Back to Authors

Heikal, Nahla

Mayo Clinic

Mayo Clinic

Citations 16

Diagnostic Utility of High Dose Heparin Confirmation Step in Heparin Induced Thrombocytopenia ELISA Assay
Leger, Rachel, Ashrani, Aneel A. , Pruthi, Rajiv K. , Padmanabhan, Anand , Heikal, Nahla, Saadalla, Abdulrahman , Chen, Dong

Blood | November 24, 2021 | Volume: 138 | Issue: Supplement 1 | Pages: 3228-3228

10.1182/blood-2021-154504 Get It

Abstract Introduction: Heparin-induced thrombocytopenia (HIT) is a potentially life-threatening condition that could occur following exposure to heparin. Accurate and timely diagnosis is critical for appropriate clinical management. Laboratory testing for suspected cases is based on screening for the presence of serum anti-PF4/heparin antibodies using solid-phase enzyme-linked immunosorbent assay (ELSIA) which is known to be sensitive but less specific. A positive ELISA test is followed by functional testing to demonstrate the platelet activating properties and heparin dependence of the pathogenic antibodies. Serotonin release assay (SRA) is considered the gold standard functional test for the diagnosis of HIT. In most anti-PF4/heparin ELISA assays, a high-dose heparin buffer (100U/mL) confirmation step is recommended to demonstrate heparin dependence of detected antibodies and increase the specificity of the assay. The necessity of this confirmation step is controversial with some reports suggesting it could lead to misinterpreting positive ELISA results as negative or indeterminate, especially in cases of very strong and high titer HIT activating antibodies. We hence aimed to investigate the utility of applying this confirmation step as part of an inhouse validation study of a mass spectrometry-coupled SRA (Mayo-SRA). Materials: Three hundred archived serum samples were tested using anti-PF4/heparin IgG antibody ELISA (Immucor Diagnostics, GA, USA). High-dose heparin (100U/mL) confirmation step was performed on all samples with OD units ≥0.4 as recommended by the manufacturer. Samples with OD ≥ 0.4 and ≥50% OD inhibition in the high dose heparin confirmation step are interpreted positive. Mayo-SRA results were compared to a reference 14C SRA method. The 4T clinical score was retrospectively calculated for all patient (range 0-8 points). Results: Of the 300 tested samples, 57 samples were interpreted positive by the anti-PF4/heparin screening ELISA. 33 of the 57 samples were positive using the reference 14C SRA method, whereas 43 samples were positive by Mayo-SRA assay (≥20% serotonin release). Three additional samples were positive by Mayo-SRA, but negative by both screening ELISA and the reference 14C SRA method. All samples with OD units ≥0.4 displayed >50% inhibition in the high-dose heparin regardless of the intensity of the initial OD value or the HIT 4T score, with the exception of one that was negative by both SRA methods and of 1.35 OD value and 6 4T HIT score (Fig-1A). Importantly, thirteen samples were anti-PF4/heparin positive, but SRA negative (by Mayo-SRA and reference method). These samples also displayed positive %heparin inhibition (≥50% OD inhibition) (Fig-1B). Lastly, there were no differences in the degree of %inhibition in samples positive by both reference and Mayo-SRA or Mayo-SRA only (Fig-1B). Conclusion: In our patient cohort, addition of the high dose heparin inhibition confirmation step to the screening anti-PF4/heparin ELISA assay was of no additional diagnostic utility. We hence propose eliminating the heparin inhibition step which would improve laboratory turnaround time, reduce costs, and importantly speed up urgent clinical management decisions. Figure Legend: Fig-1A. No correlation between initial OD values and %OD inhibition using high dose heparin. Scatter plot of all ELISA positive samples (OD ≥0.4) grouped according to OD values. Samples include all SRA-positive and thirteen SRA-negative ELISA-positive samples. Fig-1B. Scatter plot of %OD inhibition comparing samples positive by Mayo-SRA and reference SRA method, positive by Mayo-SRA only, and ELISA-positive SRA-negative by both methods. Figure 1 Figure 1. Disclosures Pruthi: Bayer Healthcare AG: Honoraria; CSL Behring: Honoraria; Merck: Honoraria; Genentech: Honoraria; HEMA Biologics: Honoraria; Instrumentation Laboratory: Honoraria. Padmanabhan: Veralox Therapeutics: Membership on an entity's Board of Directors or advisory committees.
Determination of Relapse Risk By Complement Gene Variants after Eculizumab Discontinuation in Complement-Mediated Thrombotic Microangiopathy: A Retrospective Review
Moyer, Ann M. , Rios, Christianne Bourlon De Los, Heikal, Nahla, Tran, Cheryl L. , Acosta‐Medina, Aldo A. , Go, Ronald S. , Willrich, Maria Alice V. , Alkhateeb, Hassan B. , Chen, Dong , Fervenza, Fernando C. , Leung, Nelson , Marshall, Ariela L. , Winters, Jeffrey L. , Sridharan, Meera

