Back to Authors

Sánchez‐Sotelo, Joaquín

https://orcid.org/0000-0003-3199-3247

Mayo Clinic

Mayo Clinic

Citations 141

2018 International Consensus Meeting on Musculoskeletal Infection: Research Priorities from the General Assembly Questions
Schwarz, Edward M. , Gehrke, Thorsten , Aiyer, Amiethab A. , Battenberg, Andrew K. , Brown, Scot , Callaghan, John J. , Egol, Kenneth A. , Garrigues, Grant E. , Ghert, Michelle , Goswami, Karan , Hammound, Sommer, McLaren, A. C. , Mont, Michael A. , Namdari, Surena , Obremskey, William T. , O’Toole, Robert V. , Raikin, Steven M. , Restrepo, Camilo , Ricciardi, Benjamin F. , Saeed, Kordo , Shohat, Noam , Tan, Timothy L. , Thirukumaran, Caroline P. , Winters, Brian S., Sanchez-Sotelo, Joaquin, Schwarz, Edward M , Parvizi, Javad , Gehrke, Thorsten A. , Çıtak, Mustafa , Green, Andrew , Kates, Stephen L. , Sánchez‐Sotelo, Joaquín

Journal of Orthopaedic Research | April 12, 2019 | Volume: 37 | Issue: 5 | Pages: 997-1006

10.1002/jor.24293 Get It

ABSTRACT Musculoskeletal infections (MSKI) remain the bane of orthopedic surgery, and result in grievous illness and inordinate costs that threaten healthcare systems. As prevention, diagnosis, and treatment has remained largely unchanged over the last 50 years, a 2nd International Consensus Meeting on Musculoskeletal Infection (ICM 2018, https://icmphilly.com ) was completed. Questions pertaining to all areas of MSKI were extensively researched to prepare recommendations, which were discussed and voted on by the delegates using the Delphi methodology. The questions, including the General Assembly (GA) results, have been published ( GA questions ). However, as critical outcomes include: (i) incidence and cost data that substantiate the problems, and (ii) establishment of research priorities; an ICM 2018 research workgroup (RW) was assembled to accomplish these tasks. Here, we present the result of the RW consensus on the current and projected incidence of infection, and the costs per patient, for all orthopedic subspecialties, which range from 0.1% to 30%, and $17,000 to $150,000. The RW also identified the most important research questions. The Delphi methodology was utilized to initially derive four objective criteria to define a subset of the 164 GA questions that are high priority for future research. Thirty‐eight questions (23% of all GA questions) achieved the requisite > 70% agreement vote, and are highlighted in this Consensus article within six thematic categories: acute versus chronic infection, host immunity, antibiotics, diagnosis, research caveats, and modifiable factors. Finally, the RW emphasizes that without appropriate funding to address these high priority research questions, a 3rd ICM on MSKI to address similar issues at greater cost is inevitable.
Automated three-dimensional measurements of version, inclination, and subluxation
Shukla, Dave R. , McLaughlin, Richard J. , Lee, Julia , Nguyen, Ngoc Tram V. , Sanchez-Sotelo, Joaquin, Sánchez‐Sotelo, Joaquín , Shukla, Dave R.

Shoulder & Elbow | February 6, 2019 | Volume: 12 | Issue: 1 | Pages: 31-37

10.1177/1758573218825480 Get It

Background Preoperative planning software has been developed to measure glenoid version, glenoid inclination, and humeral head subluxation on computed tomography (CT) for shoulder arthroplasty. However, most studies analyzing the effect of glenoid positioning on outcome were done prior to the introduction of planning software. Thus, measurements obtained from the software can only be extrapolated to predict failure provided they are similar to classic measurements. The purpose of this study was to compare measurements obtained using classic manual measuring techniques and measurements generated from automated image analysis software. Methods Ninety-five two-dimensional computed tomography scans of shoulders with primary glenohumeral osteoarthritis were measured for version according to Friedman method, inclination according to Maurer method, and subluxation according to Walch method. DICOM files were loaded into an image analysis software (Blueprint, Wright Medical) and the output was compared with values obtained manually using a paired sample t-test. Results Average manual measurements included 13.8° version, 13.2° inclination, and 56.2% subluxation. Average image analysis software values included 17.4° version (3.5° difference, p < 0.0001), 9.2° inclination (3.9° difference, p < 0.001), and 74.2% for subluxation (18% difference, p < 0.0001). Conclusions Glenoid version and inclination values from the software and manual measurement on two-dimensional computed tomography were relatively similar, within approximately 4°. However, subluxation measurements differed by approximately 20%.
Patient-reported activities after bilateral reverse total shoulder arthoplasties
Assenmacher, Andrew T. , Aronowitz, Jessica G., Kergosien, Matthew, Schleck, Cathy D. , Cofield, Robert H. , Sperling, John W. , Alentorn-Geli, Eduard, Aronowitz, Jessica, Sanchez-Sotelo, Joaquin, Alentorn‐Geli, Eduard , Sánchez‐Sotelo, Joaquín

