Back to Authors

Morozov, Andrey P

Mayo Clinic

Mayo Clinic in Florida

Citations 7

Mammogram-Based Artificial Intelligence Risk Assessment in High-Risk Women Undergoing Supplemental Screening with MRI
Ogunlade, Samuel B. , Wang, Lian, Tavana, Anahita , Maimone, Santo , Robinson, Kristin A. , Moran, Kaitlin M., Leon, Amie , Morozov, Andrey P, Nwachukwu, Chidi T., Letter, Haley P, Maimone, Santo , Moran, Kaitlin M , Letter, Haley

Journal of Breast Imaging | July 2, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jbi/wbag046 Get It

Abstract Objective Current clinical risk models were developed for longer-term breast cancer risk stratification and therefore have limited utility for predicting short-term (1-year) breast cancer risk. This study evaluates the performance of a mammogram-based artificial intelligence (MB-AI) risk model for predicting breast cancer diagnosis within 1 year in high-risk women. Methods This retrospective case-control study included 340 women who underwent supplemental MRI screening within 1 year following a negative mammogram, of whom 101 (29.7%) developed breast cancer and 239 (70.3%) remained cancer-free during the same interval. Artificial-intelligence–assigned absolute 1-year risk scores, Tyrer–Cuzick (TC) lifetime and 10-year scores, and Gail lifetime and 5-year scores were analyzed. Model discrimination was evaluated using receiver operating characteristic (ROC) curves. Sensitivity, specificity, and predictive values were estimated at optimal cutoffs. Subgroup analyses examined model performance across genetic, menopausal, reproductive, and tumor-based strata. Results The MB-AI model demonstrated the highest overall discriminative ability (area under the curve [AUC] = 0.812), with strong performance in extremely dense breasts (AUC = 0.976). By comparison, TC lifetime (AUC = 0.625) and Gail lifetime (AUC = 0.668) models showed modest discrimination, while TC 10-year and Gail 5-year models did not discriminate (AUCs ≤0.49). Subgroup analyses showed consistent performance across clinical and pathological categories. The MB-AI model also showed an AUC comparable to that of previously developed AI models. Conclusions A mammogram-based AI model demonstrated improved performance compared with traditional clinical risk models for predicting breast cancer diagnosis within 1 year in women undergoing supplemental screening. These findings support that AI-based approaches may reflect both short-term risk and early imaging features of occult disease and suggest further investigation of AI as a complement to existing risk stratification strategies.
Comparison of High-Risk Breast Cancer Screenings with Concurrent Versus Staggered Breast MRI and Mammogram Schedules
Cornell, Lauren , Plante, Marie, Pai, Tanmayi, Li, Z, Maimone, Santo , Morozov, Andrey, Maxwell, Robert, Advani, Pooja, Robinson, Kristin, Li, Zhuo , Robinson, Kristin A. , Pai, Tanmayi , Cornell, Lauren F , Pai, Tanmayi Srinivas , Robinson, Kristin A , Maimone, Santo , Morozov, Andrey P, Maxwell, Robert W. , Advani, Pooja

Journal of Clinical Medicine | June 2, 2026 | Volume: 15 | Issue: 11 | Pages: 4239

10.3390/jcm15114239 Get It

Background: The current guidelines recommend that women at elevated risk for breast cancer (BC), defined as lifetime BC risk ≥ 20%, undergo annual screening with breast magnetic resonance imaging (MRI) and mammogram. However, limited evidence exists in the literature to guide the optimal timing of the MRI relative to the mammogram. Our study evaluated women undergoing high-risk BC screenings to determine the impact of timing for supplemental MRI on BC detection. Methods: Patients who completed high-risk screening MRI at a single institution from January 2019 through June 2022 were included. Baseline characteristics and clinical outcomes were collected through retrospective chart review. MRI exams were divided into two groups based on timing of MRI: concurrent (<90 days from mammogram) and staggered (≥90 days from mammogram). Results: Of 1115 patients initially identified, 770 met inclusion criteria, with a total of 3707 screening exams performed (2073 mammograms and 1634 MRIs). The final analysis included 1355 MRI exams for 712 patients, where a prior mammogram and MRI were available. Of the MRIs included, 784 (57.9%) were concurrent and 571 (42.1%) were staggered. Additional imaging was performed for 12.5% (98/784) of concurrent MRIs and 9.6% (55/571) of staggered MRIs. Biopsy rates were 9.8% (77/784) for concurrent and 7.0% (40/571) for staggered MRIs. In this high-risk population, there were surprisingly low BC detection rates, with a BC incremental detection rate of 0.5% in both the concurrent and staggered groups (p = 1.0), with the median size of detected invasive BCs equaling 5 mm in the concurrent group and 4 mm in the staggered group (p = 0.72). Conclusions: When comparing concurrent and staggered MRI regimens, there were no significant differences in incremental cancer detection rate, tumor size, rates of additional imaging, or negative biopsies. Further investigation with prospective analysis is needed to validate these findings.
Peri-Implant Enhancement of the Breast: Imaging Features, Significance, and Management Strategies
Maimone, Santo , Srivastava, Shweta, Ho, Olivia A. , Robinson, Kristin A. , Morozov, Andrey P, Letter, Haley , Leon, Amie , Rinker, Brian, Ho, Olivia S, Letter, Haley P, Maimone, Santo , Srivastava, Shweta