Blood | February 6, 2021 | Volume: 136 | Issue: Supplement 1 | Pages: 25-26

10.1182/blood-2020-136617 Get It

Background Eculizumab, a monoclonal antibody targeting C5, is an effective treatment for complement-mediated thrombotic microangiopathy (CM-TMA), also known as atypical hemolytic uremic syndrome. Although lifelong therapy has been suggested, the optimal treatment schedule is unknown, while eculizumab discontinuation does not universally lead to relapse. Data evaluating risk factors associated with an increased risk of CM-TMA recurrence following eculizumab withdrawal are scarce. Prior to the eculizumab era, complement genetic studies have been used to assess morbidity and mortality in patients with CM-TMA. Our aim was to assess the impact of complement gene variants on CM-TMA relapse rate (RR) after eculizumab discontinuation. Methods Search protocols were developed for the Ovid and PubMed databases to identify existing reports on CM-TMA and eculizumab withdrawal published before February 1st 2020. Cases were cross-referenced to eliminate duplicates. Inclusion criteria included patients diagnosed with CM-TMA who had undergone eculizumab discontinuation. Reasons for exclusion were patients with no follow-up after eculizumab withdrawal and patients lacking complement gene testing. Patients undergoing eculizumab dose extension, but not discontinuation, were not included. Results Fifteen studies including 557 individuals were retrieved. Of these, 363 (65.2%) were excluded as outlined in Figure 1 and 194 cases were included in the final analysis with a global RR of 28.9% (n=56). Distribution based on gene impacted and variant type are presented in Table 1. RR was highest among patients with CFH variants (52.5% to 60%) -particularly if involving exon 22 or nonsense mutations-, MCP/CD46 variants (38.9% to 45%) -particularly if affecting splice regions-, and cases with multiple concomitant variants (57.1%) -particularly those including CFH or a CFH-CFHR1 Hybrid (Table 2). Patients with relapse were more likely to have the presence of a complement variant (p<0.001), history of previously resolved CM-TMA events (p=0.022), younger age (mean age 22.4 years for patients with relapse vs. 32.33 years for patients without relapse; p=0.002) and, within those with detected variants, multiple vs. single variants (p=0.002) and CFH-inclusive variants (p=0.003). On univariate analysis, complement gene variants (OR 4.217 95%CI 1.97-9.026; p<0.001), age <30 years (OR 2.346 95%CI 1.159-4.749; p=0.018), and presence of multiple variants (OR 2.06 95%CI 1.172-3.621; p=0.012) or CFH-inclusive variants (OR 3.111 95%CI 1.443-6.71; p=0.004) were associated with increased odds of CM-TMA relapse, while no prior history of additional CM-TMA events was the only factor associated with lower RR (OR 0.327 95%CI 0.123-0.87; p=0.025). Presence of complement variants (OR 4.48 95%CI 1.132-17.724; p=0.033) and CFH-inclusive variants (OR 3.045 95%CI 1.136-8.159; p=0.027) were independently associated with increased RR on multivariate analysis (Table 3). Conclusion Relapse after eculizumab discontinuation is rare in cases with no genetic variants identified but can increase to more than 80% in high-risk subgroups. Complement genetic testing is not required for CM-TMA diagnosis or for initiation of complement inhibiting therapy; however, our results demonstrate the value of complement genetic testing when stratifying risk of patients for consideration of eculizumab discontinuation. Disclosures Sridharan: Alexion: Honoraria.
Revisiting the effects of spectral interfering substances in optical end‐point coagulation assays
Seheult, Jansen N. , Dalenberg, Daniel A., Stuart, Melissa K. , Moericke, Katherine, Cardel, Laynalee K., Heikal, Nahla, Chen, Dong , Pruthi, Rajiv K. , Dalenberg, Daniel, Sridharan, Meera R, Stuart, Melissa, Cardel, Laynalee, Pruthi, Rajiv K , Chen, Dong , Seheult, Jansen N , Sridharan, Meera

