Back to Authors

Algeciras‐Schimnich, Alicia

https://orcid.org/0000-0002-4455-6217

Mayo Clinic

Mayo Clinic

Citations 137

Assessment of complement interference in anti-Müllerian hormone immunoassays
Turner, Katherine A., Larson, Bethany J., Kreofsky, Nina C., Bornhorst, Joshua A. , Bornhorst, Joshua , Willrich, Maria Alice V. , Algeciras‐Schimnich, Alicia

Clinical Chemistry and Laboratory Medicine (CCLM) | July 11, 2019 | Volume: 58 | Issue: 1 | Pages: e8-e10

10.1515/cclm-2019-0496 Get It

Human chorionic gonadotropin suspected heterophile interference investigations in immunoassays: a recommended approach
Jara-Aguirre, Jose C., Baumann, N, Block, Darci R , Baumann, Nikola A, Algeciras‐Schimnich, Alicia

Clinical Chemistry and Laboratory Medicine (CCLM) | July 6, 2019 | Volume: 57 | Issue: 8 | Pages: 1192-1196

10.1515/cclm-2018-1142 Get It

Abstract Background Heterophile antibody (HAb) interferences in immunoassays can cause falsely elevated hCG concentrations leading to incorrect diagnosis and treatments options. When results are not consistent with the clinical findings, hCG HAb interference investigation may be requested by the physician. A retrospective evaluation of the frequency of HAb interference was performed among cases of physician-requested investigations and the effectiveness of commercially available blocking reagents to detect HAb interference in two immunoassay systems was evaluated. Methods One hundred and thirteen physician requests for hCG HAb investigation from 2008 to 2017 were reviewed. The primary method used to measure hCG was the Beckman Coulter Access Total βhCG (2008–2010) and the Roche Elecsys HCG+β (2014–2017). HAb investigation included measurement by two immunoassays before and after treatment of samples with heterophile blocking reagents and serial dilution studies. Results Five cases of HAb and HAb-like interference were identified. The interference frequency was 6.7% for the Beckman assay and 2.9% for the Roche assay. The presence of HAb was detected using heterophile blocking reagents and an alternative method in three cases. The other two cases were detected due to discrepant results with an alternative method and non-linear serial dilutions (HAb-like). Conclusions HAb interference was observed in the Beckman and the Roche assays. The heterophile blocking reagents failed to detect 40% of interference cases. Blocking reagents should not solely be used for these investigations. Multiple strategies including the use of serial dilutions and using an alternative platform are critical when troubleshooting interferences in hCG immunoassays.
SAT-390 New Cortisol Threshold for Diagnosis of Adrenal Insufficiency After Cosyntropin Stimulation Testing Using the Elecsys Cortisol II, Access Cortisol, and LC-MS/MS Assays
Javorsky, Bradley R. , Colón-Franco, Jessica M , Findling, James W. , Carroll, Ty B , Algeciras‐Schimnich, Alicia , Singh, Ravinder J.

Journal of the Endocrine Society | May 10, 2019 | Volume: 3 | Issue: Supplement_1 | Pages: No page available

10.1210/js.2019-sat-390 Get It

GALAD Score for Hepatocellular Carcinoma Detection in Comparison with Liver Ultrasound and Proposal of GALADUS Score
Yang, Ju Dong , Addissie, Benyam D., Mara, Kristin C. , Harmsen, William S. , Dai, Jianliang , Zhang, Ning , Wongjarupong, Nicha , Ali, Hawa M. , Ali, Hamdi A. , Hassan, Fatima, Lavu, Sravanthi , Cvinar, Jessica, Giama, Nasra H., Moser, Catherine D., Miyabe, Katsuyuki , Allotey, Loretta K., Theobald, Jannick , Ward, Melissa M., Nguyen, Mindie H. , Befeler, Alex S. , Reddy, K. Rajender , Schwartz, Myron , Harnois, Denise M. , Srivastava, Sudhir , Rinaudo, Jo Ann, Feng, Ziding , Marrero, Jorge A. , Roberts, Lewis R. , Hassan, Fatima A, Cvinar, Jessica L, Theobald, J Paul, Roberts, Lewis R , Miyabe, Katsuyuki , Mara, Kristin C , Yang, Ju Dong , Algeciras‐Schimnich, Alicia , Theobald, J. Paul, Yamada, Hiroyuki , Gores, Gregory J.

Cancer Epidemiology, Biomarkers & Prevention | November 21, 2018 | Volume: 28 | Issue: 3 | Pages: 531-538