Journal of Breast Imaging | December 21, 2024 | Volume: 7 | Issue: 3 | Pages: 301-310

10.1093/jbi/wbae084 Get It

Abstract Objective Peri-implant enhancement can be seen on contrast-enhanced breast MRI, but its association with malignancy has not been described, leading to considerable variability in assessment and recommendations by radiologists. This study evaluated imaging features, management, and outcomes of implant-related enhancement. Methods This multisite IRB-approved retrospective review queried all breast MRI reports for keywords describing peri-implant enhancement, fluid, and/or masses (plus synonymous descriptions) and implant-associated malignancies, with subsequent imaging and chart review. Peri-implant enhancement and implant features were characterized. Assessments and outcomes were evaluated via clinical and imaging follow-up, aspiration/biopsy, and/or capsulectomy to evaluate for association of peri-implant enhancement with implant-related malignancy. Results A total of 100 patients had peri-implant enhancement. Uniform thin peripheral enhancement was most common (79/100, 79%). Capsulectomy was performed in 31/100 (31%), with benign capsular fibrosis/inflammation discovered in 26/31 (83.9%). Breast implant–associated anaplastic large cell lymphoma was present in 2/100 (2%), both with textured implants, while 98/100 (98%) had no implant-related malignancy. MRI recommendations varied: resume routine imaging (26/100, 26%), clinical management (18/100, 18%), follow-up MRI (17/100, 17%), MRI-directed US (17/100, 17%), aspiration/biopsy (11/100, 11%), and surgical consultation (10/100, 10%). Conclusion Peri-implant enhancement is a nonspecific imaging finding with a low malignant association, especially when seen in isolation (no associated effusion, mass, or adenopathy). Implant surface texture should be considered in management recommendations; diagnostic capsulectomy is not recommended in patients with smooth implants. Additional studies are encouraged to validate nonoperative management recommendations.
How Well Does Non-mass Enhancement Correlate With DCIS/Invasive Cancer?
Dufresne, Maria, Baksh, Mizba , Nussbaum, Samuel R., Kasbi, Ali Abbaszadeh, Mohammed, Ashary, Advani, Pooja , Morozov, Andrey P, McLaughlin, Sarah A. , Gabriel, Emmanuel , Nussbaum, Samuel , Abbaszadeh Kasbi, Ali, Morozov, Andrey, Gabriel, Emmanuel M , Huang, Kai , Dufresne, Maria M, Nussbaum, Samuel, Bagaria, Sanjay P.

The American Surgeon™ | February 14, 2023 | Volume: 89 | Issue: 12 | Pages: 5414-5420

10.1177/00031348231156776 Get It

Introduction Contiguous non-mass enhancement (NME) often coexists with a solid tumor component on MRI, but it can be challenging to predict whether NME represents invasive breast cancer, ductal carcinoma in situ (DCIS), benign disease, or biopsy site reaction. The purpose of this study was to determine the association between the size/extent of NME and the presence of invasive cancer and/or DCIS on final pathology. Methods This was a single institution retrospective analysis of a prospectively maintained breast cancer registry (2010-2020). Female patients who underwent surgical resection were included if they had a diagnosis of invasive breast cancer (with or without DCIS) and had an MRI showing both a solid mass and contiguous NME. The size of NME on MRI was compared with the size of invasive cancer and/or DCIS on the final pathology. Results From a total of 3443 patients, 225 patients were included. 86.2% had invasive ductal carcinoma (IDC), and 12.0% had invasive lobular carcinoma 76.9% were ER+, 16.4% were HER2+, and 13.3% were triple negative breast cancer (TNBC). 18.7% received neoadjuvant chemotherapy (NCT) of whom 31% achieved a complete radiographic/pathologic response. Pearson correlation coefficients (r) between the size of NME and invasive cancer/DCIS showed a strong and positive correlation of MRI NME with DCIS on pathology in patients without NCT. Subgroup analysis showed the strongest correlations for NME and DCIS among non-white (r = .70) and HER2 + patients (r = .74) who did not receive NCT. Conclusions Strong correlations between NME and DCIS were found for HER2 + disease and non-white patients, but only modest correlations were found for other patient/disease characteristics. These correlations may impact decisions in surgical approach.
Abbreviated Molecular Breast Imaging: Feasibility and Future Considerations
Maimone, Santo , Morozov, Andrey P, Letter, Haley , Robinson, Kristin A. , Wasserman, Martha, Li, Zhuo , Maxwell, Robert W. , Letter, Haley P, Wasserman, Martha C, Maimone, Santo

