Implant removal and synovectomy were used to treat the failure of 14 first metatarsophalangeal joint implant arthroplasties. Revision surgery was performed at an average of 3.1 years after arthroplasty. Follow-up (average 4.9 years) was possible in 10 patients, and clinical results were excellent in seven patients, good in one patient, fair in one patient, and poor in one patient. No significant changes in alignment occurred, although a trend toward toe extension was noted. Dynamic force plate studies in these patients demonstrated less pressure under the first metatarsal head and greater loading under the lateral forefoot. The great toe had less contact time during gait in the involved feet than in the control feet.
Biomechanics of the golf swing in players with pathologic conditions of the forearm, wrist, and hand
Golf is an activity generally stressful to the hands and wrists and particularly can produce increasing symp toms in players with underlying problems such as hand and wrist arthritis or tendinitis. The purpose of this study was to quantitate wrist motion and club head/ ball impact force in subjects with pathologic conditions of the hand, wrist, or forearm, within a laboratory environment. A regular straight-handled golf club was compared to a new BioCurve handle design that has a 19° ulnar bend. We measured and compared the effect of the two grips on wrist motion, club head velocity, ball impact force, ball impact location, and isometric torsional strength in 20 subjects who had a variety of upper extremity disorders. This data was then com pared to data collected in an identical fashion from golfers without such conditions. The results of our study show that there were no differences related to club handle design on impact force or impact location, club head velocity, or club head path and face angle. Wrist kinematic differences were minimal between handle designs. The differences that were significant (P < 0.05) centered around the decreased ulnar deviation of the left hand that resulted when subjects used the BioCurve handle design, which also allowed greater resistance to torque than the straight grip club. In addition to collecting objective data, we asked subjects for their opinions of the two grips. As a whole, the normal group and the group with pathologic conditions noted more comfort, improved grip, and less shock transmission with the BioCurve handle.
Isometric and isokinetic endurance testing of the forearm complex
The purpose of this study was to investigate the rela tionship of isometric and isokinetic endurance of the forearm complex under maximum effort in a healthy population. Isometric and isokinetic endurance meas urements of elbow flexion and extension of the domi nant and nondominant sides were made in 32 healthy male subjects (age range, 21 to 39 years). Both fatigue rates and the amount of time elapsed in reaching fatigue were determined. Analysis of these data reveals that 1) isometric endurance of the forearm complex cannot be used as a predictor of isokinetic endurance, as there is no relationship between the two, 2) dominant and non dominant endurance are related, a result that supports the belief that in the assessment of the endurance of a single diseased upper extremity, the best available comparison is with the contralateral healthy extremity, and 3) healthy males in the age range tested have greater endurance in elbow extension than in flexion.
The relationship of strength and jump height in figure skaters
Eighteen junior elite figure skaters were filmed while performing axel and double axel jumps. These same skaters were assessed for strength of the shoulders, knees, and hips at multiple angular velocities using a Cybex II system. The height of the jumps was signifi cantly correlated with the strength data. Knee exten sion at 240 deg/sec and shoulder abduction at 300 deg/sec were shown to be the most important strength parameters in determining the height of the jump. This information may be useful for designing strength train ing programs for figure skaters.