Back to Authors

Brown, Thomas E.

https://orcid.org/0000-0001-7810-9821

Mayo Clinic

Mayo Clinic in Florida

Citations 5

Normothermic Regional Perfusion: Why Isn't the Lactate Coming Down?
Cywes, Claire , Brown, Thomas E. , Aniskevich, Stephen , Croome, Kristopher P, Croome, Kristopher P. , Croome, Kris P , Aniskevich, Stephen

Clinical Transplantation | March 8, 2026 | Volume: 40 | Issue: 3 | Pages: No page available

10.1111/ctr.70489 Get It

ABSTRACT During normothermic regional perfusion (NRP), lactate is the most commonly used liver viability marker. Lactate production from pyruvate breakdown in erythrocytes is not suspended during pRBC storage. By transfusing blood at a variety of stored ages, variable amounts of lactate are added to the NRP circuit and may influence serial lactate measurements. Sixteen DCD donors undergoing NRP were enrolled in a prospective study. Samples were drawn from pRBC bags prior to use in the NRP circuit and were tested for lactate values. Lactate values of the NRP circuit perfusate were also assessed Q15 min. Lactate values of the pRBCs varied from 4.4 mmol/L to >20 mmol/L and were strongly correlated with the age of the stored blood ( r 2 = 0.74). Donors in which the pRBCs were > = 20‐days from expiration (Newer Blood group) had a significantly lower lactate at 60 min of NRP compared to donors in which pRBCs were <20 day from expiration (Older Blood group) (4.0±2.0 mg/dL vs. 6.3±2.3 mg/dL; p = 0.048). If the lactate is not decreasing as anticipated, transfusion of older pRBC should be entertained as one possible explanation. In cases where the liver seems acceptable for transplantation, additional lactate testing with longer time on NRP or sequential NRP/NMP should be considered in lieu of declining the liver outright.
Development of a portable abdominal normothermic regional perfusion (A-NRP) program in the United States
Croome, Kristopher P. , Brown, Thomas E. , Mabrey, Richard L., Sonnenwald, Sherry L., Burns, Justin M. , Mao, Shennen A. , Clendenon, Jacob N. , Nguyen, Justin H. , Perry, Dana K. , Maddox, Rebecca G., Clendenon, Jacob , Taner, Burcin , Croome, Kris P , Mao, Shennen A , Taner, C. Burcin

Liver Transplantation | April 11, 2023 | Volume: 29 | Issue: 12 | Pages: 1282-1291

10.1097/lvt.0000000000000156 Get It

In situ abdominal normothermic regional perfusion (A-NRP) has been used for liver transplantation (LT) with donation after circulatory death (DCD) liver grafts in Europe with excellent results; however, adoption of A-NRP in the United States has been lacking. The current report describes the implementation and results of a portable, self-reliant A-NRP program in the United States. Isolated abdominal in situ perfusion with an extracorporeal circuit was achieved through cannulation in the abdomen or femoral vessels and inflation of a supraceliac aortic balloon and cross-clamp. The Quantum Transport System by Spectrum was used. The decision to use livers for LT was made through an assessment of perfusate lactate (q15min). From May to November 2022, 14 A-NRP donation after circulatory death procurements were performed by our abdominal transplant team (N = 11 LT, N = 20 kidney transplants, and 1 kidney-pancreas transplant). The median A-NRP run time was 68 minutes. None of the LT recipients had post-reperfusion syndrome, nor were there any cases of primary nonfunction. All livers were functioning well at the time of maximal follow-up with zero cases of ischemic cholangiopathy. The current report describes the feasibility of a portable A-NRP program that can be used in the United States. Excellent short-term post-transplant results were achieved with both livers and kidneys procured from A-NRP.
Intraoperative management of a hybrid extracorporeal membrane oxygenation circuit for lung transplantation
Martin, Archer Kilbourne , Harrison, Barry, Fritz, Ashley Virginia , Landolfo, Kevin , Makey, Ian A., Sareyyüpoğlu, Başar , Brown, Thomas E. , Johnson, James L., Pham, Si M. , Thomas, Mathew , Thomas, Mathew , Harrison, Barry A, Landolfo, Kevin P, Thomas, Mathew , Pham, Si , Martin, Archer Kilbourne

Journal of Cardiac Surgery | September 17, 2020 | Volume: 35 | Issue: 12 | Pages: 3560-3563

10.1111/jocs.15029 Get It

Intraoperative Management of a Hybrid Extracorporeal Membrane Oxygenation Circuit for Lung Transplantation
Harrison, Barry, Landolfo, Kevin , Makey, Ian A., Sareyyüpoğlu, Başar , Brown, Thomas E. , Johnson, James L., Thomas, Mathew , Martin, Archer Kilbourne , Fritz, Ashley Virginia , Pham, Si M.

No container title available | August 17, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159769209.91814403 Get It

The use of extracorporeal circulation (ECC) for intraoperative cardiopulmonary support during lung transplantation has been increasing in the recent years. Our group previously described a novel hybrid extracorporeal membrane oxygenation (ECMO) circuit for use in lung transplantation. Our novel technique for intraoperative management of this circuit during lung transplantation is described.
Lung Transplantation Using a Hybrid Extracorporeal Membrane Oxygenation Circuit
Thomas, Mathew , Allen, Wesley L. , Makey, Ian A., Rodrigues, Eduardo , Mordecai, Monica, Brown, Thomas E. , Foeks, Jeremy J., Johnson, James L., Landolfo, Kevin, Thomas, Mathew , Martin, Archer K, Rodrigues, Eduardo S, Mordecai, Monica M, Landolfo, Kevin L, Pham, Si M. , Thomas, Mathew , Martin, Archer Kilbourne , Renew, J. Ross , Landolfo, Kevin

ASAIO Journal | March 30, 2020 | Volume: 66 | Issue: 10 | Pages: e123-e125

10.1097/mat.0000000000001157 Get It

Extracorporeal circulation (ECC) support using intraoperative extracorporeal membrane oxygenation (ECMO) during lung transplantation (LTx) is now a routine practice for many high volume centers. Circuits that are dedicated to ECMO alone can be expensive and do not allow full cardiopulmonary bypass (CPB) to be performed. We describe our technique of instituting venoarterial ECMO during LTx using a less-expensive hybrid circuit that facilitates easy and immediate conversion to full CPB if needed, without interruption of ECC.