37 cases of Mycoplasma pneumoniae pneumonia were diagnosed in children in North Dakota, over 3.5 months (35 by PCR); 44% harbored macrolide-resistance. Children with macrolide-resistant M. pneumoniae had a longer period of coughing prior to diagnosis (+ 3.9 days, p=0.048), a longer duration of illness (+ 5.4 days, p=0.011) and earlier resolution of fever after initiation of doxycycline (- 0.92 days, p=0.025) compared to those without macrolide resistant M. pneumoniae.
Macrolide-Resistant Mycoplasma pneumoniae, North Dakota 2024
Abstract A cluster of macrolide-resistant Mycoplasma pneumoniae -causing community-acquired pneumonia was observed in children in North Dakota in 2024. Suspicion was raised by non-response to macrolides, with confirmation via a polymerase-chain reaction assay. Prompt improvement occurred after the initiation of alternative antibiotics.
Testing for
Helicobacter pylori
in an era of antimicrobial resistance
The epidemiology of macrolide resistance in Mycoplasma ( Mycoplasmoides ) pneumoniae in the United States is incompletely described. Using a PCR assay targeting common mutations associated with macrolide resistance in M. pneumoniae (23S rRNA gene, A2063G/A2064G), the frequency of macrolide resistance was estimated to be 10% based on analysis of 114 samples tested from January 2014 to September 2021 at Mayo Clinic Laboratories.
Performance Comparison of Multiplexed Fluorescent Resonance Emission Transfer Hybridization Probes Across Roche LightCycler® Real-Time PCR Systems for the Detection of Bartonella species
Abstract Introduction/Objective Molecular assays for Bartonella species are important in diagnosing infection and expediting patient treatment. Real time polymerase chain reaction (RT-PCR) using fluorescent resonance energy transfer (FRET) hybridization probes can be used to detect Bartonella species in blood and fresh/fixed tissue biopsies in RT-PCR instruments. Over time, new technologies and reagents are introduced and existing PCR primers and FRET probes must be re-validated on new platforms. This study aimed to compare the performance of a Bartonella RT-PCR assay using the sunsetting Roche LightCycler® 2.0 (Roche Diagnostics, Indianapolis, IN) and newer LightCycler® 480 RT- PCR instruments. Methods/Case Report DNA was extracted from 132 historically positive, whole organism spiked, and historically negative whole blood and formalin fixed paraffin embedded (FFPE) samples. Samples were run on the LightCycler® 2.0 using instrument specific LightCycler® FastStart DNA Master HybProbe enzyme and compared to results generated using the LightCycler® 480 and its instrument specific LightCycler® 480 Genotyping Master enzyme. During optimization, MgCl2 concentrations and thermocycling profiles were adjusted. Accuracy, specificity, inclusivity, and limit of detection studies were performed. Crossing point (Cp), melting temperature (Tm), fluorescent peak and fluorescent background values were compared between the two instruments. Results (if a Case Study enter NA) The agreement in accuracy between the LightCycler® 2.0 and the LightCycler® 480 was 100% for whole blood samples. For historically positive FFPE samples, LightCycler® 2.0 sensitivity and LightCycler® 480 sensitivity were 86% and 100%, respectively. Specificity and inclusivity of the assay were identical between the two instruments. The limit of detection in whole blood was 5-fold lower on the LightCycler® 480 (50 copies/µL) compared to the LightCycler® 2.0 (250 copies/µL). Mean Cp and fluorescent peak intensity values increased by 5.1% and 65-fold, respectively. Conclusion The study demonstrates similar performance and improved limit of detection for the Bartonella FRET hybridization probe RT-PCR assay on the LightCycler® 480 compared to the LightCycler® 2.0.