Back to Authors

Ramazanian, Taghi

https://orcid.org/0000-0002-6546-2148

Mayo Clinic

University of Central Florida

Citations 8

Mobile Technology for Measurement of Wrist Joint Range of Motion
Enayati, Moein , Ramazanian, Taghi , Kremers, Hilal Maradit

2025 Design of Medical Devices Conference | June 5, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2025-1015 Get It

Abstract The accurate measurement of wrist range of motion (ROM) is crucial for assessing functional impairments and monitoring recovery in clinical and rehabilitation settings. Traditional methods, such as Goniometric measurement, while effective, require clinician involvement and provide limited dynamic data. Recent advancements in wearable and smartphone-based technologies offer promising alternatives, enabling remote self-monitoring and dynamic assessments. This paper presents a novel smartphone-based application for measuring wrist ROM, leveraging built-in accelerometers and gyroscopes to capture joint motion with high accuracy. The app provides real-time feedback through visualizations and haptic or auditory cues, enhancing usability and ensuring accurate measurements without clinician supervision. By focusing on accessibility, affordability, and ease of use, the proposed app aims to bridge the gap between clinical and home-based care, offering a scalable solution for remote rehabilitation and continuous care. This paper discusses the current state of ROM measurement technologies, the design of the app, and its potential to improve patient engagement and outcomes in both clinical and home settings.
Automated Cobb Angle Measurement in Adolescent Idiopathic Scoliosis: Validation of a Previously-Published Deep Learning Method
Shi, Yan , Ramazanian, Taghi , Yan, Shi, Constant, Caroline , Kremers, Hilal Maradit , Larson, A. Noelle

2022 IEEE 10th International Conference on Healthcare Informatics (ICHI) | September 8, 2022 | Volume: No volume available | Issue: No issue available | Pages: 495-496

10.1109/ichi54592.2022.00085 Get It

Deep Learning Method for Hip Knee Ankle Angle Prediction on Postoperative Full-Limb Radiographs of Total Knee Arthroplasty Patients
Yan, Shi , Ramazanian, Taghi , Chaudhary, Vipin , Kremers, Hilal Maradit

2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) | September 8, 2022 | Volume: No volume available | Issue: No issue available | Pages: 5070-5073

10.1109/embc48229.2022.9870936 Get It

Deep Learning for Radiographic Measurement of Femoral Component Subsidence Following Total Hip Arthroplasty
Rouzrokh, Pouria , Wyles, Cody C. , Kurian, Shyam J. , Ramazanian, Taghi , Cai, Jason , Huang, Qiao , Zhang, Kuan , Kremers, Hilal Maradit , Erickson, Bradley J. , Maradit Kremers, Hilal , Erickson, Bradley J , Wyles, Cody C , Rouzrokh, Pouria , Taunton, Michael J.

Radiology: Artificial Intelligence | May 4, 2022 | Volume: 4 | Issue: 3 | Pages: No page available

10.1148/ryai.210206 Get It

Wrist Arthroscopy Using the 2R Portal: Is It Safer Than the 1,2 Portal?
Munaretto, Nicholas , Dutton, Lauren K. , Ramazanian, Taghi , Kakar, Sanjeev , Munaretto, Nicholas , Kakar, Sanjeev , Hinchcliff, Katharine M.

HAND | February 11, 2022 | Volume: 18 | Issue: 5 | Pages: 746-750

10.1177/15589447221075668 Get It

Backgroud: The purpose of this study was to compare the 1,2 with a novel 2R portal in terms of proximity to critical structures. Methods: Wrist arthroscopy was performed on 8 fresh frozen cadavers via the 1,2 and 2R portals. External anatomy was then dissected under loupe magnification. The closest distance between the portals and surrounding anatomical structures was measured in millimeters using digital calipers. Results: The 1,2 portal was significantly closer to radial artery and first extensor compartment tendons than the 2R portal. The radial artery was on average 1.32 mm from the 1-2 portal and 14.25 mm from the 2R portal. The 2R portal was significantly closer to the second and third extensor compartment tendons. The closest branch of the superficial branch of the radial nerve (SBRN) was on average 2.04 mm from the 1-2 portal and 7.59 mm from the 2R portal, but this was not statistically significant. Conclusions: We advocate using the 2R portal preferentially to the 1,2 portal when treating radial sided wrist pathology to decrease the risk of iatrogenic radial artery and SBRN injury.
The Turtle Neck Sign: Identification of Severe Retracted Distal Biceps Tendon Rupture
Boonrod, Artit , Harasymczuk, Michał , Ramazanian, Taghi , Boonrod, Arunnit, Smith, Jay , O’Driscoll, Shawn W. , Fitzsimmons, James S

Orthopaedic Journal of Sports Medicine | January 19, 2022 | Volume: 10 | Issue: 1 | Pages: No page available

