Back to Authors

Ellenbogen, Kenneth A.

https://orcid.org/0000-0002-8527-569X

Mayo Clinic

Australian National University

Citations 14

Troubleshooting Implantable Cardioverter-Defibrillator Sensing Problems II
Swerdlow, Charles D. , Asirvatham, Samuel J. , Ellenbogen, Kenneth A. , Friedman, Paul A. , Asirvatham, Samuel J , Ellenbogen, Kenneth A

Circulation: Arrhythmia and Electrophysiology | February 17, 2015 | Volume: 8 | Issue: 1 | Pages: 212-220

10.1161/circep.114.002514 Get It

Troubleshooting Implanted Cardioverter Defibrillator Sensing Problems I
Swerdlow, Charles D. , Asirvatham, Samuel J. , Ellenbogen, Kenneth A. , Friedman, Paul A. , Asirvatham, Samuel J , Ellenbogen, Kenneth A

Circulation: Arrhythmia and Electrophysiology | December 16, 2014 | Volume: 7 | Issue: 6 | Pages: 1237-1261

10.1161/circep.114.002344 Get It

Atrioventricular Nodal Ablation in Atrial Fibrillation: A Meta-Analysis of Biventricular vs. Right Ventricular Pacing Mode
Upadhyay, Gaurav A. , Ellenbogen, Kenneth A. , Hayes, David L. , Chatterjee, Neal A. , Ng, G. André , Ellenbogen, Kenneth A

European Journal of Heart Failure | March 22, 2012 | Volume: 14 | Issue: 6 | Pages: 661-667

10.1093/eurjhf/hfs036 Get It

Abstract Aims For patients with refractory atrial fibrillation (AF) undergoing atrioventricular nodal ablation (AVNA), initial single-chamber right ventricular (RV)-only pacing is standard. Given the deleterious effects of chronic RV-only pacing, the impact of an initial biventricular (BiV) pacing strategy post-ablation is of interest. Methods and results We conducted a meta-analysis to determine the effect of BiV vs. RV-only pacing in patients undergoing AVNA for refractory atrial fibrillation. A search of multiple electronic databases identified 921 reports, which included four randomized controlled trials (n = 534). Mean New York Heart Association (NYHA) class was 2.3 and mean left ventricular ejection fraction (LVEF) was 44%. When compared with RV-only pacing, BiV pacing was not associated with reduced mortality [risk ratio 0.85, 95% confidence interval (CI) 0.40–1.82, P = 0.68]. In three studies comprised of patients with left ventricular systolic dysfunction (mean EF 41 ± 3%), BiV pacing demonstrated a non-significant reduction in cardiac mortality (risk ratio 0.59, 95% CI 0.25–1.39; P = 0.23). Compared with RV-only pacing, BiV pacing was associated with significant improvement in symptoms [Minnesota Living with Heart Failure Questionnaire (MLWHFQ) 2.72 points fewer, 95% CI 1.45–3.99] and increased LVEF (+2.6%, 95% CI 1.69–3.44), but no significant change in 6 min walk distance (6MWD) (5.02 ms more, 95% CI −1.56 to 11.59; P = 0.13). Conclusions In patients with refractory AF undergoing AVNA, BiV pacing was not associated with significantly improved survival when compared with RV-only pacing. A modest, but significant improvement in structural and functional response to BiV pacing was observed.
HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): Description of Techniques, Indications, Personnel, Frequency and Ethical Considerations
Wilkoff, Bruce L. , Brugada, Josép , Cowie, Martín , Ellenbogen, Kenneth A. , Gillis, Anne M. , Hayes, David L. , Howlett, Jonathan G. , Kautzner, Josef , Love, Charles J. , Morgan, John , Reynolds, Dwight, Schoenfeld, Mark H., Auricchio, Angelo , Priori, Silvia G. , Vardas, Panos , Cowie, Martin R , Ellenbogen, Kenneth A

Europace | May 14, 2008 | Volume: 10 | Issue: 6 | Pages: 707-725

10.1093/europace/eun122 Get It