Journal of Orthopaedic Surgery | December 10, 2018 | Volume: 27 | Issue: 1 | Pages: No page available

10.1177/2309499018816771 Get It

Purpose: Reverse shoulder arthroplasty (RSA) improves pain and function with very good satisfaction. Concerns exist about some activities of daily living (ADLs) involving internal rotation. The purpose of this study was to report how patients with bilateral RSA perform various ADLs. Methods: Thirty-one primary bilateral RSA patients (average age 76 years; 21 women and 10 men) completed a survey to assess various outcomes. The average time between the second arthroplasty and the survey was 2.7 years (range 1.0–7.8 years). Results: All clinical parameters were favorable. All patients reported being able to easily manage toileting and 87% reaching their back pocket. However, 29% found difficulty and 39% were unable to wash their back or put on bra. In comparison with various unilateral arthroplasty types, there was no statistical difference in overall activities ( p < 0.05). Conclusion: Bilateral RSA can provide good functional outcome and high satisfaction. Patients manage most ADLs easily with some limitations in activities requiring extreme internal rotation.
Infographic: Replacing failed reverse shoulder arthroplasties as a reliable revision approach
Wagner, Eric R. , Cofield, Robert H. , Sperling, John W. , Wagner, Eric R , Hevesi, Mario , Houdek, Matthew T. , Sánchez‐Sotelo, Joaquín

The Bone & Joint Journal | November 12, 2018 | Volume: 100-B | Issue: 11 | Pages: 1491-1492

10.1302/0301-620x.100b11.bjj-2018-1139 Get It

Can a reverse shoulder arthroplasty be used to revise a failed primary reverse shoulder arthroplasty?
Wagner, Eric R. , Cofield, Robert H. , Sperling, John W. , Wagner, Eric R , Hevesi, Mario , Houdek, Matthew T. , Sánchez‐Sotelo, Joaquín

The Bone & Joint Journal | November 12, 2018 | Volume: 100-B | Issue: 11 | Pages: 1493-1498

10.1302/0301-620x.100b11.bjj-2018-0226.r2 Get It

Aims Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA. Patients and Methods We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10). Results Six patients (22%) developed complications requiring further revision surgery, at a mean of 1.7 years (0.1 to 5.3) postoperatively. The indication for further revision was dislocation in two, glenoid loosening in one, fracture of the humeral component in one, disassociation of the glenosphere in one, and infection in one. The five-year survival free of further revision was 85%. Five additional RSAs developed complications that did not need surgery, including dislocation in three and periprosthetic fracture in two. Overall, patients who did not require further revision had excellent pain relief, and significant improvements in elevation and external rotation of the shoulder (p < 0.01). The mean postoperative American Shoulder and Elbow Surgeons (ASES), and simple shoulder test (SST) scores were 66 and 7, respectively. Radiological results were available in 26 patients (96.3%) at a mean of 4.3 years (1.5 to 9.5). At the most recent follow-up, six patients (23%) had glenoid lucency, which were classified as grade III or higher in three (12%). Smokers had a significantly increased risk of glenoid lucency (p < 0.01). Conclusion Revision RSA, when used to salvage a failed primary RSA, can be a successful procedure. At intermediate follow-up, survival rates are reasonable, but dislocation and glenoid lucency remain a concern, particularly in smokers. Cite this article: Bone Joint J 2018;100-B:1493–98.
Revision anatomic shoulder arthroplasty with posterior capsular plication for correction of posterior instability
Wanderman, Nathan , Assenmacher, Andrew T. , Sperling, John W. , Cofield, Robert H. , Alentorn-Geli, Eduard, Wanderman, Nathan R, Sanchez-Sotelo, Joaquin, Alentorn‐Geli, Eduard , Sánchez‐Sotelo, Joaquín

