Back to Authors

Stead, S. Matthew

Mayo Clinic

Mayo Clinic

Citations 4

Gamma oscillations precede interictal epileptiform spikes in the seizure onset zone
Ren, Liankun , Kucewicz, Michał T. , Cimbálník, Jan , Matsumoto, Joseph Y., Brinkmann, Benjamin H. , Hu, Wei , Marsh, W. Richard , Meyer, Fredric B. , Stead, S. Matthew, Worrell, Gregory A. , Brinkmann, Benjamin H , Kucewicz, Michal

Neurology | January 14, 2015 | Volume: 84 | Issue: 6 | Pages: 602-608

10.1212/wnl.0000000000001234 Get It

Pathological and physiological high-frequency oscillations in focal human epilepsy
Matsumoto, Andrew , Brinkmann, Benjamin H. , Stead, S. Matthew, Matsumoto, Joseph Y., Kucewicz, Michał T. , Marsh, W. Richard , Meyer, Frederic B., Worrell, Gregory A. , Brinkmann, Benjamin H , Kucewicz, Michal

Journal of Neurophysiology | August 7, 2013 | Volume: 110 | Issue: 8 | Pages: 1958-1964

10.1152/jn.00341.2013 Get It

High-frequency oscillations (HFO; gamma: 40–100 Hz, ripples: 100–200 Hz, and fast ripples: 250–500 Hz) have been widely studied in health and disease. These phenomena may serve as biomarkers for epileptic brain; however, a means of differentiating between pathological and normal physiological HFO is essential. We categorized task-induced physiological HFO during periods of HFO induced by a visual or motor task by measuring frequency, duration, and spectral amplitude of each event in single trial time-frequency spectra and compared them to pathological HFO similarly measured. Pathological HFO had higher mean spectral amplitude, longer mean duration, and lower mean frequency than physiological-induced HFO. In individual patients, support vector machine analysis correctly classified pathological HFO with sensitivities ranging from 70–98% and specificities >90% in all but one patient. In this patient, infrequent high-amplitude HFO were observed in the motor cortex just before movement onset in the motor task. This finding raises the possibility that in epileptic brain physiological-induced gamma can assume higher spectral amplitudes similar to those seen in pathologic HFO. This method if automated and validated could provide a step towards differentiating physiological HFO from pathological HFO and improving localization of epileptogenic brain.
Intracranial electroencephalography seizure onset patterns and surgical outcomes in nonlesional extratemporal epilepsy
Wetjen, Nicholas M. , Marsh, W. Richard , Meyer, Fredric B. , Cascino, Gregory D. , So, Elson, Stead, S. Matthew, So, Elson L., Britton, Jeffrey W. , Worrell, Gregory A.

Journal of Neurosurgery | December 12, 2008 | Volume: 110 | Issue: 6 | Pages: 1147-1152