10.1158/1055-9965.epi-18-0281 Get It

Abstract Background: The GALAD score is a serum biomarker–based model that predicts the probability of having hepatocellular carcinoma (HCC) in patients with chronic liver disease. We aimed to assess the performance of the GALAD score in comparison with liver ultrasound for detection of HCC. Methods: A single-center cohort of 111 HCC patients and 180 controls with cirrhosis or chronic hepatitis B and a multicenter cohort of 233 early HCC and 412 cirrhosis patients from the Early Detection Research Network (EDRN) phase II HCC Study were analyzed. Results: The area under the ROC curve (AUC) of the GALAD score for HCC detection was 0.95 [95% confidence interval (CI), 0.93–97], which was higher than the AUC of ultrasound (0.82, P <0.01). At a cutoff of −0.76, the GALAD score had a sensitivity of 91% and a specificity of 85% for HCC detection. The AUC of the GALAD score for early-stage HCC detection remained high at 0.92 (95% CI, 0.88–0.96; cutoff −1.18, sensitivity 92%, specificity 79%). The AUC of the GALAD score for HCC detection was 0.88 (95% CI, 0.85–0.91) in the EDRN cohort. The combination of GALAD and ultrasound (GALADUS score) further improved the performance of the GALAD score in the single-center cohort, achieving an AUC of 0.98 (95% CI, 0.96–0.99; cutoff −0.18, sensitivity 95%, specificity 91%). Conclusions: The performance of the GALAD score was superior to ultrasound for HCC detection. The GALADUS score further enhanced the performance of the GALAD score. Impact: The GALAD score was validated in the United States.
Thyroglobulin measurement in the management of patients with differentiated thyroid cancer
Algeciras‐Schimnich, Alicia

Critical Reviews in Clinical Laboratory Sciences | March 16, 2018 | Volume: 55 | Issue: 3 | Pages: 205-218

10.1080/10408363.2018.1450830 Get It

Laboratory Services for Managing Thyroid Disease: Different and Common Viewpoints of American Thyroid Association Members and of Members of the Endocrine Division of the American Association for Clinical Chemistry
Grebe, Stefan K., A, on behalf of the American Thyroid, Grebe, Stefan K G, Algeciras‐Schimnich, Alicia

Thyroid | November 8, 2017 | Volume: 27 | Issue: 12 | Pages: 1583-1585

10.1089/thy.2017.0387 Get It

United States and European Multicenter Prospective Study for the Analytical Performance and Clinical Validation of a Novel Sensitive Fully Automated Immunoassay for Calcitonin
Kahaly, George J. , Davis, Thomas E., Diana, Tanja, Feldkamp, Joachim , Karger, Stefan, Lupo, Mark A. , Raue, Friedhelm , Ringel, Matthew D. , Sipos, Jennifer A. , Kratzsch, Jüergen, Algeciras‐Schimnich, Alicia , König, J. , Ringel, Matthew D

Clinical Chemistry | July 7, 2017 | Volume: 63 | Issue: 9 | Pages: 1489-1496

10.1373/clinchem.2016.270009 Get It

Abstract BACKGROUND The objective of this study is the validation and proof of clinical relevance of a novel electrochemiluminescence immunoassay (ECLIA) for the determination of serum calcitonin (CT) in patients with medullary thyroid carcinoma (MTC) and in different diseases of the thyroid and of calcium homeostasis. METHODS This was a multicenter prospective study on basal serum CT concentrations performed in 9 US and European referral institutions. In addition, stimulated CT concentrations were measured in 50 healthy volunteers after intravenous calcium administration (2.5 mg/kg bodyweight). RESULTS In total, 1929 patients and healthy controls were included. Limits of blank, detection, and quantification for the ECLIA were 0.3, 0.5, and 1 ng/L, respectively. Highest intra- and interassay coefficients of variation were 7.4% (CT concentration, 0.8 ng/L) and 7.0% (1.1 ng/L), respectively. Medians (interval) of serum CT concentrations in 783 healthy controls were 0.8 ng/L (<0.5–12.7) and 3 ng/L (<0.5–18) for females and males, respectively (97.5th percentile, 6.8 and 11.6 ng/L, respectively). Diagnostic sensitivity and specificity were 100%/97.1% and 96.2%/96.4%, for female/males, respectively. Patients (male/female) with primary hyperparathyroidism, renal failure, and neuroendocrine tumors showed CT concentrations >97.5th percentile in 33%/4.7%, 18.5%/10%, and 8.3%/12%, females/males, respectively. Peak serum CT concentrations were reached 2 min after calcium administration (161.7 and 111.8 ng/L in males and females, respectively; P < 0.001). CONCLUSIONS Excellent analytical performance, low interindividual variability, and low impact of confounders for increased CT concentrations in non-MTC patients indicate that the investigated assay has appropriate clinical utility. Calcium-stimulated CT results suggest good test applicability owing to low interindividual variability.
55: Evaluation of the Clinical and Laboratory Standards Institute EP26-A Guideline: A Protocol for Reagent Lot-to-Lot Verification
Katzman, Brooke M. , Ness, Karl M. , Algeciras‐Schimnich, Alicia

American Journal of Clinical Pathology | February 3, 2017 | Volume: 143 | Issue: suppl_1 | Pages: A028-A028

10.1093/ajcp/143.suppl1.029 Get It

Commentary
Algeciras‐Schimnich, Alicia

Clinical Chemistry | September 28, 2016 | Volume: 62 | Issue: 10 | Pages: 1316-1317

10.1373/clinchem.2016.256081 Get It

Detection of IGF-1 Protein Variants by Use of LC-MS with High-Resolution Accurate Mass in Routine Clinical Analysis
Hines, Jolaine, Ketha, Hemamalini , Grebe, Stefan K., Milošević, Dragana , Taylor, Robert L. , Algeciras‐Schimnich, Alicia , Singh, Ravinder

Clinical Chemistry | April 28, 2015 | Volume: 61 | Issue: 7 | Pages: 990-991

10.1373/clinchem.2014.234799 Get It