AbstractObjectiveThis study sought to determine if single‐chamber operation and/or loss of rate response (RR) during elective replacement indicator (ERI) in patients with dual‐chamber pacemakers lead to increased symptom burden, healthcare utilization, and atrial fibrillation (AF).BackgroundDual‐chamber pacemakers often change from dual‐ to single‐chamber pacing mode and/or lose RR functionality at ERI to preserve battery. Single‐chamber pacing increases the incidence of heart failure, AF, and pacemaker syndrome suggesting these changes may be deleterious.MethodsA retrospective analysis of 700 patients was completed. Three comparisons were analyzed: Comparison 1: mode change and RR loss versus no change; Comparison 2: RR loss only versus no change; Comparison 3: mode change only versus no change (in patients with no RR programmed at baseline).ResultsIn Comparison 1, 121 (46%) patients with setting changes experienced symptoms (most often dyspnea and fatigue/exercise intolerance) versus 3 (4%) without setting changes (p < .0001). Similar results were noted in Comparisons 2 and 3 (p = .0016 and p = .0001, respectively). In Comparison 1, patients with setting change sought provider contact more than patients without setting changes (p = .0001). A significant difference was not noted in Comparison 2 or 3. Overall 14 (2%) patients were hospitalized, all of whom had setting changes.ConclusionsSetting changes at ERI including a change from dual‐ to single‐chamber pacing and/or loss of RR results in a significantly increased symptom burden and increased healthcare utilization.
Fibroplasty (venoplasty) to facilitate transvenous lead placement: A single‐center experience
AbstractIntroductionVenous stenosis is a well‐recognized complication of transvenous leads (TVLs) that is encountered during lead revisions or device upgrades. We here report the outcomes of TVL placement facilitated by fibroplasty or tunneling (TUN) procedure.MethodsWe conducted a single‐center retrospective cohort study of all patients undergoing TVL implantation requiring fibroplasty or TUN from 2005 to 2017. Medical records and procedure reports were reviewed for relevant data. Outcomes for fibroplasty and TUN to facilitate TVL placement were compared.ResultsSixty patients had fibroplasty and thirty‐five patients had a TUN procedure. There was no difference in procedure success rates between the two groups (97% fibroplasty vs. 100% TUN; p = .98). The fluoroscopy time was longer (fibroplasty = 39.7 ± 21.5 min vs. TUN = 29.2 ± 21.3 min; p = .01) and the total procedural time was shorter in the fibroplasty group (fibroplasty = 247 ± 77.8 min vs. TUN = 287 ± 77.1 min; p = .01). TUN was associated with a significantly higher incidence of acute complications (fibroplasty = 0 vs. TUN = 8; p = .002) most requiring invasive intervention and/or transfusion with blood products. Long‐term complications requiring additional device‐related procedures were comparable between the two groups (fibroplasty = 6 vs. TUN = 6; logrank p = .21).ConclusionsFor patients with venous stenosis requiring additional TVL, balloon fibroplasty is associated with similar rates of success and a significantly decreased incidence of acute complications when compared with subcutaneous TUN.
Artificial Intelligence and Machine Learning in Arrhythmias and Cardiac Electrophysiology
Artificial intelligence (AI) and machine learning (ML) in medicine are currently areas of intense exploration, showing potential to automate human tasks and even perform tasks beyond human capabilities. Literacy and understanding of AI/ML methods are becoming increasingly important to researchers and clinicians. The first objective of this review is to provide the novice reader with literacy of AI/ML methods and provide a foundation for how one might conduct an ML study. We provide a technical overview of some of the most commonly used terms, techniques, and challenges in AI/ML studies, with reference to recent studies in cardiac electrophysiology to illustrate key points. The second objective of this review is to use examples from recent literature to discuss how AI and ML are changing clinical practice and research in cardiac electrophysiology, with emphasis on disease detection and diagnosis, prediction of patient outcomes, and novel characterization of disease. The final objective is to highlight important considerations and challenges for appropriate validation, adoption, and deployment of AI technologies into clinical practice.
