Background: The NanoScope, given its smaller size, may be further from critical structures when establishing volar wrist arthroscopy portals compared to the traditional 2.7-mm arthroscope. Methods: Ten fresh-frozen latex-injected cadaver specimens were utilized. The volar radial (VR) and volar ulnar (VU) portals were created using an inside-out approach. The volar radial midcarpal (VR-MC) and volar ulnar midcarpal (VU-MC) portals were created using an inside-out approach. The arm was then dissected under 3.5-mm loupe magnification. Digital calipers were used to measure the distance between the portals and the surrounding anatomic structures by two fellowship-trained hand surgeons. Results: The median nerve was on average 1.6, 7.2, 1.8, and 5.6 mm away from the trochar for the VR, VU, VR-MC, and VU-MC, respectively. The median nerve fascia was pierced by the VR portal in one specimen. The radial artery, ulnar artery, and ulnar nerve were not pierced in any specimen. Compared to historical controls, for the VR-MC portal, the NanoScope was further from all critical structures, aside from the radial artery, and did not pierce any neurovascular structures. For the VU-MC portal, the NanoScope was further from the ulnar artery and median nerve and did not pierce any neurovascular structures. Conclusion: In developing volar portals, after placing the cannula through the volar capsule from an inside-out approach, we recommend making a volar incision and dissecting the local anatomic structures to guard against injury. Compared to historical controls, the NanoScope was typically further from neurovascular structures.
Abstract Background Nanoscope, given its smaller size, may be safer when establishing dorsal wrist arthroscopy portals compared with the traditional 2.7 mm arthroscope. Case Description Ten fresh frozen cadaver specimens were utilized. Dorsal radiocarpal portals were established with the Nanoscope and calipers were used to measure the distance between the portals and the surrounding anatomical structures. The only structure that was pierced during portal placement was the dorsal sensory branch of the ulnar nerve (DSUN) in one specimen when establishing the 6U portal. Our study did not note any tendon injuries. Literature Review Traditional wrist arthroscopy may be performed with a 2.7 mm arthroscope. With its larger outer sheath cannula, this may place adjacent anatomical structures at risk of injury. Clinical Relevance During wrist arthroscopy, the Nanoscope may be safer when creating portals to underlying structures. Level of Evidence This is a Level IV study.
Preoperative Antibiotics Influence Culture Yield in the Treatment of Hand, Wrist, and Forearm Infections
Background: When treating upper-extremity infections, clinicians frequently must decide whether to initiate antibiotics or delay them with the goal of optimizing culture yield at the time of surgical debridement. The purpose of this study was to determine whether the administration of preoperative antibiotics affects intraoperative culture yield and whether there is a “safe” interval prior to culture acquisition within which antibiotics can be administered without affecting culture yield. Methods: We conducted a retrospective review of 470 consecutive patients who underwent debridement for a presumed acute infection of the hand, wrist, or forearm at a single tertiary care center between January 2015 and May 2020. Data including patient demographics, mechanism of infection and affected body part(s), and details of antibiotic administration, including type and timing with respect to culture acquisition, were collected. Results: Three hundred and forty-one patients (73%) received preoperative antibiotics prior to debridement and culture acquisition. The rate of positive cultures among patients who received preoperative antibiotics was 81% compared with 95% among patients who did not receive preoperative antibiotics (p < 0.01; odds ratio, 4.73). Even a single dose of antibiotics imparted a significantly increased risk of obtaining negative intraoperative cultures, and an incremental increase in the likelihood of obtaining negative cultures was seen with each preoperative dose given up to 7 doses. We did not identify a “safe” interval of time between antibiotic administration and culture acquisition such that culture yield was not affected. Conclusions: Patients who received preoperative antibiotics for the treatment of upper-extremity infections were approximately 5 times more likely to have negative cultures at the time of debridement than those who did not receive preoperative antibiotics. This effect persisted regardless of the number of doses given or the interval between antibiotic administration and culture acquisition. Level of Evidence: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Wrist Arthroscopy Using the 2R Portal: Is It Safer Than the 1,2 Portal?
Backgroud: The purpose of this study was to compare the 1,2 with a novel 2R portal in terms of proximity to critical structures. Methods: Wrist arthroscopy was performed on 8 fresh frozen cadavers via the 1,2 and 2R portals. External anatomy was then dissected under loupe magnification. The closest distance between the portals and surrounding anatomical structures was measured in millimeters using digital calipers. Results: The 1,2 portal was significantly closer to radial artery and first extensor compartment tendons than the 2R portal. The radial artery was on average 1.32 mm from the 1-2 portal and 14.25 mm from the 2R portal. The 2R portal was significantly closer to the second and third extensor compartment tendons. The closest branch of the superficial branch of the radial nerve (SBRN) was on average 2.04 mm from the 1-2 portal and 7.59 mm from the 2R portal, but this was not statistically significant. Conclusions: We advocate using the 2R portal preferentially to the 1,2 portal when treating radial sided wrist pathology to decrease the risk of iatrogenic radial artery and SBRN injury.