Improvement in Renal Function During the Treatment of Acute Decompensated Heart Failure: Relationship With Markers of Renal Tubular Injury and Prognostic Importance
Background: Improvement in renal function (IRF) in acute decompensated heart failure is associated with adverse outcomes. The mechanisms driving this paradox remain undefined. Methods: Using the ROSE-AHF study (Renal Optimization Strategies Evaluation–Acute Heart Failure), 277 patients were grouped according to renal function, with IRF defined by a ≥20% increase (N=75), worsening renal function by a ≥20% decline (N=53), and stable renal function (SRF) by a <20% change (N=149) in estimated glomerular filtration rate between baseline and 72 hours. Three well-validated renal tubular injury markers, NGAL (neutrophil gelatinase-associated lipocalin), NAG (N-acetyl-β-d-glucosaminidase), and KIM-1 (kidney injury molecule 1), were evaluated at baseline and 72 hours. Patients were also classified by the pattern of change in these markers. Results: Patients with IRF had the lowest admission estimated glomerular filtration rate (IRF, 37 [28 to 51] mL/min per 1.73 m 2 ; worsening renal function, 43 [35 to 55] mL/min per 1.73 m 2 ; and SRF, 43 [32 to 55] mL/min per 1.73 m 2 ; P trend =0.032) but greater cumulative urine output (IRF, 8780 [7025 to 11 208] mL; worsening renal function, 7860 [5555 to 9765] mL; and SRF, 8150 [6325 to 10 456] mL; P trend =0.024) and weight loss (IRF, –9.0 [–12.4 to –5.3] lb; worsening renal function, –5.1 [–8.1 to –1.3] lb; and SRF, –7.1 [–11.9 to –3.2] lb; P trend <0.001) despite similar diuretic doses ( P trend =0.16). There were no differences in the relative change in NGAL, NAG, or KIM-1 between renal function groups ( P trend >0.19 for all). Patients with IRF had worse survival than patients with SRF (27% versus 54%; hazard ratio, 1.98 [1.10–3.58]; P =0.024). Conclusions: IRF during decongestive therapy for acute decompensated heart failure was not associated with improved markers of renal tubular injury and was associated with worsened survival, likely driven by the presence of greater underlying cardiorenal dysfunction and more severe congestion.
Changes in inferior vena cava area represent a more sensitive metric than changes in filling pressures during experimental manipulation of intravascular volume and tone
Aims Remote monitoring of pulmonary artery pressure has reduced heart failure (HF) hospitalizations in chronic HF as elevation of pulmonary artery pressure provides information that can guide treatment. The venous system is characterized by high capacitance, thus substantial increases in intravascular volume can occur before filling pressures increase. The inferior vena cava (IVC) is a highly compliant venous conduit and thus a candidate for early detection of change in intravascular volume. We aimed to compare IVC cross‐sectional area using a novel sensor with cardiac filling pressures during experimental manipulation of volume status, vascular tone, and cardiac function. Methods and results Experiments were conducted in sheep to manipulate volume status (colloid infusion), vascular tone (nitroglycerin infusion) and cardiac function (rapid cardiac pacing). A wireless implantable IVC sensor was validated ex‐vivo and in‐vivo , and then used to measure the cross‐sectional area of the IVC. Right‐ and left‐sided cardiac filling pressures were obtained via right heart catheterization. The IVC sensor provided highly accurate and precise measurements of cross‐sectional area in ex‐vivo and in‐vivo validation. IVC area changes were more sensitive than the corresponding changes in cardiac filling pressures during colloid infusion ( p < 0.001), vasodilatation ( p < 0.001) and cardiac dysfunction induced by rapid pacing ( p ≤ 0.02). Conclusions Inferior vena cava area can be remotely and accurately measured in real time with a wireless implantable sensor. Changes in IVC area are more sensitive than corresponding changes in filling pressures following experimental volume loading and fluid redistribution. Additional research is warranted to understand if remote monitoring of the IVC may have advantages over pressure‐based monitors in HF.
Arrhythmias in Cardiac Sarcoidosis Bench to Bedside
Cardiac sarcoidosis is a component of an often multiorgan granulomatous disease of still uncertain cause. It is being recognized with increasing frequency, mainly as the result of heightened awareness and new diagnostic tests, specifically cardiac magnetic resonance imaging and 18 F-fluorodeoxyglucose positron emission tomography scans. The purpose of this case-based review is to highlight the potentially life-saving importance of making the early diagnosis of cardiac sarcoidosis using these new tools and to provide a framework for the optimal care of patients with this disease. We will review disease mechanisms as currently understood, associated arrhythmias including conduction abnormalities, and atrial and ventricular tachyarrhythmias, guideline-directed diagnostic criteria, screening of patients with extracardiac sarcoidosis, and the use of pacemakers and defibrillators in this setting. Treatment options, including those related to heart failure, and those which may help clarify disease mechanisms are included.