Fourteen single-sided deaf listeners fit with an MED-EL cochlear implant (CI) judged the similarity of clean signals presented to their CI and modified signals presented to their normal-hearing ear. The signals to the normal-hearing ear were created by (a) filtering, (b) spectral smearing, (c) changing overall fundamental frequency (F0), (d) F0 contour flattening, (e) changing formant frequencies, (f) altering resonances and ring times to create a metallic sound quality, (g) using a noise vocoder, or (h) using a sine vocoder. The operations could be used singly or in any combination. On a scale of 1 to 10 where 10 was a complete match to the sound of the CI, the mean match score was 8.8. Over half of the matches were 9.0 or higher. The most common alterations to a clean signal were band-pass or low-pass filtering, spectral peak smearing, and F0 contour flattening. On average, 3.4 operations were used to create a match. Upshifts in formant frequencies were implemented most often for electrode insertion angles less than approximately 500°. A relatively small set of operations can produce signals that approximate the sound of the MED-EL CI. There are large individual differences in the combination of operations needed. The sound files in Supplemental Material approximate the sound of the MED-EL CI for patients fit with 28-mm electrode arrays.
Hearing preservation surgery: Psychophysical estimates of cochlear damage in recipients of a short electrode array
In the newest implementation of cochlear implant surgery, electrode arrays of 10 or 20mm are inserted into the cochlea with the aim of preserving hearing in the region apical to the tip of the electrode array. In the current study two measures were used to assess hearing preservation: changes in audiometric threshold and changes in psychophysical estimates of nonlinear cochlear processing. Nonlinear cochlear processing was evaluated at signal frequencies of 250 and 500Hz using Schroeder phase maskers with various indices of masker phase curvature. A total of 15 normal-hearing listeners and 13 cochlear implant patients (7 with a 10mm insertion and 6 with a 20mm insertion) were tested. Following surgery the mean low-frequency threshold elevation was 12.7dB (125–750Hz). Nine patients had postimplant thresholds within 5–10dB of preimplant thresholds. Only one patient, however, demonstrated a completely normal nonlinear cochlear function following surgery—although most retained some degree of residual nonlinear processing. This result indicates (i) that Schroeder phase masking functions are a more sensitive index of surgical trauma than audiometric threshold and (ii) that preservation of a normal cochlear function in the apex of the cochlea is relatively uncommon but possible.