Safety and Performance of a Novel Implantable Sensor in the Inferior Vena Cava Under Acute and Chronic Intravascular Volume Modulation
Sheridan, William S., Wetterling, Friedrich , Fudim, Marat , Damman, Kevin , Gray, Alastair , Gaines, P.A. , Poloczek, Martin, Madden, Stephen F. , Buxó, Teresa , Gaul, Robert , Corcoran, Louise, Sweeney, Fiachra, Testani, Jeffrey M. , Borlaug, Barry A. , Tucker, James, Burkhoff, Daniel

European Journal of Heart Failure | March 9, 2023 | Volume: 25 | Issue: 5 | Pages: 754-763

10.1002/ejhf.2822 Get It

ABSTRACT Aims The management of congestion is one of the key treatment targets in heart failure. Assessing congestion is, however, difficult. The purpose of this study was to investigate the safety and dynamic response of a novel, passive, inferior vena cava (IVC) sensor in a chronic ovine model. Methods and results A total of 20 sheep divided into three groups were studied in acute and chronic in vivo settings. Group I and Group II included 14 sheep in total with 12 sheep receiving the sensor and two sheep receiving a control device (IVC filter). Group III included an additional six animals for studying responses to volume challenges via infusion of blood and saline solutions. Deployment was 100% successful with all devices implanted; performing as expected with no device-related complications and signals were received at all observations. At similar volume states no significant differences in IVC area normalized to absolute area range were measured (55 ± 17% on day 0 and 62 ± 12% on day 120, p = 0.51). Chronically, the sensors were completely integrated with a thin, reendothelialized neointima with no loss of sensitivity to infused volume. Normalized IVC area changed significantly from 25 ± 17% to 43 ± 11% (p = 0.007) with 300 ml infused. In contrast, right atrial pressure required 1200 ml of infused volume prior to a statistically significant change from 3.1 ± 2.6 mmHg to 7.5 ± 2.0 mmHg (p = 0.02). Conclusion In conclusion, IVC area can be measured remotely in real-time using a safe, accurate, wireless, and chronic implantable sensor promising to detect congestion with higher sensitivity than filling pressures.
Changes in inferior vena cava area represent a more sensitive metric than changes in filling pressures during experimental manipulation of intravascular volume and tone
Wetterling, Friedrich , Gaul, Robert , Sheridan, Stephen, Asher, Jennifer L. , Rao, Veena S. , Mahoney, Devin , Mebazaa, Alexandre , Gray, Alastair , Cowie, Martín , Fudim, Marat , McDonald, Kenneth , Damman, Kevin , Cowie, Martin R , Ivey-Miranda, Juan B , Maulion, Christopher , Burkhoff, Daniel , Cox, Zachary L , Butler, Javed , Borlaug, Barry A. , Testani, Jeffrey M.

European Journal of Heart Failure | November 27, 2021 | Volume: 24 | Issue: 3 | Pages: 455-462

10.1002/ejhf.2395 Get It

Aims Remote monitoring of pulmonary artery pressure has reduced heart failure (HF) hospitalizations in chronic HF as elevation of pulmonary artery pressure provides information that can guide treatment. The venous system is characterized by high capacitance, thus substantial increases in intravascular volume can occur before filling pressures increase. The inferior vena cava (IVC) is a highly compliant venous conduit and thus a candidate for early detection of change in intravascular volume. We aimed to compare IVC cross‐sectional area using a novel sensor with cardiac filling pressures during experimental manipulation of volume status, vascular tone, and cardiac function. Methods and results Experiments were conducted in sheep to manipulate volume status (colloid infusion), vascular tone (nitroglycerin infusion) and cardiac function (rapid cardiac pacing). A wireless implantable IVC sensor was validated ex‐vivo and in‐vivo , and then used to measure the cross‐sectional area of the IVC. Right‐ and left‐sided cardiac filling pressures were obtained via right heart catheterization. The IVC sensor provided highly accurate and precise measurements of cross‐sectional area in ex‐vivo and in‐vivo validation. IVC area changes were more sensitive than the corresponding changes in cardiac filling pressures during colloid infusion ( p < 0.001), vasodilatation ( p < 0.001) and cardiac dysfunction induced by rapid pacing ( p ≤ 0.02). Conclusions Inferior vena cava area can be remotely and accurately measured in real time with a wireless implantable sensor. Changes in IVC area are more sensitive than corresponding changes in filling pressures following experimental volume loading and fluid redistribution. Additional research is warranted to understand if remote monitoring of the IVC may have advantages over pressure‐based monitors in HF.