10.1177/23259671211065030 Get It

Background: Chronic tendon retraction subsequent to distal biceps tendon rupture significantly increases repair difficulty and potential for tendon grafting. Biceps tendons that appear short or absent with magnetic resonance imaging (MRI) or that cannot be readily identified at surgery may erroneously be classified as irreparable. These apparent “absent” biceps tendons may actually be retracted and curled up inside the muscle, visually resembling the head-neck of a turtle retracted inside its shell (the “turtle neck sign”). When located, these tendons could be unfolded and repaired primarily. This type of tendon retraction seems to be associated with high-degree ruptures and larcertus fibrosus tears. Purpose: To test the hypothesis that tendon retractions with a turtle neck sign on MRI are more associated with high-degree ruptures and larcertus fibrosus tears versus tendon tears with simple linear retraction. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Retracted distal biceps tendon ruptures on sagittal MRI were categorized as linear retraction or curled-up (turtle neck) retraction. Retraction length, injury severity, and lacertus fibrosus tears were analyzed. Results: The authors retrospectively analyzed the patient records of 85 consecutive traumatic distal biceps tendon ruptures from 2003 to 2019; the final study cohort was 37 patients. Injury-to-surgery timing was as follows: <3 weeks, 43% (16 cases); 3 weeks to 3 months, 32% (12 cases); and >3 months, 24% (9 cases). Overall, 19 patients had linear retraction <7 cm (mean, 3.3 ± 1.9 cm) and 18 patients had a turtle neck retraction ≥7 cm (mean, 9.1 ± 1.6 cm). The injury-to-surgery time (median [± interquartile range]) was 27 days (±90 days) in the linear retraction group and 23 days (±65 days) in the turtle neck retraction group. The turtle neck retraction group had a significantly higher occurrence of abnormal hook test findings, complete distal biceps tendon rupture, and lacertus fibrosus tears compared with the linear retraction group (100% vs 58%, 100% vs 68%, and 100% vs 37%, respectively; P ≤ .02). However, significant repairability differences were not found. Conclusion: Highly retracted distal biceps turtle neck sign tendon ruptures occur frequently in association with high-degree ruptures and lacertus fibrosus tears. The presence of a turtle neck retraction did not affect reparability. Surgeons should be aware of this curled-up retraction to avoid mistaking it for an absent tendon or a muscle-tendon disruption.
Scapholunate ligament 360° procedure
Logli, Anthony L. , Ramazanian, Taghi , Gaston, R. Glenn , Fowler, John R. , Kakar, Sanjeev

The Bone & Joint Journal | May 5, 2021 | Volume: 103-B | Issue: 5 | Pages: 939-945

10.1302/0301-620x.103b5.bjj-2020-1964.r2 Get It

AimsThe purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability.MethodsWe studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test.ResultsBefore surgery, patients with SL instability were significantly impaired with respect to wrist flexion, extension, and grip strength (mean flexion, 51° (20° to 85°) vs 73° (45° to 90°); mean extension, 46° (15° to 70°) vs 66° (45° to 80°); mean grip strength, 25 kg (20 to 31) vs 50 kg (35 to 68) compared to the unaffected side). The mean SL gap (4.9 mm (2.3 to 7.3) vs 2.1 mm (1.6 to 2.9)) and mean SL angle (71° (59° to 105°) vs 50° (38° to 64°) were also significantly greater in the affected wrist. At final follow-up, there was mean improvement regarding clinical, radiological, and functional outcomes comparing preoperative to final postoperative values for the VAS for pain scale, QuickDASH, MWS, PRWE, and SL gap and SL angle.ConclusionIn our small series, the SL 360 procedure for reducible SL instability has favourable early clinical, patient-reported, and radiological outcomes at a mean of 33.7 months (12.0 to 51.3). The suture tape and tendon construct confers robust stability, permitting earlier mobilization without the inherent disadvantages of Kirschner wire stabilization. Cite this article: Bone Joint J 2021;103-B(5):939–945.
Effect of incremental increase in radial neck height on coronoid and capitellar contact pressures
Ramazanian, Taghi , Müller-Lebschi, Julia A., Chuang, Min-Yao , Vaichinger, Anthony M. , Fitzsimmons, James S. , O’Driscoll, Shawn W. , Fitzsimmons, James S

Shoulder & Elbow | October 30, 2019 | Volume: 13 | Issue: 4 | Pages: 445-450

10.1177/1758573219881772 Get It

Background Over-lengthening of the radial neck has been shown to affect ulnohumeral kinematics and has been proposed to affect radiocapitellar pressures. We hypothesized that an incremental increase in radial neck height increases the capitellar contact pressure and reduces the coronoid contact pressure. Knowledge of the effects of over-lengthening is clinically important in preventing pain and degenerative changes due to overstuffing. Methods Six human cadaveric elbows were prepared on a custom-designed apparatus simulating muscle loads and passive flexion from 0° to 90° under gravity valgus torque while measuring joint contact pressures in this biomechanical study. Each elbow was tested sequentially starting with the intact specimen followed by insertion of a radial head prosthesis with 0, +2, and +4 mm of radial neck height, respectively. Results Capitellar mean contact pressures significantly increased after insertion of +2 and +4 mm radial head prostheses (p < 0.03). The capitellar mean contact pressure with a 0 mm radial head prosthesis was 97 KPa. Insertion of +2 mm and +4 mm radial heads increased mean contact pressures to 391 KPa (p = 0.001) and 619 KPa (p = 0.001), respectively, with 90° of elbow flexion. Discussion Increasing radial prosthesis height by 2 mm significantly increases capitellar contact pressures and reduces coronoid contact pressures.