10.3171/2008.8.jns17643 Get It

Object Patients with normal MR imaging (nonlesional) findings and medically refractory extratemporal epilepsy make up a disproportionate number of nonexcellent outcomes after epilepsy surgery. In this paper, the authors investigated the usefulness of intracranial electroencephalography (iEEG) in the identification of surgical candidates. Methods Between 1992 and 2002, 51 consecutive patients with normal MR imaging findings and extratemporal epilepsy underwent intracranial electrode monitoring. The implantation of intracranial electrodes was determined by seizure semiology, interictal and ictal scalp EEG, SPECT, and in some patients PET studies. The demographics of patients at the time of surgery, lobar localization of electrode implantation, duration of follow-up, and Engel outcome score were abstracted from the Mayo Rochester Epilepsy Surgery Database. A blinded independent review of the iEEG records was conducted for this study. Results Thirty-one (61%) of the 51 patients who underwent iEEG ultimately underwent resection for their epilepsy. For 28 (90.3%) of the 31 patients who had epilepsy surgery, adequate information regarding follow-up (> 1 year), seizure frequency, and iEEG recordings was available. Twenty-six (92.9%) of 28 patients had frontal lobe resections, and 2 had parietal lobe resections. The most common iEEG pattern at seizure onset in the surgically treated group was a focal high-frequency discharge (in 15 [53.6%] of 28 patients). Ten (35.7%) of the 28 surgically treated patients were seizure free. Fourteen (50%) had Engel Class I outcomes, and overall, 17 (60.7%) had significant improvement (Engel Class I and IIAB with ≥80% seizure reduction). Focal high-frequency oscillation at seizure onset was associated with Engel Class I surgical outcome (12 [85.7%] of 14 patients, p = 0.02), and it was uncommon in the nonexcellent outcome group (3 [21.4%] of 14 patients). Conclusions A focal high-frequency oscillation (> 20 Hz) at seizure onset on iEEG may identify patients with nonlesional extratemporal epilepsy who are likely to have an Engel Class I outcome after epilepsy surgery. The prospect of excellent outcome in nonlesional extratemporal lobe epilepsy prior to intracranial monitoring is poor (14 [27.5%] of 51 patients). However, iEEG can further stratify patients and help identify those with a greater likelihood of Engel Class I outcome after surgery.
Phase I trial: safety and feasibility of intracranial electroencephalography using hybrid subdural electrodes containing macro- and microelectrode arrays
Stead, S. Matthew, Meyer, Fredric B. , Marsh, W. Richard , Fountain, Todd, So, Elson, Cohen‐Gadol, Aaron , Lee, Kendall H. , Gompel, Jamie J. Van , Giannini, Caterina , So, Elson L., Worrell, Gregory A.

Neurosurgical Focus | August 29, 2008 | Volume: 25 | Issue: 3 | Pages: E23

10.3171/foc/2008/25/9/e23 Get It

Object Cerebral cortex electrophysiology is poorly sampled using standard, low spatial resolution clinical intracranial electrodes. Adding microelectrode arrays to the standard clinical macroelectrode arrays increases the spatial resolution and may ultimately improve the clinical utility of intracranial electroencephalography (iEEG). However, the safety of hybrid electrode systems containing standard clinical macroelectrode and microelectrode arrays is not yet known. The authors report on their preliminary experience in 24 patients who underwent implantation of hybrid electrodes. Methods In this study, 24 consecutive patients underwent long-term iEEG monitoring with implanted hybrid depth and subdural grid and strip electrodes; both clinical macroelectrodes and research microelectrodes were used. The patients included 18 women and 6 men with an average age of 35 ± 12 years (range 21–65). The mean hospital stay was 11 ± 4 days (range 5–20), with mean duration of implantation 7.0 ± 3.2 days (range 3–15). Data from the 198 consecutive craniotomies for standard clinical subdural grid insertion (prior to surgery in the 24 patients described here) were used for comparison to investigate the relative risk of complications. Results Focal seizure identification and subsequent resection was performed in 20 patients. One patient underwent a subsequent operation after neurological deterioration secondary to cerebral swelling and a 5-mm subdural hematoma. There were no infections. The overall complication rate was 4.2% (only 1 patient had a complication), which did not significantly differ from the complication rate previously reported by the authors of 6.6% when standard subdural and depth intracranial electrodes were used. There were no deaths or permanent neurological deficits related to electrode implantation. Conclusions The authors demonstrate the use of hybrid subdural strip and grid electrodes containing high-density microwire arrays and standard clinical macroelectrodes. Hybrid electrodes provide high spatial resolution electrophysiology of the neocortex that is impossible with standard clinical iEEG. In this initial study in 24 patients, the complication rate is acceptable, and there does not appear to be increased risk associated with the use of hybrid electrodes compared with standard subdural and depth iEEG electrodes. More research is required to show whether hybrid electrode recordings will improve localization of epileptic foci and tracking the generation of neocortical seizures.