Back to Authors

Bogle, Jamie

Mayo Clinic

Mayo Clinic Hospital

Citations 4

Impact of Vestibular Schwannoma Management on Cochlear Implant Programming and Outcomes
Kolberg, Courtney, Bogle, Jamie M. , DeJong, Melissa D., Deep, Nicholas L. , Weisskopf, Peter A., Dornhoffer, James R. , Neff, Brian A., Driscoll, Colin L. W., Carlson, Matthew L., Saoji, Aniket A. , Bogle, Jamie, Deep, Nicholas, Weisskopf, Peter, Carlson, Matthew L.

Otology & Neurotology | June 6, 2025 | Volume: 46 | Issue: 8 | Pages: 903-908

10.1097/mao.0000000000004572 Get It

Objectives To compare electrical stimulation and speech perception in vestibular schwannoma (VS) patients across treatment modalities and standard cochlear implant (CI) patients. Study Design Retrospective review. Setting Tertiary academic center. Patients Sixty-seven CI ears consisting of 23 standard CI controls and 44 VS patients with ipsilateral CI. VS patients were separated by treatment modality: 24 microsurgical resection, 15 radiation therapy, and 5 observation. Eleven VS patients with CI did not receive auditory sensation from electrical stimulation. Interventions VS microsurgical resection, radiation therapy, and observation. Main Outcome Measures Threshold (T-levels), comfort (C-levels), consonant-nucleus-consonant (CNC) word score, and AzBio sentence recognition scores. Results Patients who underwent microsurgical resection required significantly higher (p < 0.001) T-levels and C-levels compared with the standard CI group. Stimulation levels in the VS radiation therapy and observation groups were higher but not significantly different compared with standard CI controls. Overall rate of CI nonstimulation across all VS patients was 25%: 38% for microsurgery and 13% for radiation. Average CNC score for microsurgery group was 18% compared with 44% for radiation, 55% for observation, and 68.5% for standard CI controls. CNC word and AzBio scores were significantly lower (p < 0.001) for the microsurgery group compared with standard CI group. Conclusions Resection may negatively affect auditory nerve function, leading to higher stimulation levels, increased risk of nonstimulation, and poorer postoperative CI speech outcomes compared with observation or radiosurgery. When medically appropriate, nonsurgical VS management may be used to allow for optimization of CI programming and postoperative hearing outcomes.
Baseline Normative and Test–Retest Reliability Data for Sideline Concussion Assessment Measures in Youth
Wethe, Jennifer V. , Bogle, Jamie M. , Howard, Marci, Gould, Amanda Rach, Butterfield, Richard , Buras, Matthew , Adler, Jennifer S. , Talaber, Alexandra , Soma, David , Starling, Amaal J. , Bogle, Jamie, Howard, Marci D, Buras, Matthew R , Adler, Jennifer, Starling, Amaal J , Wethe, Jennifer V , Dodick, David W.

Diagnostics | August 1, 2024 | Volume: 14 | Issue: 15 | Pages: 1661

10.3390/diagnostics14151661 Get It

Tools used for the identification, evaluation, and monitoring of concussion have not been sufficiently studied in youth or real-world settings. Normative and reliability data on sideline concussion assessment measures in the youth athlete population is needed. Pre-season normative data for 515 athletes (93.5% male) aged 5 to 16 on the Standardized Assessment of Concussion (SAC/SAC-Child), modified Balance Errors Scoring System (mBESS), Timed Tandem Gait (TTG), and the King–Devick Test (KDT) are provided. A total of 212 non-injured athletes repeated the measures post-season to assess test–retest reliability. Mean performance on the SAC-C, mBESS, TTG, and KDT tended to improve with age. KDT was the only measure that demonstrated good to excellent stability across age ranges (ICC = 0.758 to 0.941). Concentration was the only SAC/SAC-C subtest to demonstrate moderate test–retest stability (ICC = 0.503 to 0.706). TTG demonstrated moderate to good (ICC = 0.666 to 0.811) reliability. mBESS demonstrated poor to moderate reliability (ICC = −0.309 to 0.651). Commonly used measures of concussion vary regarding test–retest reliability in youth. The data support the use of at least annual sport concussion baseline assessments in the pediatric population to account for the evolution in performance as the child ages. Understanding the variation in the stability and the evolution of baseline performance will enable improved identification of possible injury.
Oculomotor and Perceptual Measures of Visual Motion Sensitivity in Patients With Chronic Dizziness Symptoms
Zaleski-King, Ashley, Pinto, Robin, Tamaki, Chizuko, Bogle, Jamie, McCaslin, Devin, Brungart, Douglas, Bogle, Jamie M. , Zaleski-King, Ashley, Pinto, Robin, Tamaki, Chizuko, McCaslin, Devin, Brungart, Douglas S.

