The surface roughness (of about 20 microns) of an acrylic block immersed in water was measured using the acoustic emission pressure field (in the kHz range) induced by the dynamic radiation force of ultrasound (2 MHz). The dynamic radiation force is produced by mixing two beams of different frequencies to excite the probed object. The acoustic emission is a result of object vibration at the difference frequency of the incident ultrasound beams and is detected by a low-frequency hydrophone placed nearby the block. Due to the presence of the block, an ultrasound standing wave field is generated as a result of multiple reflections between the transducer and the block’s surface. The acoustic emission by the block’s surface varies according to its relative position to the transducer. This variation is used to form an image of the surface roughness at two difference frequencies Δf=9.9 and 22.4 kHz. To have a one-to-one map between the surface roughness and the image, the surface variation has to lie within the distance from a maximum to its nearest minimum in the standing wave. Images obtained here demonstrate that vibroacoustography may be used as a powerful tool for the nondestructive inspection and imaging of surface roughness [Mitri et al., Appl. Phys. Lett. 88, 234105 (2006)]. [Work supported by NIH.]
Imaging surface roughness with continuous-wave ultrasound reflectometry.
Measurement of surface roughness irregularities is an important indicator of product quality for many nondestructive testing industries. Many techniques exist; however, because of their qualitative, time-consuming and direct-contact modes, it is of some importance to work out new experimental methods and efficient tools for quantitative estimation of surface roughness. Continuous-wave ultrasound reflectometry (CWUR) is presented here as a novel nondestructive modality for imaging and measuring surface roughness in a noncontact mode. In CWUR, voltage variations due to phase shifts in the reflected ultrasound waves are recorded and processed to form an image of surface roughness. An acrylic test block with surface irregularities ranging from 4.22 to 19.05 μm as measured by a coordinate measuring machine (CMM) is scanned by an ultrasound transducer having a diameter of 45 mm, a focal distance of 70 mm, and a central frequency of 3 MHz. It is shown that CWUR technique gives very good agreement with the results obtained through CMM inasmuch as the maximum average percent error is around 11.5%.
Measurement of prostate viscoelasticity using Shearwave Dispersion Ultrasound Vibrometry (SDUV): An in vitro study
Thyroid imaging with conventional ultrasound scanners does not always lead to conclusive results. Furthermore, current ultrasound imaging technology has difficulty in detecting important microcalcifications. Ambiguities in ultrasound and other thyroid imaging methods lead to a large number of unnecessary biopsies. For these reasons, alternative imaging methods capable of detecting both microcalcifications and lesions in thyroid are of great interest. This paper describes recent results on imaging human thyroids with vibro-acoustography. Experiments were conducted on eight excised human thyroids from autopsy. The specimens were each imbedded in a block of gel to simulate the surrounding tissue and to facilitate scanning. Three types of images were acquired from each specimen: X-ray, B-mode ultrasound, and vibro-acoustography. Anatomical details seen in the images were correlated and image quality was compared. X-ray images displayed calcifications with high contrast, but did not show anatomical details of soft tissue. B-mode displayed some soft tissue structures; however, the speckle masked the details and reduced the contrast. Vibro-acoustography displayed calcifications, anatomical details, and some nodules where they existed. Furthermore, vibro-acoustography images displayed tissue structures with high contrast and free from speckle. It is concluded that vibro-acoustography may be a suitable technique for thyroid imaging.
Comparative study of vibro-acoustography and B-mode ultrasound in prostate imaging
Vibro-acoustography (VA) is an imaging modality that uses the radiation force of ultrasound to vibrate tissue at a low frequency and records the resulting acoustic field to produce an image that is represents object characteristics at both ultrasound as well as low (audio) frequencies. Currently, B-mode ultrasound is used for prostate imaging. This imaging method has some limitations, including the speckle noise, which limit its ability in detection of lesions and calcifications. The purpose of this study is to explore the potentials of VA for prostate imaging. VA, B-mode ultrasound, and radiography were performed on 12 excised human prostate samples and the resulting images were compared. VA system parameters were, center frequency 3 MHz, Δf=50 kHz, image area 5×5 cm, pixel size 0.2×0.2 mm. Images evaluated in terms of visibility of anatomical and pathological structures and contrast. Results showed that prostate anatomical structures, mass lesions, and calcifications were visible in the VA images taken at different depths, and VA image quality was superior to B-mode. VA images exhibited significant contrast between the central and peripheral zones with enhanced borders. It is concluded that, with further development, VA may become suitable modality for in prostate imaging.
Simultaneous Sum-Frequency and Vibro-Acoustography Imaging for Nondestructive Evaluation (NDE) and Testing (NDT) Applications
High-resolution ultrasound imaging systems for inspection of defects and flaws in materials are of great demand in many industries. Among these systems, Vibro-acoustography (VA) has shown excellent capabilities as a non-contact method for non-destructive high-resolution imaging applications. This method consists of mixing two confocal ultrasound beams, slightly shifted in frequency, to produce an acoustic emission field at the difference frequency of the primary incident ultrasound beams. In addition to the difference frequency signal, there exists another signal at the sum frequency, formed in the intersection region of the two primary beams. The goal of this study is to investigate the formation of high-resolution images using the sum frequency of ultrasound waves in VA while concurrently forming the conventional difference-frequency VA image, thereby increasing the amount of information acquired during a single scan. A theoretical model describing the sum frequency wave propagation, including beam forming and image formation in the confocal configuration is developed and verified experimentally. Moreover, sample experiments are performed on a flawed fiber-reinforced ceramic composite plate. Images at both the difference and sum frequencies are compared and discussed. Results show that the sum frequency image produces a high-resolution C-scan of the plate by which the flaws and structural details of the plate can be detected.