Back to Authors

Brinkmann, Debra H.

https://orcid.org/0000-0002-0812-3094

Mayo Clinic

Mayo Clinic

Citations 15

RTHP-02. IMPACT OF 18F-DOPA PET ON RADIOTHERAPY TARGET VOLUMES FOR NEWLY DIAGNOSED MGMT UNMETHYLATED GLIOBLASTOMA PATIENTS; PRELIMINARY RESULTS OF A PHASE II DOSE-ESCALATION TRIAL
Brinkmann, Debra H. , Pafundi, Deanna, Lowe, Val J. , Yan, Elizabeth , Brown, Paul D. , Zakhary, Mark J. , Seaberg, Maasa , Tseung, Hok Seum Wan Chan, Hunt, Christopher H. , Zhang, Yan, Sarkaria, Jann N. , Laack, Nadia N.

Neuro-Oncology | November 5, 2018 | Volume: 20 | Issue: suppl_6 | Pages: vi225-vi225

10.1093/neuonc/noy148.934 Get It

ACTR-12. PRELIMINARY SAFETY AND EFFICACY OF A PHASE II TRIAL OF 18F-DOPA PET-GUIDED, DOSE-ESCALATED RADIOTHERAPY IN THE TREATMENT OF GLIOBLASTOMA
Pafundi, Deanna, Anderson, S. Keith , Zakhary, Mark J. , Tseung, Hok Seum Wan Chan, Lowe, Val J. , Yan, Elizabeth , Kizilbash, Sani H. , Uhm, Joon H. , Hu, Leland , Brown, Paul D. , Buckner, Jan C. , Brinkmann, Debra H. , Kizilbash, Sani H , Laack, Nadia N. , Hunt, Christopher H. , Kaufmann, Timothy J. , Sarkaria, Jann N.

Neuro-Oncology | November 5, 2018 | Volume: 20 | Issue: suppl_6 | Pages: vi13-vi13

10.1093/neuonc/noy148.046 Get It

Treatment planning for metals using an extended CT number scale
Mullins, John, Herman, Michael , Brinkmann, Debra H. , Antolak, John A. , Mullins, John P, Grams, Michael P.

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 6 | Pages: 179-188

10.1120/jacmp.v17i6.6153 Get It

Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standard CT methods in the presence of high‐Z materials and artifacts, despite the reduced HU resolution of extended CT. Gafchromic film measurements were made for comparison to calculated doses. The method of direct dose calculation on extended CT scale was compared to our institution's standard method of manually contouring and assigning metal values on saturated CT images for each of the metal samples. Clinical patient plans with metal implants were investigated and DVHs were compared between standard CT and extended CT dose calculations. Dose calculations showed agreement within 2% between the two methods of metal characterization and the film measurement in the case of the strongest metal attenuator, cobalt‐chromium. In the clinical treatment plans, the greatest dose discrepancy between the two methods was 1.2%. This study suggests that direct dose calculation on an extended scale CT image in the presence of metal implants can produce accurate clinically viable treatment plans, thereby improving efficiency of clinical workflow and eliminating a potential source of human error by manual CT number assignment.PACS number(s): 87.55.dk
MRI in radiation oncology: Underserved needs
McGee, Kiaran P. , Hu, Yanle , Tryggestad, E., Brinkmann, Debra H. , Witte, Bob, Welker, Kirk M. , Panda, Anshuman , Haddock, Michael G. , Bernstein, Matt A. , Tryggestad, Erik, Brinkmann, Debra, Welker, Kirk, Haddock, Michael, Bernstein, Matt A

Magnetic Resonance in Medicine | July 14, 2015 | Volume: 75 | Issue: 1 | Pages: 11-14

10.1002/mrm.25826 Get It

An investigation of temporal resolution parameters in cine‐mode four‐dimensional computed tomography acquisition
Mutaf, Y. D., Brinkmann, Debra H.

Journal of Applied Clinical Medical Physics | December 10, 2008 | Volume: 9 | Issue: 4 | Pages: 172-180

10.1120/jacmp.v9i4.2819 Get It

The accuracy of four‐dimensional computed tomography (4DCT) imaging depends on temporal characteristics of the acquisition protocol—for example, the temporal spacing of the reconstructed images (also known as cine duration between images) and the gantry rotation speed. These parameters affect the temporal resolution of 4DCT images, and a single default acquisition protocol, as commonly used in most clinics, may be suboptimal for a subset of respiratory motion characteristics. It could lead to substantial inaccuracies in target delineation. The aim of the present study was to evaluate the interplay between parameters affecting temporal resolution and the accuracy of the resulting images.We acquired 4DCT images of cylindrical phantoms under repetitive motion induced by a translation platform. Acquisition settings varied with respect to temporal spacing, gantry rotation speed, and motion period of the phantoms. Reconstructed images were sorted into 10 phase bins and were compared to static phantom images acquired at corresponding positions of the respiration phase. Acquisitions with different temporal spacing did not play a significant role in the amount of motion observed in full‐cycle maximum intensity projection images. Target delineation accuracy at end‐of‐inhalation phase was observed to be constant up to a threshold in the value of the reconstruction interval, beyond which it varied arbitrarily. This threshold was found to be correlated with the number of phase bins and the motion period. No observable variations were noted with images from the end of exhalation when temporal spacing was varied. Target delineation accuracy was observed to be enhanced in acquisitions using faster gantry rotation speeds. An evaluation of the acquisition parameters needs to be performed depending on the period of the motion and limiting factors such as the availability of acquisition settings, X‐ray tube workload, image storage, and processing power.PACS numbers: 87.53.Xd, 87.57.‐s, 87.57.Gg, 87.59.Fm