Risk of QTc prolongation among cancer patients treated with tyrosine kinase inhibitors
AbstractQTc interval prolongation can lead to life‐threatening complications such as Torsade de Pointes (TdP), ventricular tachycardia (VT) and sudden cardiac death (SCD). It can occur with tyrosine kinase inhibitors (TKIs) but comparative real‐world analyses on the incidence and complication rates are scarce. We retrospectively reviewed all cancer patients treated with TKI therapy at Mayo Clinic between January 2005 and December 2018 and had at least two ECGs (before and after TKI). For each TKI type, we determined the administration rate and incidence of QTc prolongation. QTc prolongation was defined as a corrected QT interval (by Fridericia formula) ≥450 ms in men and ≥470 ms in women. A total of 618 cancer patients were included with 902 TKI administrations, of which 654 (72.5%) were accounted for by pazopanib, sunitinib, imatinib, nilotinib and dasatinib. QTc prolongation (any grade) was reported in 28.8%, most commonly with nilotinib (38.7%) and dasatinib (41.7%). A QTc interval ≥500 ms and a QTc increase ≥60 ms was documented in 46 and 63 administrations, respectively. Life‐threatening toxicity was seen in 14 cases (5.4% of QTc prolongation cases) including VT in 9, SCD in 3 and TdP in two administrations. The response to QTc prolongation was: discontinuation in 68%, dose reduction in 13.5%, temporary hold in 8.1% and no action in 10.4%. In conclusion, QTc prolongation with TKI therapy is very common (∼1/3 of cases) and in 5% (1.7% overall) associated with life‐threatening complications. These data support recommendations for careful ECG monitoring in cancer patients undergoing TKI therapy.
Artificial intelligence-enabled electrocardiogram: can we identify patients with unrecognized atrial fibrillation?
Background: Deep learning algorithms derived in homogeneous populations may be poorly generalizable and have the potential to reflect, perpetuate, and even exacerbate racial/ethnic disparities in health and health care. In this study, we aimed to (1) assess whether the performance of a deep learning algorithm designed to detect low left ventricular ejection fraction using the 12-lead ECG varies by race/ethnicity and to (2) determine whether its performance is determined by the derivation population or by racial variation in the ECG. Methods: We performed a retrospective cohort analysis that included 97 829 patients with paired ECGs and echocardiograms. We tested the model performance by race/ethnicity for convolutional neural network designed to identify patients with a left ventricular ejection fraction ≤35% from the 12-lead ECG. Results: The convolutional neural network that was previously derived in a homogeneous population (derivation cohort, n=44 959; 96.2% non-Hispanic white) demonstrated consistent performance to detect low left ventricular ejection fraction across a range of racial/ethnic subgroups in a separate testing cohort (n=52 870): non-Hispanic white (n=44 524; area under the curve [AUC], 0.931), Asian (n=557; AUC, 0.961), black/African American (n=651; AUC, 0.937), Hispanic/Latino (n=331; AUC, 0.937), and American Indian/Native Alaskan (n=223; AUC, 0.938). In secondary analyses, a separate neural network was able to discern racial subgroup category (black/African American [AUC, 0.84], and white, non-Hispanic [AUC, 0.76] in a 5-class classifier), and a network trained only in non-Hispanic whites from the original derivation cohort performed similarly well across a range of racial/ethnic subgroups in the testing cohort with an AUC of at least 0.930 in all racial/ethnic subgroups. Conclusions: Our study demonstrates that while ECG characteristics vary by race, this did not impact the ability of a convolutional neural network to predict low left ventricular ejection fraction from the ECG. We recommend reporting of performance among diverse ethnic, racial, age, and sex groups for all new artificial intelligence tools to ensure responsible use of artificial intelligence in medicine.
Left sinus of Valsalva—Electroanatomic basis and outcomes with ablation for outflow tract arrhythmias
AbstractIntroductionThe ablation of outflow tract premature ventricular contractions (PVCs) is generally safe and effective. In some patients, successful ablation sites may not correlate with the earliest activation. We sought to evaluate mechanistic and anatomic relevance of the region below the left sinus of Valsalva in variable morphology outflow tract ventricular arrhythmias.MethodsPVC cases where ablation was in the region inferior to the left sinus of Valsalva were identified. Procedural and demographic information and long‐term outcomes were obtained. Cadaver dissections to evaluate regional anatomy were done as well.ResultsA total of 51 cases were included (age 53 ± 10; 37 [73%] males). Ablation was done for high PVC burden (>20%; mean 27% ± 8%) and presence of symptoms (73%) or ejection fraction less than 50% (78%). QRS morphology included either R wave (8; 16%), Rs (9; 18%), or rS (67%) in lead I, no precordial transition (40; 78%), V2 transition, (7; 14%), or V3 transition (4; 8%). In 31 (61%), the site just below the left coronary cusp was the earliest site, while the remainder had another site earlier. Ablation was acutely successful in 50 of 51 (98%). After 3 months, success was noted in 48 of 51 (94%). In two patients, repeat ablation in the same region resulted in durable suppression.ConclusionThe cases presented emphasize the importance of a region centered below the left sinus of Valsalva, where multivariable morphology QRS may be successfully ablated. Consideration of mapping and ablation even when signals are late in this region may be warranted in previously failed ablation attempts or first‐line evaluation.
