Back to Authors

Berent, Taylor E.

https://orcid.org/0000-0002-9421-7176

Mayo Clinic

Mayo Clinic

Citations 3

Corynebacterium mayonis sp. nov. isolated from a human blood culture
Mohammed, Hamidu T. , Koscianski, Christina, Berent, Taylor E. , Gordy, Garrett G. , Herren, Sebastian , Patel, Robin , Koscianski, Christina A, Herren, Sebastian C , Patel, Robin , Johnson, Stephen A.

International Journal of Systematic and Evolutionary Microbiology | January 31, 2025 | Volume: 75 | Issue: 1 | Pages: No page available

10.1099/ijsem.0.006632 Get It

A novel Corynebacterium species, strain BD556T, isolated from blood, was identified at Mayo Clinic, Rochester, MN, USA. After failing definitive identification using MALDI-ToF MS and partial 16S rRNA gene sequencing, BD556T was characterized using a polyphasic approach, including phenotypic, biochemical and whole-genome sequencing methods. BD556T was a Gram-positive rod with clubbed ends, facultatively anaerobic, catalase-positive, oxidase-negative and non-motile. Colonies were white, opaque and non-haemolytic with halo-like edges. BD556T grew at 35 °C in room air, with CO2 and under anaerobic conditions. BD556T grew well in 0 and 6% NaCl and weakly in 10% NaCl. The genome size was 2 349 779 bp with a G+C content of 60.39%. Phylogenetic analysis using 16S rRNA gene sequence analysis, average nucleotide identity and digital DNA–DNA hybridization between the genome of BD556T and the closest type strains from the Type Strain Genome Server database yielded separation values well beyond those required for species delineation. Chemotaxonomic analyses of BD556T revealed ribose, arabinose and galactose as whole-cell sugars and an A1γ meso-diaminopimelic acid-direct peptidoglycan type. The major cellular fatty acids were C15 : 0 (21.0%), C16 : 0 (14.8%), C17 : 1 ω9c (26.2%), C17 : 0 (13.3%) and C18 : 1 ω9c (18.3%). Polar lipids included diphosphatidylglycerol, phosphatidylglycerol and unidentified glycolipids and phospholipids. BD556T also contained mycolic acids (32–36 carbons) typical of corynebacteria. The respiratory quinones were dominated by MK-8(H2) (71.2%) and MK-9(H2) (25.9%), with smaller amounts of MK-7(H2) and MK-10(H2). The results presented support the tenet that BD556T (=TSD 427T=NCTC 15078T) is a novel species for which the name Corynebacterium mayonis sp. nov. is proposed.
Hyperphosphatemia with Elevated Serum FGF-23 and PTH, Reduced Calcitriol, and Normal FGF7 Concentrations Characterizes Chronic Renal Failure in Humans
Losbanos, Louis, Berent, Taylor E. , Ashrafzadeh‐Kian, Susan , Hines, Jolaine M., Kritmetapak, Kittrawee , Algeciras‐Schimnich, Alicia , Singh, Ravinder J. , Kumar, Rajiv

Journal of the American Society of Nephrology | May 17, 2024 | Volume: 31 | Issue: 10S | Pages: 162-162

10.1681/asn.20203110s1162a Get It

Performance Comparison of Multiplexed Fluorescent Resonance Emission Transfer Hybridization Probes Across Roche LightCycler® Real-Time PCR Systems for the Detection of Bartonella species
Berent, Taylor E. , Rothstein, Tanner E. , Buckwalter, Seanne P., Patel, Robin

American Journal of Clinical Pathology | October 31, 2021 | Volume: 156 | Issue: Supplement_1 | Pages: S134-S135

10.1093/ajcp/aqab191.287 Get It

Abstract Introduction/Objective Molecular assays for Bartonella species are important in diagnosing infection and expediting patient treatment. Real time polymerase chain reaction (RT-PCR) using fluorescent resonance energy transfer (FRET) hybridization probes can be used to detect Bartonella species in blood and fresh/fixed tissue biopsies in RT-PCR instruments. Over time, new technologies and reagents are introduced and existing PCR primers and FRET probes must be re-validated on new platforms. This study aimed to compare the performance of a Bartonella RT-PCR assay using the sunsetting Roche LightCycler® 2.0 (Roche Diagnostics, Indianapolis, IN) and newer LightCycler® 480 RT- PCR instruments. Methods/Case Report DNA was extracted from 132 historically positive, whole organism spiked, and historically negative whole blood and formalin fixed paraffin embedded (FFPE) samples. Samples were run on the LightCycler® 2.0 using instrument specific LightCycler® FastStart DNA Master HybProbe enzyme and compared to results generated using the LightCycler® 480 and its instrument specific LightCycler® 480 Genotyping Master enzyme. During optimization, MgCl2 concentrations and thermocycling profiles were adjusted. Accuracy, specificity, inclusivity, and limit of detection studies were performed. Crossing point (Cp), melting temperature (Tm), fluorescent peak and fluorescent background values were compared between the two instruments. Results (if a Case Study enter NA) The agreement in accuracy between the LightCycler® 2.0 and the LightCycler® 480 was 100% for whole blood samples. For historically positive FFPE samples, LightCycler® 2.0 sensitivity and LightCycler® 480 sensitivity were 86% and 100%, respectively. Specificity and inclusivity of the assay were identical between the two instruments. The limit of detection in whole blood was 5-fold lower on the LightCycler® 480 (50 copies/µL) compared to the LightCycler® 2.0 (250 copies/µL). Mean Cp and fluorescent peak intensity values increased by 5.1% and 65-fold, respectively. Conclusion The study demonstrates similar performance and improved limit of detection for the Bartonella FRET hybridization probe RT-PCR assay on the LightCycler® 480 compared to the LightCycler® 2.0.