assay. CONCLUSIONS MASS-FIX can advance how plasma cell disorders are screened, diagnosed, and monitored.
Screening Method for M-Proteins in Serum Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry
Kohlhagen, Mindy , Barnidge, David R. , Mills, John R. , Stoner, Joshua, Gurtner, Kari M., Liptac, Andrea M, Lofgren, Denise I, Vanderboom, Patrick M. , Dispenzieri, Angela , Katzmann, Jerry A., Snyder, Melissa R, Murray, David , Willrich, Maria Alice V. , Snyder, Melissa R, Dispenzieri, Angela

Clinical Chemistry | August 12, 2016 | Volume: 62 | Issue: 10 | Pages: 1345-1352

10.1373/clinchem.2015.253781 Get It

Abstract BACKGROUND Current recommendations for screening for monoclonal gammopathies include serum protein electrophoresis (PEL), imunofixation electrophoresis (IFE), and free light chain (FLC) ratios to identify or rule out an M-protein. The aim of this study was to examine the feasibility of an assay based on immunoenrichment and MALDI-TOF-MS (MASS-SCREEN) to qualitatively screen for M-proteins. METHODS Serum from 556 patients previously screened for M-proteins by PEL and IFE were immunopurified using a κ/λ-specific nanobody bead mixture. Following purification, light chains (LC) were released from their heavy chains by reduction. MALDI-TOF analysis was performed and the mass-to-charge LC distributions were visually examined for the presence of an M-protein by both unblinded and blinded analysts. RESULTS In unblinded analysis, MASS-SCREEN detected 100% of the PEL-positive samples with an analytical sensitivity and specificity of 96% and 81% using IFE positivity as the standard. In a blinded analysis using 6 different laboratory personnel, consensus was reached in 92% of the samples. Overall analytical sensitivity and specificity were reduced to 92% and 80%, respectively. FLC ratios were found to be abnormal in 28% of MASS-SCREEN–negative samples, suggesting FLC measurements need to be considered in screening. CONCLUSIONS MASS-SCREEN could replace PEL in a panel that would include FLC measurements. Further studies and method development should be performed to validate the clinical sensitivity and specificity and to determine if this panel will suffice as a general screen for monoclonal proteins.
Using Mass Spectrometry to Quantify Rituximab and Perform Individualized Immunoglobulin Phenotyping in ANCA-Associated Vasculitis
Mills, John R. , Dasari, Surendra , Ladwig, Paula M. , Hummel, Amber M., Cheu, Melissa , Murray, David , Snyder, Melissa R., Hoffman, Gary S., Kallenberg, Cees G. M., Langford, Carol A. , Seo, Philip , Clair, E. William St. , Stone, John H., Barnidge, David R. , Snyder, M , Cornec, Divi, Murray, David L., Willrich, Maria A, Cornec, Divi , Willrich, Maria Alice V. , Snyder, Melissa R., Merkel, Peter A. , Monach, Paul A. , Spiera, Robert , Specks, Ulrich , Snyder, Michael

Analytical Chemistry | May 26, 2016 | Volume: 88 | Issue: 12 | Pages: 6317-6325

10.1021/acs.analchem.6b00544 Get It

Abstract Therapeutic monoclonal immunoglobulins (mAbs) are used to treat patients with a wide range of disorders including autoimmune diseases. As pharmaceutical companies bring more fully humanized therapeutic mAb drugs to the healthcare market analytical platforms that perform therapeutic drug monitoring (TDM) without relying on mAb specific reagents will be needed. In this study we demonstrate that liquid-chromatography?mass spectrometry (LC?MS) can be used to perform TDM of mAbs in the same manner as smaller nonbiologic drugs. The assay uses commercially available reagents combined with heavy and light chain disulfide bond reduction followed by light chain analysis by microflow-LC?electrospray ionization-quadrupole-time-of-flight mass spectrometry (ESI-Q-TOF MS). Quantification is performed using the peak areas from multiply charged mAb light chain ions using an in-house developed software package developed for TDM of mAbs. The data presented here demonstrate the ability of an LC?MS assay to quantify a therapeutic mAb in a large cohort of patients in a clinical trial. The ability to quantify any mAb in serum via the reduced light chain without the need for reagents specific for each mAb demonstrates the unique capabilities of LC?MS. This fact, coupled with the ability to phenotype a patient?s polyclonal repertoire in the same analysis further shows the potential of this approach to mAb analysis.
Concordance Between Anticardiolipin and Anti-B2-Glycoprotein Antibody Testing in Clinical Practice
Ettore, Michael, Murray, David , Melissa, Snyder, Adhikari, Laura