Journal of Orthopaedic Surgery | July 25, 2018 | Volume: 26 | Issue: 3 | Pages: No page available

10.1177/2309499018789527 Get It

Background: Revision of failed anatomic total shoulder arthroplasty or hemiarthroplasty is a challenging procedure. Restoring adequate soft tissue balance in the revision setting can be particularly problematic. When persistent posterior instability is encountered in the revision setting, options include changing component position or size, posterior capsular plication (PCP), or conversion to a reverse arthroplasty. The purpose of this study was to report the clinical and radiographic outcomes, complications, and reoperations of PCP performed in the setting of revision anatomic shoulder arthroplasty. Patients and Methods: Between 1975 and 2013, 15 patients (16 shoulders) had PCP during revision anatomic shoulder arthroplasty. Indications for revision arthroplasty included posterior instability in 15, glenoid loosening in 3, polyethylene wear in 2, and glenoid erosion in 1 shoulder. The mean (standard deviation (SD)) age was 60.1 (12.6) years, and the median (range) follow-up was 68 (2–228) months. A retrospective chart review was conducted to obtain all data. Results: At the last follow-up, nine shoulders (56%) had absence of posterior radiographic subluxation. Five (31%) cases underwent reoperation due to persistent posterior instability. Complications were observed in seven (44%) cases. Complete pain relief was achieved in four (25%) shoulders. The mean (SD) postoperative forward flexion, external rotation, and the American Shoulder and Elbow Surgeons score were 110° (41°), 40° (29°), and 62.1 (21.9), respectively. Results were excellent in two (13%), satisfactory in seven (44%), and unsatisfactory in seven (44%) shoulders. Conclusions: PCP to correct posterior instability during revision anatomic shoulder arthroplasty had an unacceptably high failure rate. In these circumstances, consideration should instead be given to conversion to a reverse shoulder arthroplasty.
Joint contracture is reduced by intra‐articular implantation of rosiglitazone‐loaded hydrogels in a rabbit model of arthrofibrosis
Arsoy, Diren , Salib, Christopher G. , Trousdale, William H. , Tibbo, Meagan E. , Limberg, Afton K. , Lewallen, Eric A. , Reina, Nicolas , Yaszemski, Michael J. , Berry, Daniel J., Wijnen, André J. van , Berry, Daniel J. , Viste, Anthony , Reina, Nicolas , Sanchez-Sotelo, Joaquin, van Wijnen, Andre J , Berry, Daniel J , Berry, Daniel J., Morrey, Mark E. , Sánchez‐Sotelo, Joaquín , Abdel, Matthew P.

Journal of Orthopaedic Research | June 14, 2018 | Volume: 36 | Issue: 11 | Pages: 2949-2955

10.1002/jor.24068 Get It

ABSTRACTTrauma, surgery, and other inflammatory conditions can lead to debilitating joint contractures. Adjunct pharmacologic modalities may permit clinical prevention and treatment of recalcitrant joint contractures. We investigated the therapeutic potential of rosiglitazone by intra‐articular delivery via oligo[poly(ethylene glycol)fumarate] (OPF) hydrogels in an established rabbit model of arthrofibrosis. OPF hydrogels loaded with rosiglitazone were characterized for drug elution properties upon soaking in minimum essential media (MEM) with 10% fetal bovine serum and measurements of drug concentrations via High Performance Liquid Chromatography (HPLC). Drug‐loaded scaffolds were surgically implanted into 24 skeletally mature female New Zealand White rabbits that were divided into equal groups receiving OPF hydrogels loaded with rosiglitazone (1.67 mg), or vehicle control (10 µl DMSO). After 8 weeks of joint immobilization, rabbits were allowed unrestricted cage activity for 16 weeks. Contracture angles of rabbit limbs treated with rosiglitazone showed statistically significant improvements in flexion compared to control animals (mean angles, respectively, 64.4° vs. 53.3°, p < 0.03). At time of sacrifice (week 24), animals in the rosiglitazone group continued to exhibit less joint contracture than controls (119.0° vs. 99.5°, p = 0.014). The intra‐articular delivery of rosiglitazone using implanted OPF hydrogels decreases flexion contractures in a rabbit model of arthrofibrosis without causing adverse effects (e.g., gross inflammation or arthritis). Statement of Clinical Significance: Post‐traumatic joint contractures are common and debilitating, with limited available treatment options. Pharmacologic interventions can potentially prevent and treat such contractures. This study is translational in that a commercially approved medication has been repurposed through a novel delivery device. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2949–2955, 2018.
Reverse Shoulder Arthroplasty With Proximal Humeral Replacement for the Management of Massive Proximal Humeral Bone Loss
Lee, Julia , Mangold, Devin R., Cofield, Robert H. , Sperling, John W. , Shukla, Dave R. , Sánchez‐Sotelo, Joaquín

