Abstract Background: Mammographic breast density declines during menopause. We assessed changes in volumetric breast density across the menopausal transition and factors that influence these changes. Methods: Women without a history of breast cancer, who had full field digital mammograms during both pre- and postmenopausal periods, at least 2 years apart, were sampled from four facilities within the San Francisco Mammography Registry from 2007 to 2013. Dense breast volume (DV) was assessed using Volpara on mammograms across the time period. Annualized change in DV from pre- to postmenopause was estimated using linear mixed models adjusted for covariates and per-woman random effects. Multiplicative interactions were evaluated between premenopausal risk factors and time to determine whether these covariates modified the annualized changes. Results: Among the 2,586 eligible women, 1,802 had one premenopausal and one postmenopausal mammogram, 628 had an additional perimenopausal mammogram, and 156 had two perimenopausal mammograms. Women experienced an annualized decrease in DV [−2.2 cm3 (95% confidence interval, −2.7 to −1.7)] over the menopausal transition. Declines were greater among women with a premenopausal DV above the median (54 cm3) versus below (DV, −3.5 cm3 vs. −1.0 cm3; P < 0.0001). Other breast cancer risk factors, including race, body mass index, family history, alcohol, and postmenopausal hormone therapy, had no effect on change in DV over the menopausal transition. Conclusions: High premenopausal DV was a strong predictor of greater reductions in DV across the menopausal transition. Impact: We found that few factors other than premenopausal density influence changes in DV across the menopausal transition, limiting targeted prevention efforts.
Dense and Nondense Mammographic Area and Risk of Breast Cancer by Age and Tumor Characteristics
Abstract Breast density is a strong risk factor for breast cancer; however, no standard assessment method exists. An automated breast density method was modified and compared with a semi-automated, user-assisted thresholding method (Cumulus method) and the Breast Imaging Reporting and Data System four-category tissue composition measure for their ability to predict future breast cancer risk. The three estimation methods were evaluated in a matched breast cancer case-control (n = 372 and n = 713, respectively) study at the Mayo Clinic using digitized film mammograms. Mammograms from the craniocaudal view of the noncancerous breast were acquired on average 7 years before diagnosis. Two controls with no previous history of breast cancer from the screening practice were matched to each case on age, number of previous screening mammograms, final screening exam date, menopausal status at this date, interval between earliest and latest available mammograms, and residence. Both Pearson linear correlation (R) and Spearman rank correlation (r) coefficients were used for comparing the three methods as appropriate. Conditional logistic regression was used to estimate the risk for breast cancer (odds ratios and 95% confidence intervals) associated with the quartiles of percent breast density (automated breast density method, Cumulus method) or Breast Imaging Reporting and Data System categories. The area under the receiver operator characteristic curve was estimated and used to compare the discriminatory capabilities of each approach. The continuous measures (automated breast density method and Cumulus method) were highly correlated with each other (R = 0.70) but less with Breast Imaging Reporting and Data System (r = 0.49 for automated breast density method and r = 0.57 for Cumulus method). Risk estimates associated with the lowest to highest quartiles of automated breast density method were greater in magnitude [odds ratios: 1.0 (reference), 2.3, 3.0, 5.2; P trend < 0.001] than the corresponding quartiles for the Cumulus method [odds ratios: 1.0 (reference), 1.7, 2.1, and 3.8; P trend < 0.001] and Breast Imaging Reporting and Data System [odds ratios: 1.0 (reference), 1.6, 1.5, 2.6; P trend < 0.001] method. However, all methods similarly discriminated between case and control status; areas under the receiver operator characteristic curve were 0.64, 0.63, and 0.61 for automated breast density method, Cumulus method, and Breast Imaging Reporting and Data System, respectively. The automated breast density method is a viable option for quantitatively assessing breast density from digitized film mammograms. (Cancer Epidemiol Biomarkers Prev 2008;17(11):3090–7)