American Journal of Clinical Pathology | February 16, 2016 | Volume: 138 | Issue: suppl_1 | Pages: A258-A258

10.1093/ajcp/138.suppl1.239 Get It

Clonotypic Light Chain Peptides Identified for Monitoring Minimal Residual Disease in Multiple Myeloma without Bone Marrow Aspiration
Bergen, H. Robert, Dasari, Surendra , Dispenzieri, Angela , Mills, John R. , Ramı́rez-Alvarado, Marina , Tschumper, Renee C. , Jelinek, Diane F., Barnidge, David R. , Murray, David , Dispenzieri, Angela , Ramirez-Alvarado, Marina

Clinical Chemistry | October 1, 2015 | Volume: 62 | Issue: 1 | Pages: 243-251

10.1373/clinchem.2015.242651 Get It

Abstract BACKGROUND Analytically sensitive techniques for measuring minimal residual disease (MRD) in multiple myeloma (MM) currently require invasive and costly bone marrow aspiration. These methods include immunohistochemistry (IHC), flow cytometry, quantitative PCR, and next-generation sequencing. An ideal MM MRD test would be a serum-based test sensitive enough to detect low concentrations of Ig secreted from multifocal lesions. METHODS Patient serum with abundant M-protein before treatment was separated on a 1-dimensional SDS-PAGE gel, and the Ig light-chain (LC) band was excised, trypsin digested, and analyzed on a Q Exactive mass spectrometer by LC-MS/MS. We used the peptide's abundance and sequence to identify tryptic peptides that mapped to complementary determining regions of Ig LCs. The clonotypic target tryptic peptides were used to monitor MRD in subsequent serum samples with prior affinity enrichment. RESULTS Sixty-two patients were tested, 20 with no detectable disease by IHC and 42 with no detectable disease by 6-color flow cytometry. A target peptide that could be monitored was identified in 57 patients (91%). Of these 57, detectable disease by LC-MS/MS was found in 52 (91%). CONCLUSIONS The ability to use LC-MS/MS to measure disease in patients who are negative by bone marrow–based methodologies indicates that a serum-based approach has more analytical sensitivity and may be useful for measuring deeper responses to MM treatment. The method requires no bone marrow aspiration.
Using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry to detect monoclonal immunoglobulin light chains in serum and urine
Barnidge, David R. , Krick, Thomas P., Griffin, Timothy J. , Murray, David , Murray, David L., Griffin, Timothy J

Rapid Communications in Mass Spectrometry | October 1, 2015 | Volume: 29 | Issue: 21 | Pages: 2057-2060

10.1002/rcm.7314 Get It

Rationale Use of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) to monitor serum and urine samples for endogenous monoclonal immunoglobulins. MALDI‐TOFMS is faster, fully automatable, and provides superior specificity compared to protein gel electrophoresis (PEL). Methods Samples were enriched for immunoglobulins in 5 min using Melon Gel™ followed by reduction with dithiothreitol for 15 min to separate immunoglobulin light chains and heavy chains. Samples were then desalted using C4 ZipTips, mixed with sinapinic acid matrix, and analyzed on a Bruker Biflex III MALDI‐TOF mass spectrometer. Results Monoclonal immunoglobulin light chains were identified in serum and urine samples from patients with a known monoclonal gammopathy using MALDI‐TOFMS with minimal sample preparation. Conclusions MALDI‐TOFMS can identify a monoclonal immunoglobulin in serum and urine samples. The molecular mass of the monoclonal immunoglobulin light chain is obtained providing unprecedented specificity compared to PEL. In addition, the methodology can be automated, making it a practical alternative to PEL. Copyright © 2015 John Wiley & Sons, Ltd.
Monitoring IgA Multiple Myeloma: Immunoglobulin Heavy/Light Chain Assays
Katzmann, Jerry A., Kohlhagen, Mindy , Kyle, Robert A. , Murray, David , Snyder, Melissa R, Dispenzieri, Angela , Willrich, Maria Alice V. , Snyder, Melissa R, Rajkumar, S. Vincent , Dispenzieri, Angela