International Journal of Laboratory Hematology | January 17, 2021 | Volume: 43 | Issue: 5 | Pages: 1181-1190

10.1111/ijlh.13465 Get It

AbstractIntroductionHemolysis, icterus, and lipemia (HIL) are common pre‐analytical variables in the clinical laboratory. Understanding their effects on coagulation laboratory results is essential.MethodsHIL effects on the prothrombin time (PT), activated partial thromboplastin time (APTT), dilute Russell's viper venom time (DRVVT), thrombin time (TT), and protein C chromogenic activity (CFx) were evaluated on the ACL TOP 750 optical analyzer and STA‐R Evolution mechanical analyzer (PT and APTT only) by spiking normal donor, patient, and commercial control samples with varying concentrations of hemolysate, bilirubin, or a lipid emulsion. The relative difference or bias compared to the original results was determined.ResultsHemolysis (H) indices up to 900 mg/dL did not affect the APTT, PT, DRVVT Confirm, TT, and CFx; however, H indices above approximately 200 mg/dL resulted in a false‐negative DRVVT screen and screen/confirm ratio in samples with a lupus anticoagulant. There was an artifactual prolongation of the PT and APTT when conjugated bilirubin was dissolved in aqueous solvents and not when it was dissolved in dimethyl sulfoxide. Icterus (I) indices up to 45 mg/dL did not result in significant (>15%) bias for all assays evaluated. The PT and APTT assays failed to produce a robust clot curve when the lipemia (L) index exceeded 6000 milliabsorbance units (mAbs), and the TT and DRVVT assays failed when the L index exceeded 3000 mAbs; the CFx assay was unaffected by lipemia.ConclusionsVerification of the manufacturer's recommended interference thresholds is important since it may avoid inappropriate instrument flagging and/ or sample rejection.
Thrombophilia Testing Practices: The Mayo Clinic Experience
Scheckel, Caleb , Pruthi, Rajiv K. , Ashrani, Aneel A. , Heikal, Nahla, Marshall, Ariela L. , Chen, Dong