Journal of Breast Imaging | September 15, 2022 | Volume: 4 | Issue: 6 | Pages: 590-599

10.1093/jbi/wbac060 Get It

Abstract Objective Molecular breast imaging (MBI) is a supplemental screening modality consistently demonstrating incremental cancer detection over mammography alone; however, its lengthy duration may limit widespread utilization. The study purpose was to assess feasibility of an abbreviated MBI protocol, providing readers with mediolateral oblique (MLO) projections only and assessing performance in lesion detection and localization. Methods Retrospective IRB-exempt blinded reader study administered to 5 fellowship-trained breast imaging radiologists. Independent reads performed for 124 screening MBI cases, half abnormal and half negative/normal. Readers determined whether an abnormality was present, side of abnormality, and location of abnormality (medial/lateral). Abnormal cases had confirmatory biopsy or surgical pathology; normal cases had imaging follow-up ensuring true negative results. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess performance. A false negative result indicated that a reader failed to detect abnormal uptake; a false positive result indicated a reader incorrectly called an abnormality for a negative case. Tests for association included chi-square, Fisher-exact, and analysis of variance. Results Mean reader performance for detecting abnormal uptake: sensitivity 96.8%, specificity 98.7%, PPV 98.8%, and NPV 96.9%. Accuracy in localizing lesions to the medial or lateral breast was 100%. There were no associations in reader performance with reader experience, reader technique, lesion morphology, or lesion pathology. Median lesion size was 1.0 cm (range: 0.4–8.0 cm). All readers correctly identified 97.7% (42/43) of lesions with malignant or elevated risk pathology. Conclusion An abbreviated MBI protocol (MLO images only) maintained high accuracy in lesion detection and localization.
Abstract P3-03-19: Incidence and time to resolution of axillary adenopathy on mammography after COVID-19 vaccination
Robinson, Kristin A. , Advani, Pooja , Gococo-Benore, Denise A. , Qosja, Neda, Mummareddy, Ashita , Ashai, Ahmed M, Wilhelm, Annamaria, Maxwell, Robert W. , Wasserman, Martha, Patel, Neema , Morozov, Andrey P, Chumsri, Saranya , Maimone, Santo , Li, Zhuo

Cancer Research | March 8, 2022 | Volume: 82 | Issue: 4_Supplement | Pages: P3-03-19-P3-03-19