Clinical Chemistry | December 2, 2014 | Volume: 61 | Issue: 2 | Pages: 360-367

10.1373/clinchem.2014.231985 Get It

AbstractBACKGROUNDThe use of electrophoresis to monitor monoclonal immunoglobulins migrating in the β fraction may be difficult because of their comigration with transferrin and complement proteins.METHODSImmunoassays specific for IgGκ, IgGλ, IgAκ, IgAλ, IgMκ, and IgMλ heavy/light chain (HLC) were validated for use in the clinical laboratory. We assessed sample stability, inter- and intraassay variability, linearity, accuracy, and reference intervals for all 6 assays. We tested accuracy by verifying that the sum of the concentrations for the HLC-pairs accounted for the total immunoglobulins in each of 129 healthy sera, and that the HLC-pair ratios (rHLCs) were outside the reference interval in 97% of 518 diagnostic multiple myeloma (MM) samples.RESULTSWe assessed diagnostic samples and posttreatment sera in 32 IgG and 30 IgA patients for HLC concentrations, rHLC, and total immunoglobulins and compared these nephelometry results with serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). In sample sets from patients with IgG MM, the sensitivity of SPEP was almost the same as for rHLC, and no additional advantage was conferred by running HLC assays. In pre- and posttreatment samples from patients with IgA MM, the SPEP, rHLC, and IFE identified clonality in 28%, 56%, and 61%, respectively. In addition, when M-spikes were quantifiable, the concentration of the involved HLC was linearly related to that of the SPEP M-spike, with a slope near 1.CONCLUSIONSThe use of IgA HLC assays for monitoring β-migrating IgA monoclonal proteins can substitute for the combination of SPEP, IFE, and total IgA quantification.
Phenotyping Polyclonal Kappa and Lambda Light Chain Molecular Mass Distributions in Patient Serum Using Mass Spectrometry
Barnidge, David R. , Dasari, Surendra , Ramı́rez-Alvarado, Marina , Fontan, Adrian, Tschumper, Renee C. , Jelinek, Diane F., Snyder, Melissa R., Dispenzieri, Angela , Katzmann, Jerry A., Murray, David , Willrich, Maria Alice V. , Snyder, Melissa R., Dispenzieri, Angela , Ramirez-Alvarado, Marina

Journal of Proteome Research | August 19, 2014 | Volume: 13 | Issue: 11 | Pages: 5198-5205

10.1021/pr5005967 Get It

Detecting monoclonal light chains in urine: microLC‐ESI‐Q‐TOF mass spectrometry compared to immunofixation electrophoresis
Botz, Chad M. , Barnidge, David R. , Murray, David , Katzmann, Jerry A.

British Journal of Haematology | July 7, 2014 | Volume: 167 | Issue: 3 | Pages: 437-438

10.1111/bjh.13003 Get It

Quantification of Serum IgG Subclasses by Use of Subclass-Specific Tryptic Peptides and Liquid Chromatography–Tandem Mass Spectrometry
Ladwig, Paula M. , Barnidge, David R. , Snyder, Melissa R. , Katzmann, Jerry A., Murray, David , Murray, David L.

Clinical Chemistry | May 6, 2014 | Volume: 60 | Issue: 8 | Pages: 1080-1088

10.1373/clinchem.2014.222208 Get It

AbstractBACKGROUNDMeasurement of IgG subclasses is a useful tool for investigation of humoral immune deficiency in the presence of total IgG within reference intervals and IgG4-related disease. Nephelometry has been the method of choice for quantification. We describe an LC-MS/MS method that can multiplex all 4 subclasses along with total IgG by use of either IgG subclass-specific peptide stable isotope–labeled internal standards or a surrogate digest standard for quantification and does not rely on antigen/antibody reactions.METHODSWe combined serum with labeled internal peptide standards and intact purified horse IgG. Samples were denatured, reduced, alkylated, and digested. We analyzed the digested serum by LC-MS/MS for IgG subclasses 1–4 and total IgG.RESULTSWe assayed 112 patient sera by LC-MS/MS and immunonephelometry. The mean of the slopes and R2 values for IgG1, IgG2, IgG3, IgG4, and IgG were 1.18 and 0.93, respectively. Interassay imprecision for the LC-MS/MS method was <15% for total IgG and subclasses and was slightly improved by use of a calibrator peptide from an exogenous horse IgG. Summed total IgG correlated with the measured total IgG within 10%. Reference intervals and analytical measuring range were all similar to our previous validation data for the immunonephelometry assays.CONCLUSIONSTotal IgG and IgG subclasses 1, 2, 3, and 4 can be quantified by LC-MS/MS with performance comparable to nephelometry.