Approximations to the Voice of a Cochlear Implant: Explorations With Single-Sided Deaf Listeners
Dorman, Michael F. , Natale, Sarah Cook, Baxter, Leslie C. , Zeitler, Daniel M. , Carlson, Matthew L. , Lorens, Artur , Skarżyńśki, Henryk , Peters, Jeroen P. M. , Torres, Jennifer H., Noble, Jack H. , Baxter, Leslie C.

Trends in Hearing | April 27, 2020 | Volume: 24 | Issue: No issue available | Pages: No page available

10.1177/2331216520920079 Get It

Fourteen single-sided deaf listeners fit with an MED-EL cochlear implant (CI) judged the similarity of clean signals presented to their CI and modified signals presented to their normal-hearing ear. The signals to the normal-hearing ear were created by (a) filtering, (b) spectral smearing, (c) changing overall fundamental frequency (F0), (d) F0 contour flattening, (e) changing formant frequencies, (f) altering resonances and ring times to create a metallic sound quality, (g) using a noise vocoder, or (h) using a sine vocoder. The operations could be used singly or in any combination. On a scale of 1 to 10 where 10 was a complete match to the sound of the CI, the mean match score was 8.8. Over half of the matches were 9.0 or higher. The most common alterations to a clean signal were band-pass or low-pass filtering, spectral peak smearing, and F0 contour flattening. On average, 3.4 operations were used to create a match. Upshifts in formant frequencies were implemented most often for electrode insertion angles less than approximately 500°. A relatively small set of operations can produce signals that approximate the sound of the MED-EL CI. There are large individual differences in the combination of operations needed. The sound files in Supplemental Material approximate the sound of the MED-EL CI for patients fit with 28-mm electrode arrays.
The Sound Quality of Cochlear Implants: Studies With Single-sided Deaf Patients
Dorman, Michael F. , Natale, Sarah Cook, Butts, Austin McRae, Zeitler, Daniel M. , Carlson, Matthew L.

Otology & Neurotology | August 12, 2017 | Volume: 38 | Issue: 8 | Pages: e268-e273

10.1097/mao.0000000000001449 Get It

Objective: The goal of the present study was to assess the sound quality of a cochlear implant for single-sided deaf (SSD) patients fit with a cochlear implant (CI). Background: One of the fundamental, unanswered questions in CI research is “what does an implant sound like?” Conventional CI patients must use the memory of a clean signal, often decades old, to judge the sound quality of their CIs. In contrast, SSD-CI patients can rate the similarity of a clean signal presented to the CI ear and candidate, CI-like signals presented to the ear with normal hearing. Methods: For Experiment 1 four types of stimuli were created for presentation to the normal hearing ear: noise vocoded signals, sine vocoded signals, frequency shifted, sine vocoded signals and band-pass filtered, natural speech signals. Listeners rated the similarity of these signals to unmodified signals sent to the CI on a scale of 0 to 10 with 10 being a complete match to the CI signal. For Experiment 2 multitrack signal mixing was used to create natural speech signals that varied along multiple dimensions. Results: In Experiment 1 for eight adult SSD-CI listeners, the best median similarity rating to the sound of the CI for noise vocoded signals was 1.9; for sine vocoded signals 2.9; for frequency upshifted signals, 1.9; and for band pass filtered signals, 5.5. In Experiment 2 for three young listeners, combinations of band pass filtering and spectral smearing lead to ratings of 10. Conclusion: The sound quality of noise and sine vocoders does not generally correspond to the sound quality of cochlear implants fit to SSD patients. Our preliminary conclusion is that natural speech signals that have been muffled to one degree or another by band pass filtering and/or spectral smearing provide a close, but incomplete, match to CI sound quality for some patients.
Hearing preservation surgery: Psychophysical estimates of cochlear damage in recipients of a short electrode array
Gifford, René H. , Dorman, Michael F. , Spahr, Anthony J., Bacon, Sid P., Skarżyńśki, Henryk , Lorens, Artur

The Journal of the Acoustical Society of America | October 15, 2008 | Volume: 124 | Issue: 4 | Pages: 2164-2173

10.1121/1.2967842 Get It

In the newest implementation of cochlear implant surgery, electrode arrays of 10 or 20mm are inserted into the cochlea with the aim of preserving hearing in the region apical to the tip of the electrode array. In the current study two measures were used to assess hearing preservation: changes in audiometric threshold and changes in psychophysical estimates of nonlinear cochlear processing. Nonlinear cochlear processing was evaluated at signal frequencies of 250 and 500Hz using Schroeder phase maskers with various indices of masker phase curvature. A total of 15 normal-hearing listeners and 13 cochlear implant patients (7 with a 10mm insertion and 6 with a 20mm insertion) were tested. Following surgery the mean low-frequency threshold elevation was 12.7dB (125–750Hz). Nine patients had postimplant thresholds within 5–10dB of preimplant thresholds. Only one patient, however, demonstrated a completely normal nonlinear cochlear function following surgery—although most retained some degree of residual nonlinear processing. This result indicates (i) that Schroeder phase masking functions are a more sensitive index of surgical trauma than audiometric threshold and (ii) that preservation of a normal cochlear function in the apex of the cochlea is relatively uncommon but possible.