Utility of 30-Day Continuous Ambulatory Monitoring to Identify Patients With Delayed Occurrence of Atrioventricular Block After Transcatheter Aortic Valve Replacement
Background: Mechanical injury in the conduction system requiring permanent pacemaker (PPM) associated with transcatheter aortic valve replacement (TAVR) procedure is a common complication. The objective of this study was to use ambulatory monitor BodyGuardian to assess late occurrence of atrioventricular block (AVB) after TAVR. Methods: This prospective study evaluated 365 patients who underwent TAVR at Mayo Clinic, Rochester, Minnesota between June 2016 and August 2017. Patients who received PPM for bradycardia after TAVR before discharge were considered as the PPM group. Those not requiring PPM received a BodyGuardian system (BodyGuardian group) for 30 days of continuous monitoring. Primary end point was Mobitz II or third-degree atrioventricular block (II/III AVB) at 30-day follow-up. Results: Of 365 patients, 74 who had a PPM or an implantable cardioverter-defibrillator before TAVR and 94 who were enrolled in other studies were excluded. Of 197 patients enrolled in the study, 70 (35.5%) received PPM and 127 had BodyGuardian before the hospital dismissal. Eleven of 127 (8.6%) BodyGuardian group required PPM within 30 days after TAVR for late occurrence of symptomatic bradycardia. In total, 33 of 197 (16.7%) patients developed II/III AVB (24 before and 9 after discharge). Thirty-four patients had preexisting right bundle branch block. Of them, 16 (47%) developed II/III AVB. Of 53 patients who developed new left bundle branch block after TAVR, 14% progressed to II/III AVB within 30 days. Conclusions: In patients without a standard post-TAVR pacing indication, yet a potential risk to develop AVB, a strategy of 30-day monitoring identifies additional patients who require permanent pacing.
Injectable Flexible Subcutaneous Electrode Array Technology for Electrocardiogram Monitoring Device
Abstract Background Venous stenosis is a well-recognized complication of transvenous leads when patients require lead revisions or device upgrade. In these cases, balloon venoplasty or alternative venous access with subcutaneous tunneling can be performed. Purpose Compare the outcomes of venoplasty vs. tunneling in patients requiring additional transvenous lead implantation. Methods A single center retrospective cohort study of all patients undergoing lead implantation/revision requiring venoplasty or tunneling from 2005–2017. Chi-squared and Wilcoxon Rank-Sum tests were used to compare categorical and continuous variables. Results Ninety five patients met our inclusion criteria (60 venoplasty & 35 tunneling). There was no difference in procedure success rates (p-value=0.98). Tunneling was associated with less fluoroscopy time but higher incidence of acute complications (0% vs. 23%, p-value=0.002) most requiring invasive intervention and/or blood product transfusion. Long term outcomes were comparable and related to lead failure or infection. Outcomes for tunneling vs. venoplasty Variable Tunneling (n=35) Venoplasty (n=60) p-value Age Y 67 (23–84) 70 (29–91) 0.25 Male (%) 24 (69%) 41 (68%) 0.98 Number of existing leads 2.1 (1–4) 2.4 (0–4) 0.1 Age of oldest lead 7.0 (0–21) 7.2 (0–33) 0.73 Number of new leads 1.2 (1–3) 1.4 (1–3) 0.26 Fluoroscopy time (SD) min 29.2 (21.3) 39.7 (21.5) 0.012 Procedure success (%) 35 (100%) 55 (92%) 0.9 Acute complications (%) 8 (23%)1 0 (0%) 0.0002 Pocket hematoma/bleed 4 (11%)2 Hemothorax 2 (6%)3 Pericarditis 1 (3%) Lead compromise 1 (3%) Follow up M 18 (0–76) 28 (0–98) N/A Long term lead issues (%) 6 (17%) 10 (17%) 0.95 Long term complication requiring intervention 4 (11%) 8 (13%) N/A Procedure success: functional lead placed as a result of venoplasty or tunneling. 1Two patients required blood products. 2Two patients required invasive intervention. 3One patient required chest tube and the other ICU admission. Conclusions Balloon venoplasty is associated with similar rates of success and a less incidence of acute complications when compared subcutaneous tunneling. Acknowledgement/Funding NIH T32 Training Grant HL07111-40