Blood | November 4, 2020 | Volume: 136 | Issue: Supplement 1 | Pages: 39-40

10.1182/blood-2020-141633 Get It

Introduction: The 2013 ASH Choosing Wisely campaign recommends against thrombophilia testing in patients with major transient risk factors for venous thromboembolism (VTE). Our Special Coagulation Laboratory (SCL) offers an algorithmic approach to thrombophilia testing which includes assays for lupus anticoagulant, dysfibrinogenemia, anticoagulant proteins (protein C, protein S, antithrombin), activated protein C resistance with reflex to factor v Leiden (if indicated), and prothrombin G20210A mutation. Samples are received through Mayo Clinic Laboratories (MCL), national and international reference laboratory (often with limited or no clinical information) and from internal Mayo Clinic practice. We hypothesized that thrombophilia testing would decline in cases where it was recommended against following the publication of testing guidelines. Methods: We audited the external thrombophilia testing samples between2013-2019 and internal samples between 2014-2019 (periods during which they were available). For the internal samples, complete test volumes were only available 2014-2019. Because external clients may either adopt internal testing or contract with a different reference laboratory, many clients may not have been retained over the entire observed period. To better understand the ordering practices of consistent clients, external clients which did not have thrombophilia testing sent to MCL each year of the observed period were excluded. We separated internal ordering practices by hematology and oncology or thrombophilia clinic staff and trainees contrasted with those of other specialties. Results: MCL received 18,529 external thrombophilia testing samples from 322 external healthcare systems during the observed period. From 37 clients, 5,878 (38.2%) samples met inclusion criteria. Annual volume of samples ranged from 890 in 2013 to 861 in 2019 (861-1046). Special coagulation lab processed 11,639 internal thrombophilia tests during the observed periods. There was a consistent small annual increase in testing with 1,398 performed in 2014 and 2,430 in 2019. Of 11651 tests ordered, only 18.6% (2167) were ordered by people most likely to be familiar with ASH choosing wisely campaign. Annual thrombophilia testing ordered by hematology and oncology or thrombophilia clinic staff increased from 307 in 2014 to 387 in 2019 (307-432). However, the ordering practices of these providers as a proportion of overall practices declined from 22.0% (307/1398) in 2014 to 15.9 % (387/2430) in 2019. Table Discussion: Our preliminary data showed no significant trend in thrombophilia ordering practices among included external clients since publication of the ASH Choosing Wisely guidelines on thrombophilia testing. Internally we found a consistent small rise in numbers of thrombophilia tests ordered since 2014 but this may reflect changes in patient volume. We observed that the majority of internal thrombophilia testing was ordered by non-hematology/oncology or thrombophilia providers who are perhaps less likely to be familiar with ASH Choosing Wisely guidelines. The proportion of testing ordered by hematology & oncology or thrombophilia providers declined during the observed period. Our findings are limited by lacking information on the indication and appropriateness for testing as well as possibility of change in patient population. However the overall trend in test volumes and specialty of ordering providers deserves attention and highlight the value in educating other medical societies on ASH Choosing Wisely recommendations for thrombophilia testing. Future work will focus on appropriateness for thrombophilia testing including the indication and time (remote from anticoagulation and acute thrombotic episode), location of testing (inpatient vs. outpatient), as well as investigating if testing has changed patient management, which may help in creating new Choosing Wisely recommendations for thrombophilia testing. Figure 1. Disclosures Pruthi: HEMA Biologics: Honoraria; Bayer Healthcare: Honoraria; Merck: Honoraria; Instrumentation Laboratory: Honoraria; Genentech Inc.: Honoraria; CSL Behring: Honoraria.
Evaluation of Soluble Fibrin Monomer Complex in Patients with Sars-Cov-2 COVID-19 Infection
Ashrani, Aneel A. , Heikal, Nahla, Pruthi, Rajiv K. , Sridharan, Meera , Chen, Dong , Marshall, Ariela L.