Ear & Hearing | January 25, 2022 | Volume: 43 | Issue: 5 | Pages: 1515-1525

10.1097/aud.0000000000001206 Get It

Objective: The purpose of this study was to provide empirical data describing the relationship between behavioral responses to dynamic visual motion in adults with chronic dizziness symptoms with and without clinically identifiable peripheral vestibular impairment. Design: Prospective, quasi-experimental study including individuals with chronic dizziness symptoms with identified unilateral peripheral vestibular impairment (n=27), and individuals with chronic dizziness symptoms without identified vestibular impairment (n=26). We measured (a) visual perception of verticality in a dynamic background, (b) postural displacement in a dynamic background, (c) eye movement behaviors in various visual contexts, and (d) self-rating degree of anxiety. Results: Status of peripheral vestibular function was not a significant predictor of behavioral responses to visual motion. The data show that the ability to fixate on a visual target was predictive of postural control in a dynamic visual background. Trial-to-trial variability in verticality responses and degree of self-rated anxiety were also associated with postural control. Conclusions: Apart from vestibular function, oculomotor control is important for maintaining control of whole-body motor responses during exposure to a dynamic visual stimulus. Vertical perception precision—not accuracy—may be more important for understanding real-world consequences of visual motion sensitivity. Traditional diagnostic evaluations focusing exclusively on characterizing the peripheral vestibular system may not provide insight into the behaviors associated with visual motion sensitivity.
CEDRA: A Tool to Help Consumers Assess Risk for Ear Disease
Klyn, Niall A. M. , Bogle, Jamie M. , Alfakir, Razan , Nielsen, Donald W., Carlson, Deborah , Lundy, Larry, Dhar, Sumitrajit , Zapala, David A., Kleindienst Robler, Samantha, Bogle, Jamie, Alfakir, Razan , Robler, Samantha Kleindienst , Griffith, James William , Carlson, Deborah L.

Ear & Hearing | April 5, 2019 | Volume: 40 | Issue: 6 | Pages: 1261-1266

10.1097/aud.0000000000000731 Get It

This article introduces the Consumer Ear Disease Risk Assessment (CEDRA) tool. CEDRA is a brief questionnaire designed to screen for targeted ear diseases. It offers an opportunity for consumers to self-screen for disease before seeking a hearing device and may be used by clinicians to help their patients decide the appropriate path to follow in hearing healthcare. Here we provide highlights of previously published validation in the context of a more thorough description of CEDRA’s development and implementation. CEDRA’s sensitivity and specificity, using a cut-off score of 4 or higher, was 90% and 72%, respectively, relative to neurotologist diagnoses in the initial training sample used to create the scoring algorithm (n = 246). On a smaller independent test sample (n = 61), CEDRA’s sensitivity and specificity were 76% and 80%, respectively. CEDRA has readability levels similar to many other patient-oriented questionnaires in hearing healthcare, and informal reports from pilot CEDRA-providers indicate that the majority of patients can complete it in less than 10 min. As the hearing healthcare landscape changes and provider intercession is no longer mandated, CEDRA provides a measure of safety without creating a barrier to access.