10.1158/1538-7445.sabcs21-p3-03-19 Get It

Abstract Background: This study reports incidence, timing, characteristics, and surveillance imaging of mammographic axillary adenopathy following COVID-19 vaccination. As COVID-19 immunizations continue, with possible booster vaccines upcoming, this study offers timing considerations and potential follow-up recommendations for breast imaging after vaccination. Methods: Retrospective analysis of patients (pts) who received at least one COVID-19 vaccine prior to screening (SM) or diagnostic mammography (DM) at Mayo Clinic Florida between January 15 to May 31, 2021. Vaccine-related information was queried by mammography technologists. Adenopathy was assessed by interpreting radiologists and follow-up studies were collated. Mammogram adenopathy included single enlarged node, multiple enlarged nodes, and adenopathy with soft tissue stranding. Ultrasound adenopathy included mildly prominent nodes with preserved fatty hila to rounded nodes with apparent loss of a fatty hilum. Wilcoxon rank-sum test and Fisher’s exact test were used to compare continuous and categorical variables, respectively. Multivariable logistic regression model was used to evaluate the association between days from vaccine and adenopathy. Results: Of 2349 pts, 34 (1.4%) had adenopathy (DM=6; SM=28) and 3 (0.1%) were symptomatic. Presence of axillary symptoms was associated with abnormal imaging (p&lt;0.001) with an odds ratio of 33 in multivariable model. Median time after vaccine for pts with adenopathy was significantly shorter at 14 days compared to 33 days for pts without adenopathy (p&lt;0.001). Incidence of adenopathy decreased as days from vaccine increased (3.4% for 0-14 days, 2.1% for 15-28 days, and 0.4% for &gt; 28 days, p&lt;0.001). After adjusting for being symptomatic, days from vaccine still had a significant impact on finding mammographic adenopathy (for each day after vaccine, OR=0.96, p&lt;0.001). No significant difference was seen based on age (p=0.66), vaccine brand (p=0.66), vaccine dose (p=0.18). ROC analysis to identify a cutoff value for presence/absence of adenopathy was 0.74 (95% CI 0.67-0.81) at 22.5 days following vaccination. Additional imaging with mammogram and/or ultrasound was requested for 31 pts. These included no follow-up (n=4, 12.9%), repeat ultrasound with or without mammogram in 1-3 months (n=26, 83.9%), and biopsy (n=1, 3.2%, pt with ipsilateral breast cancer with negative results, presumably vaccine induced). To date, all pts who underwent surveillance imaging demonstrated normalization of lymph node appearance. The median time for abnormal imaging related to adenopathy to return to BI-RADS 1 or 2 was 84 (range 13-157) days. Conclusion: The incidence of COVID-19 vaccine-induced adenopathy in this study (1.4%) appeared to be lower than self-reported axillary swelling in COVID-19 vaccine trials (16%) but is still higher than the reported incidence of adenopathy on an otherwise normal SM (0.02-0.04%). The incidence of adenopathy decreased significantly over time and was not present in most pts 28 days after the vaccine. In patients with abnormal adenopathy, followup imaging showed resolution of vaccine-induced adenopathy in most patients by 3 months. Adenopathy(N=34)No Adenopathy (N=2315)P valueAge0.66N342314Median (Range)63.5 (35.0, 83.0)64.0 (30.0, 94.0)Q1, Q351.5, 72.555.0, 71.0Exam type&lt;0.001DM6 (13.3%)39 (86.7%)SM28 (1.2%)2276 (98.8%)Symptomatic&lt;0.001Missing032Yes3 (23.1%)10 (76.9%)No31 (1.3%)2273 (98.7%)Vaccine brand0.66Missing119mRNA-127319 (1.7%)1117 (98.3%)BNT162b214 (1.2%)1138 (98.8%)Other0 (0.0%)41 (100.0%)Vaccine dose0.18Missing0181st9 (2.2%)409 (97.8%)2nd25 (1.3%)1888 (98.7%)Days from vaccine&lt;0.001Median (Range)14.0 (1.0, 91.0)33.0 (0.0, 239.0)Q1, Q38.2, 20.816.0, 61.0Days from Vaccine&lt;0.0010-1418 (3.4%)519 (96.6%)15-2811 (2.1%)513 (97.9%)&gt;285 (0.4%)1283 (99.6%) Citation Format: Kristin Robinson, Santo Maimone, Pooja P Advani, Zhuo Li, Denise Gococo-Benore, Neda Qosja, Ashita Mummareddy, Ahmed M Ashai, Annamaria Wilhelm, Robert Maxwell, Martha Wasserman, Neema Patel, Andrey Morozov, Saranya Chumsri. Incidence and time to resolution of axillary adenopathy on mammography after COVID-19 vaccination [abstract]. In: Proceedings of the 2021 San Antonio Breast Cancer Symposium; 2021 Dec 7-10; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2022;82(4 Suppl):Abstract nr P3-03-19.
Understanding Patient Anxiety and Pain During Initial Image-guided Breast Biopsy
Maimone, Santo , Morozov, Andrey P, Wilhelm, Annamaria, Robrahn, Inna, Whitcomb, Tedra D, Lin, Kathryn Y, Maxwell, Robert W. , Maimone, Santo

Journal of Breast Imaging | September 29, 2020 | Volume: 2 | Issue: 6 | Pages: 583-589

10.1093/jbi/wbaa072 Get It

Abstract Objective Image-guided breast biopsies are safe, efficient, and reliable. However, patients are often anxious about these procedures, particularly those who have never undergone a prior biopsy. Methods This prospective IRB-approved study surveyed 163 patients undergoing their first breast biopsy. Participants provided informed consent and completed a short written survey prior to and immediately after their procedure. Level of anxiety as well as anticipated and actual levels of pain prior to and following the procedure were assessed using a 0–10-point Likert scale. Correlation, bivariate, and regression analyses were performed. Results Regarding the biopsy experience, 133/163 (81.6%) of patients reported it as better than expected. Anxiety decreased significantly from a prebiopsy mean score of 5.52 to a postbiopsy mean score of 2.25 (P &lt; 0.001). Average and greatest pain experienced during the procedure had mean scores of 2.03 and 2.77, respectively, both significantly lower compared to preprocedural expectation (mean 4.53) (P &lt; 0.001). Lower pain scores were reported in US-guided procedures compared to stereotactic- and MRI-guided biopsies (P &lt; 0.001). No significant differences in pain scores were seen in those undergoing single versus multiple biopsies, or when benign, elevated-risk, or malignant lesions were sampled. Positive correlations were seen with prebiopsy anxiety levels and procedural pain as well as with anticipated pain and actual procedural pain. Conclusion Image-guided biopsies are often better tolerated by patients than anticipated. We stress the benefit of conveying this information to patients prior to biopsy, as decreased anxiety correlates with lower levels of pain experienced during the procedure.