Blood | November 4, 2020 | Volume: 136 | Issue: Supplement 1 | Pages: 27-28

10.1182/blood-2020-136717 Get It

Introduction: In patients with SARS-CoV-2 COVID-19 infection elevated D-dimers are associated with a poor prognosis. Although suggestive of DIC, the majority of patients do not fulfil ISTH criteria for DIC. Studies have demonstrated that when compared to D-dimer, fibrin monomers are more sensitive and specific when differentiating overt DIC from non-overt DIC. Our special coagulation laboratory (SCL) routinely measures soluble fibrin monomer complex (SFMC) as part of our DIC profile in samples with elevated D-dimers. Here we aimed to investigate the percentage of patients with COVID-19 infection with elevated SFMC as performed as part of the DIC profile. Methods: Between April 1st 2020 and July 26, 2020 inpatients at the Mayo Clinic Rochester, MN campus with COVID-19 infection who underwent DIC testing in SCL were identified through SCL database. Patients were excluded if SARS-CoV2 PCR results were not available in the Mayo Clinic electronic medical record (EMR). DIC profile components include prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen and D-dimer. Reflex SFMC is performed if D-dimer is elevated. Data abstracted from EMR included results of laboratory tests, date of COVID-19 symptom onset, date of SARS-CoV2 PCR positivity, and death within 30 days of hospital admission. The ISTH DIC score was calculated and patients were labeled as overt DIC or non-overt DIC based off of ISTH DIC score ≥5. Results: 35 patients (19 female), median age 59 years (28-91) met our study criteria DIC profiles were obtained 6.5 (1-37) days after COVID-19 symptom onset (n=33) with 28 obtained within 14 days of symptom onset. Time to DIC profile from SARS-CoV2 PCR testing was 4 (0-37) days (n=35) with 31 having testing completed within 14 days of PCR positivity. 8 patients were intubated during hospitalization and of the remaining 27, 67% required supplemental oxygen. 21/35 (60%) patients had an elevated fibrinogen (526.5 mg/dL (201-800)) while 19/35 (54%) had a prolonged PT (12.8 seconds (10.1-99.6) and 5/35 (14%) had a prolonged APTT (31 seconds (24-68)). 17 patients with prolonged PT and 3 patients with prolonged APTT had factor activity assays performed (Figure 1A). 9/35 (25%) had thrombocytopenia (230 x 109/L (12-709) and 27/35 (77%) patients had an elevated D-dimer (895 ng/ml FEU (220- >100,000). D-dimer was higher in males than in females (p: 0.049). Of those with elevated D-dimer only 5/27 (18.5%) had an elevated SFMC (5 mcg/ml (5- >1100) (Figure 1B). 4/35 (11%) patients had ISTH DIC scores ≥ 5 and all had score of 5. All of these patients had D-dimer > 2000 ng/ml while only 2 had elevated SFMC however SFMC in both of these patients was < 15 mcg/ml. Of these, one patient with SFMC of 12 mcg/ml had known cirrhosis and the other with an SFMC of 11 mcg/ml had acute decompensation and associated shock liver. This patient also had venous thrombosis 3 days prior to DIC profile and died from complications related to COVID-19 infection. Of the two other patients with high ISTH score and normal SFMC, one had previous chronic thrombocytopenia of < 50 x109/L while the other had concomitant admission for acute and recurrent pancreatitis in the setting of alcoholism with acute intoxication. Six patients died within 30 days of admission and in 2/5 performed SFMC was elevated (Figure1C). Conclusion: Compared to 77% of patients with elevated D-dimers, of those tested only 18.5 % of patients had elevated SFMC. It has been hypothesized that the elevated D-dimer noted in COVID-19 pulmonary infection is a direct consequence of acute lung injury and not overt DIC. Although preliminary, the small percentage of patients with overt DIC by ISTH criteria and normal SFMC in the majority of the current cohort support this hypothesis; however studies in a larger more controlled cohort are needed to confirm these findings. Disclosures Sridharan: Alexion: Honoraria. Pruthi:Merck: Honoraria; Instrumentation Laboratory: Honoraria; HEMA Biologics: Honoraria; Bayer Healthcare: Honoraria; Genentech Inc.: Honoraria; CSL Behring: Honoraria.
An In Silico Exploration of the Factors That Affect the Precision of the Bethesda Assay
Seheult, Jansen N. , Cardel, Laynalee K., Tange, Julie I, Ashrani, Aneel A. , Nichols, William L., Heikal, Nahla, Chen, Dong , Cardel, Laynalee, Ashrani, Aneel, Chen, Dong , Seheult, Jansen N

American Journal of Clinical Pathology | May 15, 2020 | Volume: 154 | Issue: 5 | Pages: 671-682

10.1093/ajcp/aqaa085 Get It

Abstract Objectives Despite more than 40 years of experience performing the Bethesda assay (BA), poor intra- and interlaboratory precision remains the biggest laboratory challenge to date. Methods The BA procedure was modeled using stochastic simulation techniques to determine the precision of the BA up to dilutions of 1:4,096, to estimate the minimum significant relative change at various inhibitor titers, and to understand the laboratory procedural variables that could significantly affect the performance of the BA at high dilutions. Results Selecting the lowest dilution tube with a residual activity closest to 25% for calculating the reported Bethesda titer (BT), using a factor activity assay with a coefficient of variation less than or equal to 7.5% in the range of 15% to 50% factor activity level, performing the factor activity measurement in replicates, and minimizing pipette volumetric error resulted in the lowest imprecision in the reported BT. The factor neutralization kinetics of the inhibitor appear to have little impact on the precision of the assay if the incubation time is greater than 90 minutes. Conclusions This in silico model will assist future laboratory efforts in standardizing the quantification of specific coagulation factor inhibitors and improving the precision of the reported results.