Evaluations of UltraiQ software for objective ultrasound image quality assessment using images from a commercial scanner
Long, Zaiyang , Tradup, Donald J., Stekel, Scott F. , Gorny, Krzysztof R. , Hangiandreou, Nicholas J.

Journal of Applied Clinical Medical Physics | January 16, 2018 | Volume: 19 | Issue: 2 | Pages: 298-304

10.1002/acm2.12255 Get It

AbstractWe evaluated a commercially available software package that uses B‐mode images to semi‐automatically measure quantitative metrics of ultrasound image quality, such as contrast response, depth of penetration (DOP), and spatial resolution (lateral, axial, and elevational). Since measurement of elevational resolution is not a part of the software package, we achieved it by acquiring phantom images with transducers tilted at 45 degrees relative to the phantom. Each measurement was assessed in terms of measurement stability, sensitivity, repeatability, and semi‐automated measurement success rate. All assessments were performed on a GE Logiq E9 ultrasound system with linear (9L or 11L), curved (C1‐5), and sector (S1‐5) transducers, using a CIRS model 040GSE phantom. In stability tests, the measurements of contrast, DOP, and spatial resolution remained within a ±10% variation threshold in 90%, 100%, and 69% of cases, respectively. In sensitivity tests, contrast, DOP, and spatial resolution measurements followed the expected behavior in 100%, 100%, and 72% of cases, respectively. In repeatability testing, intra‐ and inter‐individual coefficients of variations were equal to or less than 3.2%, 1.3%, and 4.4% for contrast, DOP, and spatial resolution (lateral and axial), respectively. The coefficients of variation corresponding to the elevational resolution test were all within 9.5%. Overall, in our assessment, the evaluated package performed well for objective and quantitative assessment of the above‐mentioned image qualities under well‐controlled acquisition conditions. We are finding it to be useful for various clinical ultrasound applications including performance comparison between scanners from different vendors.
Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems
Favazza, Christopher , Fetterly, Kenneth A. , Hangiandreou, Nicholas J., Schueler, Beth A. , Favazza, Christopher P, Leng, Shuai , Leng, Shuai

Journal of Medical Imaging | March 26, 2015 | Volume: 2 | Issue: 1 | Pages: 015503

10.1117/1.jmi.2.1.015503 Get It

The effect of magnification on sonographically measured nerve cross‐sectional area
Jelsing, Elena J., Presley, James C., Maida, Eugene , Hangiandreou, Nicholas J., Smith, Jay

Muscle & Nerve | May 3, 2014 | Volume: 51 | Issue: 1 | Pages: 30-34

10.1002/mus.24274 Get It

ABSTRACTIntroduction: The primary aim of this investigation was to determine whether use of write‐zoom magnification affects sonographically determined cross‐sectional area (CSA) of peripheral nerves. Methods: CSAs of the median (MN) and posterior interosseous (PIN) nerves were measured in 22 limbs from 11 asymptomatic volunteers using both standard imaging and write‐zoom magnification. CSA measurements were repeated on the same images 1 week later. Results: The average CSA of write‐zoomed images for the MN was significantly larger at both measurement sessions (week 1: 11.1 mm2 write‐zoom vs. 10.0 mm2 standard, P = 0.019; week 2: 11.8 mm2 vs. 10.4 mm2, P = 0.023). Similar differences were noted for the PIN (week 1: 2.3 mm2 vs. 1.9 mm2, P = 0.002; week 2: 2.5 mm2 vs. 1.9 mm2, P = 0.001). Conclusions: Write‐zoom magnification may significantly increase the measured CSA of peripheral nerves. These changes appear to be more substantial when smaller nerves are measured. Muscle Nerve 51: 30–34, 2015
Comparison of ultrasound quality assurance phantom measurements from matched and mixed scanner‐transducer combinations
Tradup, Donald J., Hangiandreou, Nicholas J., Taubel, Jerome P.

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 4 | Issue: 3 | Pages: 239-247

10.1120/jacmp.v4i3.2521 Get It

Our goal in this work was to compare the results of common phantom tests made using matched and mixed ultrasound (US) scanner‐transducer combinations. Sets of common US quality assurance (QA) measurements were made using matched US scanner‐transducer combinations (i.e., transducers purchased for use with a particular scanner), as well as unmatched (mixed) combinations. Measurements of vertical and horizontal distance accuracy, and depth of penetration were performed using three common transducer types. Means, standard deviations, and differences between the mean mix and match measurements divided by the standard deviation (match‐mix difference, or MMD), and two‐sided, paired t‐tests were computed for the groups of mixed and matched measurements. MMDs for vertical and horizontal distance accuracy test results were less than 0.87 in all cases, well below our threshold value of 2.0, which indicates that a significant difference exists. MMDs for the depth of penetration measurements were less than 1.50, again below the threshold value. These results suggest that all of the mixed and matched data sets were very similar. The more sensitive t‐tests indicate statistically significant differences in only 2 of the 18 pairs of data sets. In conclusion, this study suggests that QA measurements generated by mixed or matched scanner‐transducer combinations are very comparable. The ability to obtain QA phantom test data from mixed scanner‐transducer combinations reduces the time required for US QA testing.PACS number(s): 87.57.–s, 87.62.+n