Journal of Shoulder and Elbow Arthroplasty | June 1, 2018 | Volume: 2 | Issue: No issue available | Pages: No page available

10.1177/2471549218779845 Get It

Background Substantial proximal humeral bone loss may compromise reverse shoulder arthroplasty secondary to limited implant support, insufficient soft tissue tension due to shortening, lack of attachment sites for the posterosuperior cuff when present, and lack of lateral offset of the deltoid. In these circumstances, use of a proximal humeral replacement may be considered. Patients/Methods Between 2012 and 2014, 34 consecutive reverse shoulder arthroplasties were performed using a proximal humeral replacement system. The indications were failed shoulder arthroplasty (15), oncology reconstruction (9), humeral malunion/nonunion (7), prior resection arthroplasty (2), and intraoperative fracture (1). All patients were included in the survival analysis. Twenty-two patients with minimum 2-year follow-up were included in analysis of clinical results. Results Among the cohort of 34 patients, there were 8 additional reoperations: humeral loosening (3), periprosthetic fracture (2), irrigation and debridement (2), and glenoid loosening (1). Humeral component loosening occurred exclusively in patients undergoing revision shoulder arthroplasty. The 4 patients had an average 3.75 prior procedures before the proximal humeral replacement. Two of the revisions were from cemented to uncemented stems. Among the 23 patients with minimum 2-year follow-up, there was significant improvement in pain scores (4.1 vs 0.6), forward elevation (31 vs 109) degrees, and 81% were satisfied. Conclusion Use of a proximal humeral replacement when performing a reverse shoulder arthroplasty in the complex setting of substantial proximal humerus bone loss provides good clinical results and a particularly low dislocation rate. However, the rate of loosening of the humeral component in the revision setting suggests that proximal humeral replacement components should be cemented when revising a previously cemented stem. IRB 16-006966.
Anatomic total shoulder arthroplasty with posterior capsular plication versus reverse shoulder arthroplasty in patients with biconcave glenoids: A matched cohort study
Wanderman, Nathan , Assenmacher, Andrew T. , Sperling, John W. , Cofield, Robert H. , Alentorn-Geli, Eduard, Wanderman, Nathan R, Assenmacher, Andrew T , Sanchez-Sotelo, Joaquin, Alentorn‐Geli, Eduard , Sánchez‐Sotelo, Joaquín

Journal of Orthopaedic Surgery | April 17, 2018 | Volume: 26 | Issue: 2 | Pages: No page available

10.1177/2309499018768570 Get It

Purpose: To compare the outcomes of total shoulder arthroplasty (TSA) with posterior capsule plication (PCP) and reverse shoulder arthroplasty (RSA) in patients with primary osteoarthritis, posterior subluxation, and bone loss (Walch B2). Patients and methods: All shoulders undergoing anatomic TSA with PCP were retrospectively identified (group 1, G1) and compared to shoulders undergoing RSA (group 2, G2) for Walch B2 osteoarthritis. There were 15 patients in G1 (mean (SD) age and follow-up of 70.5 (7.5) years and 42.8 (18.4) months, respectively) and 16 patients in G2 (mean (SD) age and follow-up of 72.6 (5.4) years and 35.1 (14.2) months, respectively). Results: Both groups had substantial improvements in pain and function. In G1, results were excellent in 80% and satisfactory in 20%, compared to 81% and 6% in G2, respectively ( p = 0.2). The mean (SD) American Shoulder and Elbow Surgeons score was 91.2 (6.7) and 80.3 (14.3) in G1 and G2, respectively ( p = 0.08). The mean Simple Shoulder Test score was 10.6 in G1 and 8.5 in G2 ( p = 0.01). There were no reoperations in either group, but G1 had seven postoperative complications. Conclusions: The outcomes of TSA with PCP are comparable to RSA in patients with osteoarthritis and biconcave glenoids. However, TSA leads to more complications while RSA leads to lower functional outcomes.